Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 33Optical Imaging and Spectroscopy TechniquesCardiovascular and exercise physiologyInfrared Thermography in Medicine

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Detection of changes in muscle oxygen saturation in the human leg: a comparison of two near-infrared spectroscopy devices

Nygren, Andreas, Rennerfelt, Kajsa, Zhang, Qiuxia·2014·Journal of Clinical Monitoring and Computing

Abstract

The purpose of this study was first to evaluate the near infrared spectroscopy (NIRS) device, INVOS 4100 as a method of measuring exercise and arterial occlusion induced muscle ischemia in human leg, by comparison with InSpectra tissue spectrometer Model 325, and secondly to determine the influence of skin and subcutaneous thickness on the NIRS measurements. Twenty healthy subjects (43 ± 8 years) volunteered for the study. Tissue oxygen saturation (StO2) in the anterior tibial muscle was measured simultaneously with InSpectra Model 325 in one leg and INVOS 4100 in the contralateral leg during an exercise test until muscle exhaustion and arterial occlusion with and without exercise. The skin and subcutaneous thickness was identified by ultrasound imaging. Baseline StO2 was 87 ± 8 % detected by InSpectra and 76 ± 6 % by INVOS. Both devices detected an immediate decrease of StO2 (p < 0.001) during exercise, arterial occlusion with and without exercise, and a significant post ischemic hyperaemia (p < 0.001) during recovery. There was a significant inverse correlation between skin and subcutaneous thickness and baseline StO2 (r = -0.78, p < 0.01) as well as change in StO2 during exercise (r = -0.65, p = 0.002) for InSpectra, which was not apparent for INVOS. The results demonstrate that the cerebral/somatic oxygenation monitor (INVOS) is able to detect experimentally induced skeletal muscle ischemia in the human leg as well as the peripheral tissue spectrometer (InSpectra). Muscle…

Overview

Integrity signals

Registry

Crossref · 10.1007/s10877-013-9494-x

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Metadata

Authors
Nygren, A., Rennerfelt, K., & Zhang, Q.
Affiliations
Sahlgrenska University Hospital (SE)
Corresponding author
Nygren, Andreas
Venue
Journal of Clinical Monitoring and Computing
Published
2013-07-12
Volume
28
Issue
1
Pages
57-62
ISSN
  • 1387-1307 (ISSN-L)
  • 1573-2614
OpenAlex
W2071134130
Cited by
33
References
23
Citations by year
2026: 1 · 2025: 4 · 2024: 3 · 2023: 2 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 5 · 2018: 2 · 2017: 2 · 2016: 6 · 2015: 2 · 2014: 3
FWCI
2.84
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Journal of Clinical Monitoring and Computing (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
Keywords
near-infrared spectroscopy, muscle oxygen saturation, skeletal muscle ischemia, arterial occlusion, physical activity, tibial muscle, skin thickness, device comparison
MeSH terms
Adult, Arteries, Blood Pressure, Exercise Test, Female, Humans, Ischemia, Leg, Male, Middle Aged, Muscles, Oximetry, Oxygen, Oxygen Consumption, Skin, Cohort Studies, Exercise, Body Mass Index, Muscle, Skeletal, Spectroscopy, Near-Infrared

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.