pH-responsive hydrogel membranes based on modified chitosan: water transport and kinetics of swelling
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
pH-responsive membranes prepared by treating chitosan (Ch) with glutaraldehyde (GA) or with GA and sulfuric acid (SA) were studied. The structure and properties of the membranes were characterized by Fourier transform infrared (FTIR) spectroscopy, wide-angle X-ray diffraction (WAXD), scanning electron microscopy (SEM), atomic force microscopy (AFM), thermogravimetric analysis (TGA), differential scanning calorimetry (DSC) and elemental analysis. The effect of the cross-linking process both on the dynamic swelling behaviour of the hydrogel membranes and on the mechanism of water transport through those membranes was investigated in buffer solutions of different pH (1.2–9.5). The mechanism of water transport through the hydrogel chitosan membranes was affected by membrane composition and pH of the swelling medium. Non-cross-linked Ch membrane showed a non-Fickian swelling behaviour in the pH range 6.5–9.5. Chitosan membrane cross-linked with GA (Ch/GA) showed less-Fickian or Fickian swelling behaviour in all buffer solutions. In the case of chitosan membrane cross-linked with GA and SA (Ch/GA/SA), at low pH (lower than the pK a of the hydrogel) the water transport was controlled more by polymer relaxation than by penetrant diffusion. The experimental data clearly suggested that the swelling process in all buffer solutions obeyed second-order kinetics. Values of an apparent swelling rate constant for Ch/GA and Ch/GA/SA membranes were of the same order of magnitude for acidic and neutral swelling media but they increased for alkaline solutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels in pharmaceutical formulations
Peppas, N. (2000) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(00)00090-4 · Cited by 4,011
Synthesis and swelling behavior of xanthan-based hydrogels
Bueno, V. B., Bentini, R., Catalani, L. H., & Petri, D. F. S. (2013) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2012.10.062 · Cited by 329
Chitin, Chitosan, Oligosaccharides and Their Derivatives: Biological Activities and Applications
(2010) · CRC Press eBooks · doi:10.1201/ebk1439816035 · Cited by 215
Cited by
Responsive hydrogel dressings for intelligent wound management
Wang, S., Wu, W., Yeo, J. C. C., Soo, X. Y. D., Thitsartarn, W., Liu, S., Tan, B. H., Suwardi, A., Li, Z., Zhu, Q., et al. (2023) · BMEMat · doi:10.1002/bmm2.12021 · Cited by 218
Yazdi, M. K., Vatanpour, V., Taghizadeh, A., Taghizadeh, M., Ganjali, M. R., Munir, M. T., Habibzadeh, S., Saeb, M. R., & Ghaedi, M. (2020) · Materials Science and Engineering: C · doi:10.1016/j.msec.2020.111023 · Cited by 209
Chitosan Based Materials in Cosmetic Applications: A Review
Kulka, K., & Sionkowska, A. (2023) · Molecules · doi:10.3390/molecules28041817 · Cited by 157
Refaat Alawady, A., Ali Alshahrani, A., Ali Aouak, T., & Mohamed Alandis, N. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.124267 · Cited by 108
“The main disadvantages of CHIT membranes include their substandard mechanical properties [20], poor acid stability, and low surface area, and porosity [5].”
BackgroundMalik, N. S., Ahmad, M., Alqahtani, M. S., Mahmood, A., Barkat, K., Khan, M. T., Tulain, U. R., & Rashid, A. (2021) · Drug Delivery · doi:10.1080/10717544.2021.1921074 · Cited by 57
Metadata
- Authors
- Ostrowska-Czubenko, J., Gierszewska, M., & Pieróg, M.
- Venue
- Journal of Polymer Research
- Published
- 2015-07-19
- Volume
- 22
- Issue
- 8
- ISSN
- 1022-9760 (ISSN-L)
- 1572-8935
- OpenAlex
- W2109245704
- Cited by
- 125
- References
- 3
- FWCI
- 1.88
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.