Evaluation of different near-infrared spectroscopy technologies for assessment of tissue oxygen saturation during a vascular occlusion test

Steenhaut, Kevin, Lapage, Koen, Bové, Thierry, De Hert, Stefan, Moerman, Annelies · 2017 · Journal of Clinical Monitoring and Computing

The DOI matches its Crossref record; 16 of the 17 references it cites were found in a registry or an index.

Abstract

An increasing number of NIRS devices are used to provide measurements of peripheral tissue oxygen saturation (S t O 2 ). The aim of the present study is to test the hypothesis that despite technological differences between devices, similar trend values will be obtained during a vascular occlusion test. The devices compared are NIRO-200NX, which measures S t O 2 and oxyhemoglobin by spatially resolved spectroscopy and the Beer-Lambert law, respectively, and INVOS 5100C and Foresight Elite, which both measure S t O 2 with the Beer-Lambert law, enhanced with the spatial resolution technique. Forty consenting adults scheduled for CABG surgery were recruited. The respective sensors of the three NIRS devices were applied over the brachioradial muscle. Before induction of anesthesia, 3 min of ischemia were induced by inflating a blood pressure cuff at the upper arm, whereafter cuff pressure was rapidly released. Tissue oxygenation measurements included baseline, minimum and maximum values, desaturation and resaturation slopes, and rise time. Comparisons between devices were performed with the Kruskal-Wallis test with post hoc Mann-Whitney pairwise comparisons. Agreement was evaluated using Bland-Altman plots. Oxyhemoglobin measured with NIRO responded faster than the other NIRS technologies to changes in peripheral tissue oxygenation (20 vs. 27-40 s, p ≤ 0.01). When comparing INVOS with Foresight, oxygenation changes were prompter (upslope 311 [92-523]%/min vs. 114[65-199]%/min, p ≤…

Overview

Integrity signals

Registry

Crossref · 10.1007/s10877-016-9962-1

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 16 references

Cited by

See all 42

Metadata

Authors
Steenhaut, K., Lapage, K., Bové, T., De Hert, S., & Moerman, A.
Affiliations
Ghent University Hospital (BE)
Venue
Journal of Clinical Monitoring and Computing
Published
2016-11-22
Volume
31
Issue
6
Pages
1151-1158
ISSN
  • 1387-1307 (ISSN-L)
  • 1573-2614
OpenAlex
W2557093061
Cited by
41
References
17
Citations by year
2026: 5 · 2025: 1 · 2024: 5 · 2023: 3 · 2022: 4 · 2021: 4 · 2020: 9 · 2019: 3 · 2018: 4 · 2017: 3
FWCI
2.90
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Clinical Monitoring and Computing (publishedVersion)
  • PubMed (publishedVersion)
  • Ghent University Academic Bibliography (Ghent University) (submittedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
Keywords
near-infrared spectroscopy, tissue oxygen saturation, vascular occlusion test, peripheral tissue oxygenation, device comparison, spatially resolved spectroscopy, Beer-Lambert law, ischemia, coronary artery bypass grafting
MeSH terms
Aged, Female, Humans, Ischemia, Male, Middle Aged, Oximetry, Oxygen, Oxygen Consumption, Prospective Studies, Signal Processing, Computer-Assisted, Vascular Diseases, Muscle, Skeletal, Spectroscopy, Near-Infrared

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.