Is quantitative pupillometry affected by ambient light? A prospective crossover study
The DOI matches its Crossref record.
Abstract
Purpose: Pupillary examination is a central part of the neurological assessment. While quantitative pupillometry (QP) improves reliability, the impact of ambient light, particularly on the Neurological Pupil index (NPi), remains unclear. This study aimed to clarify the effects of ambient light on QP parameters in a critical care setting. Methods: We performed a prospective crossover study, including 20 adult patients requiring invasive ventilation. Pupillometry was performed during bright condition (BC1), then dark condition (DC), then bright condition again (BC2). In our primary analysis we compared NPi values across conditions (DC1 vs. BC, BC vs. DC2, DC1 vs. DC2). In the secondary analysis, we compared all other QP parameters. Results: All QP values except constriction velocity and dilation velocity were non-normal. The median NPi was significantly lower in BC compared to dark conditions DC1 in both eyes. In 25% of participants the NPi decreased by 0.6 or more. Conversely, a significant increase in median NPi of both eyes was observed when switching from bright conditions back to dark (BC vs. DC2). No significant difference was found between the two dark condition measurements (DC1 and DC2). The secondary analysis showed that the differences in NPi were driven by differences in most, but not all, QP parameters included in NPi. Conclusions: We corroborate previous findings that the level of ambient light affects QP parameters in critically ill patients. This needs to be considered for accurate interpretation of QP parameters. Future studies may explore potential automated light correction methods for wider clinical applicability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Factors affecting the accuracy of manual pupil assessment include the intensity of the light source used, ambient lighting conditions, the experience of the evaluator, and the patient's gaze position during the assessment (14,33).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [33]
In the citing paper
“One study demonstrated that ambient light exerts significant effects on NPi and other pupillometric parameters, underscoring the necessity of standardized lighting conditions during interpretation (33).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [33]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 48
- Bower MM, Sweidan AJ, Xu JC, Stern-Neze S, Yu W, Groysman LI. Quantitative pupillometry in the intensive care unit. J Intensive Care Med. 2021;36:383–91. https://doi.org/10.1177/0885066619881124. · doi:10.1177/0885066619881124
- Morelli P, Oddo M, Ben-Hamouda N. Role of automated pupillometry in critically ill patients. Minerva Anestesiol. 2019;85:995–1002. https://doi.org/10.23736/S0375-9393.19.13437-2. · doi:10.23736/s0375-9393.19.13437-2
- Couret D, Boumaza D, Grisotto C, Triglia T, Pellegrini L, Ocquidant P, Bruder NJ, Velly LJ. Reliability of standard pupillometry practice in neurocritical care: an observational, double-blinded study. Crit Care Lond Engl. 2016;20:99. https://doi.org/10.1186/s13054-016-1239-z. · DOI · Paper page
- Chen JW, Gombart ZJ, Rogers S, Gardiner SK, Cecil S, Bullock RM. Pupillary reactivity as an early indicator of increased intracranial pressure: the introduction of the neurological pupil index. Surg Neurol Int. 2011;2:82. https://doi.org/10.4103/2152-7806.82248. · DOI · Paper page
- Ong C, Hutch M, Smirnakis S. The effect of ambient light conditions on quantitative pupillometry. Neurocrit Care. 2019;30:316–21. https://doi.org/10.1007/s12028-018-0607-8. · DOI · Paper page
- Kelbsch C, Strasser T, Chen Y, Feigl B, Gamlin PD, Kardon R, Peters T, Roecklein KA, Steinhauer SR, Szabadi E, Zele AJ, Wilhelm H, Wilhelm BJ. Standards in pupillography. Front Neurol. 2019;10:129. https://doi.org/10.3389/fneur.2019.00129. · DOI · Paper page
- Couret D, Simeone P, Freppel S, Velly L. The effect of ambient-light conditions on quantitative pupillometry: a history of rubber cup. Neurocrit Care. 2019;30:492–3. https://doi.org/10.1007/s12028-018-0664-z. · doi:10.1007/s12028-018-0664-z
- Martínez-Palacios K, Vásquez-García S, Fariyike OA, Robba C, Rubiano AM, noninvasive intracranial pressure monitoring international consensus group. Quantitative pupillometry for intracranial pressure (ICP) monitoring in traumatic brain injury: A scoping review. Neurocrit Care. 2024;41:255–71. https://doi.org/10.1007/s12028-023-01927-7. · DOI
- Giede-Jeppe A, Sprügel MI, Huttner HB, Borutta M, Kuramatsu JB, Hoelter P, Engelhorn T, Schwab S, Koehn J. Automated pupillometry identifies absence of intracranial pressure elevation in intracerebral hemorrhage patients. Neurocrit Care. 2021;35:210–20. https://doi.org/10.1007/s12028-020-01146-4. · DOI
- Stevens AR, Su Z, Toman E, Belli A, Davies D. Optical pupillometry in traumatic brain injury: neurological pupil index and its relationship with intracranial pressure through significant event analysis. Brain Inj. 2019;33:1032–8. https://doi.org/10.1080/02699052.2019.1605621. · DOI
- McNett M, Moran C, Grimm D, Gianakis A. Pupillometry trends in the setting of increased intracranial pressure. J Neurosci Nurs J Am Assoc Neurosci Nurses. 2018;50:357–61. https://doi.org/10.1097/JNN.0000000000000401. · doi:10.1097/jnn.0000000000000401
- McNett M, Moran C, Janki C, Gianakis A. Correlations between hourly pupillometer readings and intracranial pressure values. J Neurosci Nurs J Am Assoc Neurosci Nurses. 2017;49:229–34. https://doi.org/10.1097/JNN.0000000000000290. · doi:10.1097/jnn.0000000000000290
- Ali AMS, Gul W, Sen J, Hewitt S-J, Olubajo F, McMahon C. Evaluating the utility of quantitative pupillometry in a neuro-critical care setting for the monitoring of intracranial pressure: A prospective cohort study. Clin Neurol Neurosurg. 2024;239:108215. https://doi.org/10.1016/j.clineuro.2024.108215. · DOI
- Pansell J, Hack R, Rudberg P, Bell M, Cooray C. Can quantitative pupillometry be used to screen for elevated intracranial pressure?? A retrospective cohort study. Neurocrit Care. 2022;37:531–7. https://doi.org/10.1007/s12028-022-01518-y. · doi:10.1007/s12028-022-01518-y
- Robba C, Picetti E, Vásquez-García S, Abulhasan YB, Ain A, Adeleye AO, Aries M, Brasil S, Badenes R, Bertuccio A, Bouzat P, Bustamante L, Calabro’ L, Njimi H, Cardim D, Citerio G, Czosnyka M, Geeraerts T, Godoy DA, Hirzallah MI, Devi BI, Jibaja M, Lochner P, Mijangos Méndez JC, Meyfroidt G, Munusamy T, Portilla JP, Prabhakar H, Rasulo F, Sánchez Parra DM, Sarwal A, Shrestha GS, Shukla DP, Sung G, Tirsit A, Vásquez F, Videtta W, Wang YL, Paiva WS, Taccone FS, Rubiano AM. The Brussels consensus for non-invasive ICP monitoring when invasive systems are not available in the care of TBI patients (the B-ICONIC consensus, recommendations, and management algorithm). Intensive Care Med. 2025;51:4–20. https://doi.org/10.1007/s00134-024-07756-2. · DOI
- Aoun SG, Stutzman SE, Vo P-UN, El Ahmadieh TY, Osman M, Neeley O, Plitt A, Caruso JP, Aiyagari V, Atem F, Welch BG, White JA, Batjer HH, Olson DM. Detection of delayed cerebral ischemia using objective pupillometry in patients with aneurysmal subarachnoid hemorrhage. J Neurosurg. 2020;132:27–32. https://doi.org/10.3171/2018.9.JNS181928. · doi:10.3171/2018.9.jns181928
- Maxin AJ, Kush S, Gulek BG, Winston GM, Chae J, Shaibani R, McGrath LB, Abecassis IJ, Levitt MR. Smartphone pupillometry for detection of cerebral vasospasm after aneurysmal subarachnoid hemorrhage. J Stroke Cerebrovasc Dis Off J Natl Stroke Assoc. 2024;33:107922. https://doi.org/10.1016/j.jstrokecerebrovasdis.2024.107922. · doi:10.1016/j.jstrokecerebrovasdis.2024.107922
- Klug J, Martins J, De Trizio I, Carrera E, Filipovic M, Hostettler IC, Pietsch U. Dynamically normalized pupillometry for detecting delayed cerebral ischemia after aneurysmal subarachnoid hemorrhage. Crit Care Explor. 2024;6:e1135. https://doi.org/10.1097/CCE.0000000000001135. · DOI
- Gouvêa Bogossian E, Blandino Ortiz A, Esposito V, Caricato A, Righy Shinotsuka C, Monléon Lopez B, Giannì G, Macchini E, de Pablo Sanchez R, Pisapia L, Turon R, Gonçalves B, Badenes R, Kurtz P, Taccone FS. Neurological pupil index and delayed cerebral ischemia after subarachnoid hemorrhage: A retrospective multicentric study. Neurocrit Care. 2023;39:116–24. https://doi.org/10.1007/s12028-023-01744-y. · doi:10.1007/s12028-023-01744-y
- Nyholm B, Obling LER, Hassager C, Grand J, Møller JE, Othman MH, Kondziella D, Kjaergaard J. Specific thresholds of quantitative pupillometry parameters predict unfavorable outcome in comatose survivors early after cardiac arrest. Resusc Plus. 2023;14:100399. https://doi.org/10.1016/j.resplu.2023.100399. · DOI
- Peluso L, Oddo M, Minini A, Citerio G, Horn J, Di Bernardini E, Rundgren M, Cariou A, Payen J-F, Storm C, Stammet P, Sandroni C, Taccone FS. Neurological pupil index and its association with other prognostic tools after cardiac arrest: A post hoc analysis. Resuscitation. 2022;179:259–66. https://doi.org/10.1016/j.resuscitation.2022.07.030. · DOI
- Riker RR, Sawyer ME, Fischman VG, May T, Lord C, Eldridge A, Seder DB. Neurological pupil index and pupillary light reflex by pupillometry predict outcome early after cardiac arrest. Neurocrit Care. 2020;32:152–61. https://doi.org/10.1007/s12028-019-00717-4. · DOI · Paper page
- Paramanathan S, Grejs AM, Søreide E, Duez CHV, Jeppesen AN, Reinertsen ÅJ, Strand K, Kirkegaard H. Quantitative pupillometry in comatose out-of-hospital cardiac arrest patients: A post-hoc analysis of the TTH48 trial. Acta Anaesthesiol Scand. 2022;66:880–6. https://doi.org/10.1111/aas.14078. · doi:10.1111/aas.14078
- Thuccani M, Joelsson S, Lilja L, Strålin A, Nilsson J, Redfors P, Rawshani A, Herlitz J, Lundgren P, Rylander C. The capacity of neurological pupil index to predict the absence of somatosensory evoked potentials after cardiac arrest - An observational study. Resusc Plus. 2024;17:100567. https://doi.org/10.1016/j.resplu.2024.100567. · doi:10.1016/j.resplu.2024.100567
- Oddo M, Sandroni C, Citerio G, Miroz J-P, Horn J, Rundgren M, Cariou A, Payen J-F, Storm C, Stammet P, Taccone FS. Quantitative versus standard pupillary light reflex for early prognostication in comatose cardiac arrest patients: an international prospective multicenter double-blinded study. Intensive Care Med. 2018;44:2102–11. https://doi.org/10.1007/s00134-018-5448-6. · DOI · Paper page
- Nolan JP, Sandroni C, Böttiger BW, Cariou A, Cronberg T, Friberg H, Genbrugge C, Haywood K, Lilja G, Moulaert VRM, Nikolaou N, Mariero Olasveengen T, Skrifvars MB, Taccone F, Soar J. European resuscitation Council and European society of intensive care medicine guidelines 2021: Post-resuscitation care. Resuscitation. 2021;161:220–69. https://doi.org/10.1016/j.resuscitation.2021.02.012. · DOI · Paper page
- Lee S, Jung D-E, Park D, Kim TJ, Lee H-C, Bae J, Nam K, Jeon Y, Cho YJ. Intraoperative neurological pupil index and postoperative delirium and neurologic adverse events after cardiac surgery: an observational study. Sci Rep. 2023;13:13838. https://doi.org/10.1038/s41598-023-41151-z. · doi:10.1038/s41598-023-41151-z
- Yang E, Kreuzer M, Hesse S, Davari P, Lee SC, García PS. Infrared pupillometry helps to detect and predict delirium in the post-anesthesia care unit. J Clin Monit Comput. 2018;32:359–68. https://doi.org/10.1007/s10877-017-0009-z. · doi:10.1007/s10877-017-0009-z
- Favre E, Bernini A, Morelli P, Pasquier J, Miroz J-P, Abed-Maillard S, Ben-Hamouda N, Oddo M. Neuromonitoring of delirium with quantitative pupillometry in sedated mechanically ventilated critically ill patients. Crit Care Lond Engl. 2020;24:66. https://doi.org/10.1186/s13054-020-2796-8. · DOI
- Lapierre A, Proulx A, Gélinas C, Dollé S, Alexander S, Williamson D, Bernard F, Arbour C. Association between pupil light reflex and delirium in adults with traumatic brain injury: preliminary findings. J Neurosci Nurs J Am Assoc Neurosci Nurses. 2024;56:107–12. https://doi.org/10.1097/JNN.0000000000000763. · DOI
- Lukaszewicz A-C, Dereu D, Gayat E, Payen D. The relevance of pupillometry for evaluation of analgesia before noxious procedures in the intensive care unit. Anesth Analg. 2015;120:1297. https://doi.org/10.1213/ANE.0000000000000609. · DOI
- Charier D, Vogler M-C, Zantour D, Pichot V, Martins-Baltar A, Courbon M, Roche F, Vassal F, Molliex S. Assessing pain in the postoperative period: analgesia nociception indextmversus pupillometry. Br J Anaesth. 2019;123:e322–7. https://doi.org/10.1016/j.bja.2018.09.031. · DOI
- Gregoire C, Charier D, de Bergeyck R, Mouraux A, Van Ouytsel F, Lambert R, Zhou N, Lavand’homme P, Penaloza A, Pickering G. Comparison between pupillometry and numeric pain rating scale for pain assessments in communicating adult patients in the emergency department. Eur J Pain Lond Engl. 2023;27:952–60. https://doi.org/10.1002/ejp.2137. · DOI
- Yaman Gülper R, Reisli R, Arıcan Ş, Yosunkaya A, Tuncer Uzun S. Comparison of pupillometer, critical care pain observation scale, and vital findings in the evaluation of pain in intensive care patients without oral communication. Agri Agri Algoloji Derneginin Yayin Organidir J Turk Soc Algol. 2023;35:53–62. https://doi.org/10.14744/agri.2021.72246. · doi:10.14744/agri.2021.72246
- López de Audícana-Jimenez, de Aberasturi Y, Vallejo-De la Cueva A, Aretxabala-Cortajarena N, Quintano-Rodero A, Rodriguez-Nuñez C, Pelegrin-Gaspar PM, Gil-Garcia ZI, Margüello-Fernandez AA, Aparicio-Cilla L, Parraza-Diez N. Pupillary dilation reflex and behavioural pain scale: study of diagnostic test. Intensive Crit Care Nurs. 2023;74:103332. https://doi.org/10.1016/j.iccn.2022.103332. · DOI
- Vide S, Castro A, Correia R, Cabral T, Lima D, Nunes CS, Gambús P, Amorim P. Foreseeing postoperative pain in neurosurgical patients: pupillometry predicts postoperative pain ratings-an observational study. J Clin Monit Comput. 2021;35:1111–8. https://doi.org/10.1007/s10877-020-00570-3. · doi:10.1007/s10877-020-00570-3
- Tosi F, Gatto A, Capossela L, Ferretti S, Mancino A, Curatola A, Chiaretti A, Pulitanò S. Role of the pupillometer in the assessment of pain in the sedation of pediatric patients. Eur Rev Med Pharmacol Sci. 2021;25:6349–55. https://doi.org/10.26355/eurrev_202110_27008. · doi:10.26355/eurrev_202110_27008
- Eisenach JC, Curry R, Aschenbrenner CA, Coghill RC, Houle TT. Pupil responses and pain ratings to heat stimuli: reliability and effects of expectations and a conditioning pain stimulus. J Neurosci Methods. 2017;279:52–9. https://doi.org/10.1016/j.jneumeth.2017.01.005. · DOI
- Vlaenderen DV, Hans G, Saldien V, Wildemeersch D. Pupillary reflex dilation and pain index evaluation during general anesthesia using sufentanil: a double-blind randomized controlled trial. Pain Manag. 2022;12:931–41. https://doi.org/10.2217/pmt-2022-0027. · doi:10.2217/pmt-2022-0027
- Greer DM, Shemie SD, Lewis A, Torrance S, Varelas P, Goldenberg FD, Bernat JL, Souter M, Topcuoglu MA, Alexandrov AW, Baldisseri M, Bleck T, Citerio G, Dawson R, Hoppe A, Jacobe S, Manara A, Nakagawa TA, Pope TM, Silvester W, Thomson D, Al Rahma H, Badenes R, Baker AJ, Cerny V, Chang C, Chang TR, Gnedovskaya E, Han M-K, Honeybul S, Jimenez E, Kuroda Y, Liu G, Mallick UK, Marquevich V, Mejia-Mantilla J, Piradov M, Quayyum S, Shrestha GS, Su Y-Y, Timmons SD, Teitelbaum J, Videtta W, Zirpe K, Sung G. Determination of brain death/death by neurologic criteria: the world brain death project. JAMA. 2020;324:1078–97. https://doi.org/10.1001/jama.2020.11586. · DOI · Paper page
- Lussier BL, Stutzman SE, Atem F, Venkatachalam AM, Perera AC, Barnes A, Aiyagari V, Olson DM. Distributions and reference ranges for automated pupillometer values in neurocritical care patients. J Neurosci Nurs. 2019;51:335. https://doi.org/10.1097/JNN.0000000000000478. · doi:10.1097/jnn.0000000000000478
- Olson DM, Stutzman SE, Atem F, Kincaide JD, Ho T-T, Carlisle BA, Aiyagari V. Establishing normative data for pupillometer assessment in neuroscience intensive care: the END-PANIC registry. J Neurosci Nurs. 2017;49:251. https://doi.org/10.1097/JNN.0000000000000296. · doi:10.1097/jnn.0000000000000296
- Robba C, Pozzebon S, Moro B, Vincent J-L, Creteur J, Taccone FS. Multimodal non-invasive assessment of intracranial hypertension: an observational study. Crit Care Lond Engl. 2020;24:379. https://doi.org/10.1186/s13054-020-03105-z. · DOI
- Asakawa K, Ito A, Kobayashi H, Iwai A, Ito C, Ishikawa H. Adaptation time, electroretinography, and pupillography in healthy subjects. Doc Ophthalmol. 2019;139:33–44. https://doi.org/10.1007/s10633-019-09693-8. · DOI
- Won S-Y, Dubinski D, Hagemeier J, Behmanesh B, Trnovec S, Bernstock JD, Freiman TM, Gessler F. Intracranial pressure monitoring in posterior fossa lesions-systematic review and meta-analysis. Neurosurg Rev. 2022;45:1933–9. https://doi.org/10.1007/s10143-022-01746-y. · doi:10.1007/s10143-022-01746-y
- Maxin AJ, Gulek BG, Lee C, Lim D, Mariakakis A, Levitt MR, McGrath LB. Validation of a smartphone pupillometry application in diagnosing severe traumatic brain injury. J Neurotrauma. 2023;40:2118–25. https://doi.org/10.1089/neu.2022.0516. · DOI
- Bogucki A, John I, Zinkiewicz Ł, Jachura M, Jaworski D, Suwała K, Chrost H, Wlodarski M, Kałużny J, Campbell D, Bakken P, Pandya S, Chrapkiewicz R, Manohar SG. Machine learning approach for ambient-light-corrected parameters and the pupil reactivity (PuRe) score in smartphone-based pupillometry. Front Neurol. 2024;15:1363190. https://doi.org/10.3389/fneur.2024.1363190. · DOI · Paper page
- Rattan Y, Girgla KK, Mahajan G, Prasher P. Interdevice agreement between a smartphone and a commercial pupillometer. Int J Appl Basic Med Res. 2024;14:23–8. https://doi.org/10.4103/ijabmr.ijabmr_396_23. · DOI
Cited by
Pupil and Pupillary Light Reflex
Özdağ, D., & Oztas, B. (2025) · Sakarya Üniversitesi Holistik Sağlık Dergisi · doi:10.54803/sauhsd.1767753 · Cited by 1
Metadata
- Authors
- Holmskär, S., Öhrn, M., Furudahl, M., Kesti, J., & Pansell, J.
- Venue
- Journal of Clinical Monitoring and Computing
- Published
- 2025-04-10
- Volume
- 39
- Issue
- 5
- Pages
- 975-986
- ISSN
- 1573-2614
- Cited by
- 11
- References
- 0
- Language
- en
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Funders
- Karolinska Institute
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Is quantitative pupillometry affected by ambient light? A prospective crossover study. https://app.cochat.ai/papers/10.1007/s10877-025-01293-z
- The paper
- Holmskär, S., Öhrn, M., Furudahl, M., Kesti, J., & Pansell, J. (2025). Is quantitative pupillometry affected by ambient light? A prospective crossover study. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-025-01293-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.