Evaluation of different near-infrared spectroscopy technologies for assessment of tissue oxygen saturation during a vascular occlusion test
The DOI matches its Crossref record; 16 of the 17 references it cites were found in a registry or an index.
Abstract
An increasing number of NIRS devices are used to provide measurements of peripheral tissue oxygen saturation (S t O 2 ). The aim of the present study is to test the hypothesis that despite technological differences between devices, similar trend values will be obtained during a vascular occlusion test. The devices compared are NIRO-200NX, which measures S t O 2 and oxyhemoglobin by spatially resolved spectroscopy and the Beer-Lambert law, respectively, and INVOS 5100C and Foresight Elite, which both measure S t O 2 with the Beer-Lambert law, enhanced with the spatial resolution technique. Forty consenting adults scheduled for CABG surgery were recruited. The respective sensors of the three NIRS devices were applied over the brachioradial muscle. Before induction of anesthesia, 3 min of ischemia were induced by inflating a blood pressure cuff at the upper arm, whereafter cuff pressure was rapidly released. Tissue oxygenation measurements included baseline, minimum and maximum values, desaturation and resaturation slopes, and rise time. Comparisons between devices were performed with the Kruskal-Wallis test with post hoc Mann-Whitney pairwise comparisons. Agreement was evaluated using Bland-Altman plots. Oxyhemoglobin measured with NIRO responded faster than the other NIRS technologies to changes in peripheral tissue oxygenation (20 vs. 27-40 s, p ≤ 0.01). When comparing INVOS with Foresight, oxygenation changes were prompter (upslope 311 [92-523]%/min vs. 114[65-199]%/min, p ≤…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the same cannot be assumed between devices using SR methods, given the variety of algorithms in use, 22”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [22]
In the citing paper
“This contrasts with a recent study measuring TSI following 3 min arterial occlusion comparing in older adult patients ( 66 9 year) scheduled for elective coronary artery bypass grafting surgery. 22 In these older patients, 3 min occlusion was not enough to decrease TSI to a stable fixed baseline, probably due to a decrease in muscle oxygen consumption in this group compared to ours.”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [22]
In the citing paper
“However, the larger dynamic range reported by the MOXY ( Δ 74.3% ) surpasses that of alternative SR devices such as the FORE-SIGHT elite ( Δ 46% ) and INVOS5100C ( Δ 36% ). 22”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [22]
In the citing paper
“The minimum and maximum raw TSI values reported for the PortaMon ( Δ 43.7% ) are similar to that previously reported for the NIRO 200-NX 22,50 following an arterial occlusion applied at the upper arm ( Δ 33% ).”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [50]
In the citing paper
“The minimum and maximum raw TSI values reported for the PortaMon ( Δ 43.7% ) are similar to that previously reported for the NIRO 200-NX 22,50 following an arterial occlusion applied at the upper arm ( Δ 33% ).”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [22]
Citations
Cites
Scheeren, T. W. L., Schober, P., & Schwarte, L. A. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9348-y · Cited by 478
Postischemic vasodilation in human forearm is dependent on endothelium-derived nitric oxide
Meredith, I. T., Currie, K. E., Anderson, T. J., Roddy, M. A., Ganz, P., & Creager, M. A. (1996) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1996.270.4.h1435 · Cited by 281
Bezemer, R., Lima, A., Myers, D., Klijn, E., Heger, M., Goedhart, P. T., Bakker, J., & Ince, C. (2009) · Critical Care · doi:10.1186/cc8002 · Cited by 103
Hyttel-Sorensen, S., Sorensen, L. C., Riera, J., & Greisen, G. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.003047 · Cited by 92
Near-infrared spectroscopy (NIRS) monitoring in contemporary anesthesia and critical care.
Moerman, A., & Wouters, P. (2010) · PubMed · Cited by 72
Self-citationHyttel-Sørensen, S., Lawaetz, T. W. H., & Greisen, G. O. (2013) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-013-9507-9 · Cited by 72
Moerman, A., Vandenplas, G., Bové, T., Wouters, P. F., & Hert, S. G. D. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes375 · Cited by 69
Self-citationMansouri, C., L’Huillier, J.-P., Kashou, N. H., & Humeau‐Heurtier, A. (2010) · Lasers in Medical Science · doi:10.1007/s10103-010-0754-4 · Cited by 63
Messere, A., & Roatta, S. (2013) · Physiological Reports · doi:10.1002/phy2.179 · Cited by 63
Regional tissue oxygen saturation: comparability and reproducibility of different devices
Pocivalnik, M., Pichler, G., Zotter, H., Tax, N., Müller, W., & Urlesberger, B. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3575647 · Cited by 62
Cited by
McManus, C. J., Collison, J., & Cooper, C. E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.1.015007 · Cited by 205
Near-Infrared Spectroscopy in Adult Cardiac Surgery Patients: A Systematic Review and Meta-Analysis
Chan, M. J., Chung, T., Glassford, N. J., & Bellomo, R. (2017) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2017.02.187 · Cited by 92
Electroencephalography and Brain Oxygenation Monitoring in the Perioperative Period
Scheeren, T., Kuizenga, M. H., Mäurer, H., Struys, M. M. R. F., & Heringlake, M. (2018) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000002812 · Cited by 79
Kanick, S. C., Schneider, P. A., Klitzman, B. M., Wisniewski, N. A., & Rebrin, K. (2019) · Microvascular Research · doi:10.1016/j.mvr.2019.02.002 · Cited by 52
“, 2018), and to compare the performance of devices that measured hemoglobin oxygen saturation (Chien et al., 2017; Steenhaut et al., 2017).”
BackgroundKovácsová, Z., Bale, G. M., Mitra, S., Lange, F., & Tachtsidis, I. (2021) · Biomedical Optics Express · doi:10.1364/boe.412088 · Cited by 35
“Differences were found in the dynamic range of instruments [22], in the absolute changes in StO2 [23] and their response time [24].”
BackgroundNiezen, C. K., Massari, D., Vos, J. J., & Scheeren, T. (2022) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-021-00779-w · Cited by 26
“The INVOS NIRS device (Covidien, Mansfield, MA, USA) showed a higher DA and RA compared to the Foresight NIRS device (CAS Medical Systems, Branford, CT, USA, currently Edwards Lifesciences, Irvine, CA, USA) before anesthesia induction [33].”
MethodNear-Infrared Spectroscopy in Adult Circulatory Shock: A Systematic Review
Varis, E., Pettilä, V., & Wilkman, E. (2020) · Journal of Intensive Care Medicine · doi:10.1177/0885066620907307 · Cited by 25
Cortese, L., Zanoletti, M., Karadeniz, U., Pagliazzi, M., Yaqub, M. A., Busch, D. R., Mesquida, J., & Durduran, T. (2021) · Sensors · doi:10.3390/s21216957 · Cited by 26
Ferraris, A., Jacquet‐Lagrèze, M., & Fellahi, J.-L. (2017) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-017-0025-z · Cited by 23
“These dynamic indices markedly differed between male and female [19] and also when they are calculated with different NIRS devices [7, 16].”
BackgroundRobu, C. B., Koninckx, A., Docquier, M.-A., Grosu, I., de Kerchove, L., Mastrobuoni, S., & Momeni, M. (2020) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2020.06.025 · Cited by 23
Ubbink, R., Bettink, M. A. W., van Weteringen, W., & Mik, E. G. (2020) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-020-00602-y · Cited by 18
The vascular occlusion test using multispectral imaging: a validation study
Bruins, A. A., Geboers, D. G. P. J., Bauer, J. R., Klaessens, J. H. G. M., Verdaasdonk, R. M., & Boer, C. (2020) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00448-z · Cited by 19
Leiva, K., Leizaola, D., Gonzalez, I., Dargam, V., Alirezaei, H., Kaile, K., Robledo, E. A., Hutcheson, J. D., & Godavarty, A. (2023) · Annals of Biomedical Engineering · doi:10.1007/s10439-023-03229-7 · Cited by 17
“Both devices could image and measure the decrease in ∆StO2 during the occlusion cycle and the hyperemic reperfusion that commonly proceeds post-occlusion [12, 33].”
BackgroundVos, J. J., Ellermann, S. F., & Scheeren, T. (2019) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00270-7 · Cited by 15
Keuler, J., Weiß, C., Klemm, K., Pochhammer, J., Schmidt, R., & Ilies, C. (2018) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000871 · Cited by 13
Chung, J., Ji, S., Jang, Y., Kim, E., Lee, J., Kim, J., & Kim, H. (2020) · Journal of Vascular Research · doi:10.1159/000510072 · Cited by 12
Lee, J., Jang, Y., Song, I., Kim, E., Kim, H., & Kim, J. (2017) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000001386 · Cited by 15
Reliability of near-infrared spectroscopy in measuring muscle oxygenation during squat exercise
Corral‐Pérez, J., Marín-Galindo, A., Costilla, M., Casals, C., Muñoz‐López, A., Sixto, A. S., Sañudo, B., & Ponce‐González, J. G. (2024) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2024.07.006 · Cited by 14
Zdravković, M., Podbregar, M., & Kamenik, M. (2019) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00406-9 · Cited by 9
Endo, T., Kime, R., Fuse, S., Murase, N., Kurosawa, Y., & Hamaoka, T. (2020) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002530 · Cited by 8
Moerman, A., Vandenheuvel, M., Tuybens, P., GOMPEL, C. V., & Hert, S. G. D. (2021) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-021-00702-3 · Cited by 8
“compared three different NIRS measurement technologies, including MBL and SRS, during changes in peripheral tissue oxygenation induced by a vascular occlusion test [23].”
BackgroundMethodResultSelf-citationThiele, R. H., Ikeda, K., Osuru, H. P., & Zuo, Z. (2018) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000003572 · Cited by 6
Assessing stability and accuracy of a novel commercial wearable near-infrared spectroscopy device
de Moreira, I. D. M., Willigenburg, T. R., Kregting, W. J. W., Steijn, E. R. C. V., Floor, M., & Colier, W. N. J. M. (2023) · Biophotonics in Exercise Science, Sports Medicine, Health Monitoring Technologies, and Wearables · doi:10.1117/12.2657434 · Cited by 8
“The analysis of VOT was based on and modified from previous studies [24,25].”
MethodWu, W., Zheng, Q., Zhou, J., Li, X., & Zhou, H. (2024) · Medicine · doi:10.1097/md.0000000000037454 · Cited by 5
“[27] Although values obtained through different devices are not interchangeable, similar trends can be expected.”
BackgroundPerioperative hemodynamic monitoring techniques: a narrative review
Bouchez, S., Backer, D. D., Fraipont, V., Momeni, M., Rex, S., & Hert, S. G. D. (2024) · Acta Anaesthesiologica Belgica · doi:10.56126/75.2.40 · Cited by 8
Kinetics of tissue oxygenation index during fast and slow cardiopulmonary bypass initiation
Turra, J., Bauer, A., Möbius, A., Wojdyla, J., & Eisner, C. B. (2022) · Perfusion · doi:10.1177/02676591211068972 · Cited by 4
Kubo, R., Okamoto, T., & Haneishi, H. (2026) · Biomedical Optics Express · doi:10.1364/boe.596760 · Cited by 3
“Previous studies have reported discrepancies among commercial NIRS devices [14–17] as well as limited accuracy in phantom-based verification experiments [15–17]; therefore, obtaining reliable absolute StO 2 values remains challenging.”
Feldmann, A., Quaresima, V., Perrey, S., & Ferrari, M. (2026) · Sports Medicine - Open · doi:10.1186/s40798-026-01033-w · Cited by 2
“Interestingly, different dynamic ranges during forearm AOM were also observed with other commercial brain oximeters [103, 104].”
Evaluation of a low-cost portable NIRS device for monitoring muscle ischemia
Marrero-García, R., Cruz-Tabares, Y., González-Cava, J. M., Pérez, J. A. M., & Reboso, J. A. (2024) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-024-01226-2 · Cited by 2
“Previous studies have shown that the results obtained from different NIRS devices are not interchangeable and can differ significantly [16, 17].”
Sakaguchi, K., Saito, S., Takada, M., Takahashi, K., Onodera, Y., Kobayashi, T., Kawamae, K., & Nakane, M. (2024) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2025.06.051 · Cited by 2
Song, K., Xu, Q., Koenig, H. M., Kong, M., Slaughter, M. S., Huang, Y., Clifford, S. P., & Huang, J. (2020) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2020.10.043 · Cited by 4
Yang, H. W., & Gao, Q. (2025) · Thermal Science and Engineering Progress · doi:10.1016/j.tsep.2025.103466 · Cited by 1
RetractedHebden, J. C. (2026) · Biomedical Optics Express · doi:10.1364/boe.585939 · Cited by 1
“Following trends observed in several published estimates of the changes in concentrations of Hb, HbO 2 , and HbT during vascular occlusion [20,21,22], these parameters were modelled to vary over a period of 600 seconds as illustrated in Fig.”
Wang, S., Liu, Y., Liu, Y., Qian, Z., & Chen, Z. (2021) · Journal of Innovative Optical Health Sciences · doi:10.1142/s179354582250002x · Cited by 1
Measurement of tissue oxygen saturation during arthroscopic surgery of knee with a tourniquet
Hao, N., Cui, M., Shi, Y., Liu, Z., Li, X., Chen, Y., & Zhao, G. (2022) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-022-03431-8 · Cited by 1
Baseline regional cerebral oxygen saturation values in a cohort of elderly surgical patients
Dias, M. P. C. T. (2020) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/gn80-pt95
Mizunoya, K., Yagi, Y., Morimoto, Y., & Hirano, S. (2021) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-021-00697-x
“Although several types of commercially available NIRS instruments can be used, static and dynamic StO2 are not comparable between devices with different measurement principles and adopted number of wavelengths [34, 35].”
BackgroundMicrowave Ablation Efficacy Evaluation of Bone Tissue Based on Near Infrared SpectrumPreprint
Liu, Y., Zhou, Y., Meng, L., Qian, Z., Li, W., Lu, S., & Chen, Y. (2020) · doi:10.21203/rs.3.rs-96926/v1
Dietze, Z., von ASPERN, K., Haunschild, J., Oßmann, S., Borger, M. A., & Etz, C. D. (2022) · Research Square · doi:10.21203/rs.3.rs-1728216/v1
Wang, S., Chen, Z., Liu, Y., Liu, Y., Qian, Z., & Meng, L. (2023) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22942
Şavluk, Ö. F., Yılmaz, A. A., Tomrukçu, F., Yavuz, Y., Işıldak, F. U., Genç, F. A., Arıcı, Ş., Karakuş, Ö. S., Corbacioglu, S., Gürcü, M. E., et al. (2026) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2026.05.001
A Multi-Model Analysis of Non-Invasive Oxygen Saturation from Smartphone-Captured Fingertip Video
Sabith, N. U. S., Ahamad, M. M., Arefin, K. Z., Rabbani, M., & Ahamed, S. I. (2026) · IEEE International Conference on Digital Health (ICDH) · doi:10.1109/icdh72779.2026.00022
“Transcutaneous oximetry [7], near-infrared spectroscopy [8], optoacoustic imaging [9], and resonance Raman spectroscopy [10] have been proposed by researchers, each serving a specific population.”
Metadata
- Authors
- Steenhaut, K., Lapage, K., Bové, T., De Hert, S., & Moerman, A.
- Affiliations
- Ghent University Hospital (BE)
- Venue
- Journal of Clinical Monitoring and Computing
- Published
- 2016-11-22
- Volume
- 31
- Issue
- 6
- Pages
- 1151-1158
- ISSN
- 1387-1307 (ISSN-L)
- 1573-2614
- OpenAlex
- W2557093061
- Semantic Scholar
- 9df3c1c42230a81a4fbb35c0fdb0467019180538
- Cited by
- 41
- References
- 17
- Citations by year
- 2026: 5 · 2025: 1 · 2024: 5 · 2023: 3 · 2022: 4 · 2021: 4 · 2020: 9 · 2019: 3 · 2018: 4 · 2017: 3
- FWCI
- 2.90
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Clinical Monitoring and Computing (publishedVersion)
- PubMed (publishedVersion)
- Ghent University Academic Bibliography (Ghent University) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Keywords
- near-infrared spectroscopy, tissue oxygen saturation, vascular occlusion test, peripheral tissue oxygenation, device comparison, spatially resolved spectroscopy, Beer-Lambert law, ischemia, coronary artery bypass grafting
- MeSH terms
- Aged, Female, Humans, Ischemia, Male, Middle Aged, Oximetry, Oxygen, Oxygen Consumption, Prospective Studies, Signal Processing, Computer-Assisted, Vascular Diseases, Muscle, Skeletal, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.