First-in-human intraoperative near-infrared fluorescence imaging of glioblastoma using cetuximab-IRDye800
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: Maximizing extent of surgical resection with the least morbidity remains critical for survival in glioblastoma patients, and we hypothesize that it can be improved by enhancements in intraoperative tumor detection. In a clinical study, we determined if therapeutic antibodies could be repurposed for intraoperative imaging during resection. METHODS: Fluorescently labeled cetuximab-IRDye800 was systemically administered to three patients 2 days prior to surgery. Near-infrared fluorescence imaging of tumor and histologically negative peri-tumoral tissue was performed intraoperatively and ex vivo. Fluorescence was measured as mean fluorescence intensity (MFI), and tumor-to-background ratios (TBRs) were calculated by comparing MFIs of tumor and histologically uninvolved tissue. RESULTS: The mean TBR was significantly higher in tumor tissue of contrast-enhancing (CE) tumors on preoperative imaging (4.0 ± 0.5) compared to non-CE tumors (1.2 ± 0.3; p = 0.02). The TBR was higher at a 100 mg dose than at 50 mg (4.3 vs. 3.6). The smallest detectable tumor volume in a closed-field setting was 70 mg with 50 mg of dye and 10 mg with 100 mg. On sections of paraffin embedded tissues, fluorescence positively correlated with histological evidence of tumor. Sensitivity and specificity of tumor fluorescence for viable tumor detection was calculated and fluorescence was found to be highly sensitive (73.0% for 50 mg dose, 98.2% for 100 mg dose) and specific (66.3% for 50 mg dose, 69.8% for 100 mg dose) for viable tumor tissue in CE tumors while normal peri-tumoral tissue showed minimal fluorescence. CONCLUSION: This first-in-human study demonstrates the feasibility and safety of antibody based imaging for CE glioblastomas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stummer, W., Pichlmeier, U., Meinel, T., Wiestler, O. D., Zanella, F., & Reulen, H.-J. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(06)70665-9 · Cited by 3,423 · cited 2×
“This is similar to what has been reported using other intraoperative contrast agents; patients are excluded from 5-ALA fluorescence-guided surgery if preoperative contrast-enhanced MRI shows no accumulation [7].”
BackgroundResultLacroix, M., Abi-Said, D., Fourney, D. R., Gokaslan, Z. L., Shi, W., DeMonte, F., Lang, F. F., McCutcheon, I. E., Hassenbusch, S. J., Holland, E., et al. (2001) · Journal of Neurosurgery · doi:10.3171/jns.2001.95.2.0190 · Cited by 3,091 · cited 2×
“A key variable associated with longer survival is the extent of safe surgical resection [2].”
BackgroundImage-guided cancer surgery using near-infrared fluorescence
Vahrmeijer, A. L., Hutteman, M., van der Vorst, J. R., van de Velde, C. J. H., & Frangioni, J. V. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.123 · Cited by 1,466 · cited 1×
“The use of tumor-targeted molecular imaging, rather than metabolic imaging, in the form of near-infrared (NIR) fluorescent dyes labeled to targeted agents has the potential to overcome some of the limitations of 5-ALA [8].”
BackgroundEpidemiologic and Molecular Prognostic Review of Glioblastoma
Thakkar, J. P., Dolecek, T. A., Horbinski, C., Ostrom, Q. T., Lightner, D. D., Barnholtz-Sloan, J. S., & Villano, J. L. (2014) · Cancer Epidemiology, Biomarkers & Prevention · doi:10.1158/1055-9965.epi-14-0275 · Cited by 1,390 · cited 1×
“Glioblastoma has one of the worst prognoses of any human tumor, as evidenced by a median overall survival of 15 months with almost 70% specific annual morbidity [1].”
BackgroundSenft, C., Bink, A., Franz, K., Vatter, H., Gasser, T., & Seifert, V. (2011) · The Lancet Oncology · doi:10.1016/s1470-2045(11)70196-6 · Cited by 826
Heimberger, A. B., Hlatky, R., Suki, D., Yang, D., Weinberg, J., Gilbert, M., Sawaya, R., & Aldape, K. (2005) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-1737 · Cited by 516 · cited 1×
“Of note, EGFR is known to be overexpressed in 50–70% of glioblastomas and has shown potential to provide robust tumor delineation from normal tissue due to its relatively low levels of expression in normal brain [12, 13].”
BackgroundSafety and Tumor Specificity of Cetuximab-IRDye800 for Surgical Navigation in Head and Neck Cancer
Rosenthal, E. L., Warram, J. M., de Boer, E., Chung, T. K., Korb, M. L., Brandwein-Gensler, M., Strong, T. V., Schmalbach, C. E., Morlandt, A. B., Agarwal, G., et al. (2015) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-14-3284 · Cited by 469 · cited 4×
“Moreover, we have demonstrated that a higher dose of cetuximab-IRDye800 leads to improved delineation between tumor and normal tissue, which is consistent with the aforementioned study in squamous cell carcinoma (SCC) with this agent [9], where increased doses led to higher signals in the primary tumor.”
BackgroundResultInfluentialSelf-citationGrabowski, M. M., Recinos, P. F., Nowacki, A. S., Schroeder, J. L., Angelov, L., Barnett, G. H., & Vogelbaum, M. A. (2014) · Journal of Neurosurgery · doi:10.3171/2014.7.jns132449 · Cited by 435 · cited 2×
“1 3 nature of glioblastoma precludes curative resection, recent studies have provided increasing support for the role of maximal safe resection in extending median survival [2, 3].”
BackgroundHow often are nonenhancing supratentorial gliomas malignant? A population study
Scott, J. N., Brasher, P. M. A., Sevick, R. J., Rewcastle, N. B., & Forsyth, P. A. (2002) · Neurology · doi:10.1212/wnl.59.6.947 · Cited by 366
Lamberts, L. E., Koch, M., de Jong, J. S., Adams, A. L. L., Glatz, J., Kranendonk, M. E. G., Terwisscha van Scheltinga, A. G. T., Jansen, L., de Vries, J., Lub-de Hooge, M. N., et al. (2017) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-16-0437 · Cited by 285 · cited 1×
“In addition, recent clinical studies have demonstrated sensitive and specific cancer detection in fluorescence-guided tumor resections using NIR probes conjugated to therapeutic antibodies in several cancer types [9, 10].”
Background
Cited by
Glioblastoma multiforme (GBM): An overview of current therapies and mechanisms of resistance
Wu, W., Klockow, J. L., Zhang, M., Lafortune, F., Chang, E., Jin, L., Wu, Y., & Daldrup-Link, H. E. (2021) · Pharmacological Research · doi:10.1016/j.phrs.2021.105780 · Cited by 805
Latest developments in molecular tracers for fluorescence image-guided cancer surgery
Hernot, S., van Manen, L., Debie, P., Mieog, J. S. D., & Vahrmeijer, A. L. (2019) · The Lancet Oncology · doi:10.1016/s1470-2045(19)30317-1 · Cited by 471
Fundamentals and developments in fluorescence-guided cancer surgery
Mieog, J. S. D., Achterberg, F. B., Zlitni, A., Hutteman, M., Burggraaf, J., Swijnenburg, R.-J., Gioux, S., & Vahrmeijer, A. L. (2022) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-021-00548-3 · Cited by 389
NIR-II light in clinical oncology: opportunities and challenges
Zhang, Z., Du, Y., Shi, X., Wang, K., Qu, Q., Liang, Q., Ma, X., He, K., Chi, C., Tang, J., et al. (2024) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-024-00892-0 · Cited by 341
Fluorescence image-guided tumour surgery
Wang, K., Du, Y., Zhang, Z., He, K., Cheng, Z., Yin, L., Dong, D., Li, C., Li, W., Hu, Z., et al. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00017-1 · Cited by 239
Metadata
- Authors
- Miller, S. E., Tummers, W. S., Teraphongphom, N., van den Berg, N. S., Hasan, A., Ertsey, R. D., Nagpal, S., Recht, L. D., Plowey, E. D., Vogel, H., Harsh, G. R., Grant, G. A., Li, G. H., & Rosenthal, E. L.
- Venue
- Journal of Neuro-Oncology
- Published
- 2018-04-06
- Volume
- 139
- Issue
- 1
- Pages
- 135-143
- ISSN
- 0167-594X (ISSN-L)
- 1573-7373
- OpenAlex
- W2795715780
- Cited by
- 160
- References
- 25
- FWCI
- 11.65
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.