HEMT-Based 1 K Front-End Electronics for the Heat and Ionization Ge CryoCube of the Future Ricochet CE$$\nu $$NS Experiment
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The Ricochet reactor neutrino observatory is planned to be installed at the Laue Langevin Institute starting mid-2022. Its scientific goal is to perform a low-energy and high precision measurement of the coherent elastic neutrino-nucleus scattering spectrum in order to explore exotic physics scenarios. Ricochet will host two cryogenic detector arrays: the CryoCube (Ge target) and the Q-array (Zn target), operated at 10 mK. The 1 kg Ge CryoCube will consist of 27 Ge crystals instrumented with NTD-Ge thermal sensors and charge collection electrodes for a simultaneous heat and ionization readout to reject the electromagnetic backgrounds (gamma, beta, x-rays). We present the status of its front-end electronics. The first stage of amplification is made of High Electron Mobility Transistors developed by CNRS/C2N laboratory, optimized to achieve ultra-low noise performance at 1 K with a dissipation as low as 15 μ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu $$\end{document}W per channel. Our noise model predicts that 10 eV heat and 20 eVee\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$_{\mathrm{ee}}$$\end{document} R…
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“G. Baulieu etal. [30] suggests a low-power, low-noise HEMT based amplifier, but the gain achieved is significantly lower than what is required for our trap application.”
From Development and Characterization of a Cryogenic Tuned Amplifier for Penning Trap Applications (2025) · cites this paper as [30]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Observation of coherent elastic neutrino-nucleus scattering
Akimov, D., Albert, J. B., An, P., Awe, C., Barbeau, P. S., Becker, B., Belov, V., Brown, A., Bolozdynya, A., Cabrera-Palmer, B., et al. (2017) · Science · doi:10.1126/science.aao0990 · Cited by 765
Searching for low-mass dark matter particles with a massive Ge bolometer operated above ground
Armengaud, E., Augier, C., Benoît, A., Benoit, A., Bergé, L., Billard, J., Broniatowski, A., Camus, P., Cazes, A., Chapellier, M., et al. (2019) · Physical Review D · doi:10.1103/physrevd.99.082003 · Cited by 239
Self-citationBackground studies for the MINER Coherent Neutrino Scattering reactor experiment
Agnolet, G., Baker, W., Barker, D., Beck, R., Carroll, T. J., Cesar, J., Cushman, P., Dent, J. B., De Rijck, S., Dutta, B., et al. (2017) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2017.02.024 · Cited by 171
Performance of the EDELWEISS-III experiment for direct dark matter searches
Armengaud, E., Arnaud, Q., Augier, C., Benoit, A. D., Bergé, L., Bergmann, T., Billard, J., de Boissière, T., Bres, G., Broniatowski, A., et al. (2017) · Journal of Instrumentation · doi:10.1088/1748-0221/12/08/p08010 · Cited by 152
Self-citationNoise in AlGaAs/InGaAs/GaAs pseudomorphic HEMTs from 10 Hz to 18 GHz
Plana, R., Escotte, L., Llopis, O., Amine, H., Parra, T., Gayral, M., & Graffeuil, J. (1993) · IEEE Transactions on Electron Devices · doi:10.1109/16.210190 · Cited by 56
Dong, Q., Liang, Y. X., Ferry, D., Cavanna, A., Gennser, U., Couraud, L., & Jin, Y. (2014) · Applied Physics Letters · doi:10.1063/1.4887368 · Cited by 52 · cited 2×
“In previous work [10] we have shown that HEMTs developed by the CNRS/C2N laboratory [11, 12], and now commercially available at the CryoHEMT company [13], could be used as high impedance input and could meet the resolution goals with a total input (detector + cabling) capacitance of 20 pF.”
MethodSelf-citationAugier, C., Beaulieu, G., Belov, V., Bergé, L., Billard, J., Bres, G., Bret, J. L., Broniatowski, A., Calvo, M., Cazes, A., et al. (2023) · Journal of Low Temperature Physics · doi:10.1007/s10909-023-02971-5 · Cited by 32
Self-citationPhipps, A., Juillard, A., Sadoulet, B., Serfass, B., & Jin, Y. (2016) · Nuclear Instruments and Methods in Physics Research Section A : Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2019.06.022 · Cited by 20
Self-citationSalagnac, T., Billard, J., Colas, J., Chaize, D., Jésus, M. D., Dumoulin, L., Filippini, J.-B., Gascon, J., Juillard, A., Lattaud, H., et al. (2023) · Journal of Low Temperature Physics · doi:10.1007/s10909-023-02960-8 · Cited by 18
Self-citationUltra-low noise HEMTs for deep cryogenic low-frequency and high-impedance readout electronics
Jin, Y., Dong, Q., Cavanna, A., Gennser, U., Couraud, L., & Ulysse, C. (2014) · IEEE International Conference on Solid-State and Integrated Circuit Technology · doi:10.1109/icsict.2014.7021379 · Cited by 12
Self-citationJuillard, A., Billard, J., Chaize, D., Filippini, J., Misiak, D., Vagneron, L., Cavanna, A., Dong, Q., Jin, Y., Ulysse, C., et al. (2019) · Journal of Low Temperature Physics · doi:10.1007/s10909-019-02269-5
Self-citation
Research works printed but not linked: 1
- Excess Workshop, June 2021
Cited by
Development and Characterization of a Cryogenic Tuned Amplifier for Penning Trap Applications
Chaddha, N., Sikdar, A. K., Nandi, J., Vyshnav, C. H., Chatterjee, M., Das, P., & Ray, A. (2025) · Journal of Low Temperature Physics · doi:10.1007/s10909-025-03309-z
Metadata
- Authors
- Baulieu, G., Billard, J., Bres, G., Bret, J.-L., Chaize, D., Colas, J., Dong, Q., Exshaw, O., Guerin, C., Ferriol, S., Filippini, J.-B., De Jesus, M., Jin, Y., Juillard, A., Lamblin, J., Lattaud, H., Minet, J., Misiak, D., Monfardini, A., Rarbi, F., Salagnac, T., Vagneron, L., & the Ricochet Collaboration
- Affiliations
- Lyon 1 Université (FR)
- Centre National de la Recherche Scientifique (FR)
- Corresponding author
- Juillard, A.
- ORCID
- Venue
- Journal of Low Temperature Physics
- Published
- 2022-11
- Volume
- 209
- Issue
- 3-4
- Pages
- 570-580
- ISSN
- 0022-2291 (ISSN-L)
- 1573-7357
- OpenAlex
- W3215204505
- Cited by
- 0
- References
- 11
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Journal of Low Temperature Physics (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- HAL (submittedVersion)
- arXiv (Cornell University) (cc-by)
- Funders
- Agence Nationale de la Recherche (ANR-11-IDEX-0007, ANR-10-LABX-0066)
- Topics
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle Detector Development and Performance
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Neutrino Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting and THz Device Technology
- Keywords
- high electron mobility transistors, front-end electronics, coherent elastic neutrino-nucleus scattering, low-noise amplification, nuclear recoil discrimination, low-energy neutrino detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.