Sustained Release of Multiple Growth Factors from Injectable Polymeric System as a Novel Therapeutic Approach Towards Angiogenesis
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: The aim was to investigate that a bio-degradable alginate and poly lactide-co-glycolide (PLG) system capable of delivering growth factors sequentially would be superior to single growth factor delivery in promoting neovascularization and improving perfusion. METHODS: Three groups of apoE null mice underwent unilateral hindlimb ischemia surgery and received ischemic limb intramuscular injections of alginate (Blank), alginate containing VEGF(165) (VEGF), or alginate containing VEGF(165) combined with PLG microspheres containing PDGF-BB (VEGF/PDGF). Vascularity in the ischemic hindlimb was assessed by morphologic and immunohistochemical end-points, while changes in blood flow were assessed by Laser Doppler Perfusion Index. Muscle VEGF and PDGF content was assessed at multiple time points. RESULTS: In the VEGF/PDGF group, local tissue VEGF and PDGF levels peaked at week 2 and 4, respectively, with detectable PDGF levels at week 6. At week 6, mean vessel mean diameter was significantly greater in the VEGF/PDGF group compared to the VEGF or Blank groups with evidence of well-formed smooth muscle-lined arterioles. CONCLUSIONS: Sequential delivery of VEGF and PDGF using an injectable, biodegradable platform resulted in stable and sustained improvements in perfusion. This sustained, control-released, injectable alginate polymer system is a promising approach for multiple growth factor delivery in clinical application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vascular-specific growth factors and blood vessel formation
Yancopoulos, G. D., Davis, S., Gale, N. W., Rudge, J. S., Wiegand, S. J., & Holash, J. (2000) · Nature · doi:10.1038/35025215 · Cited by 3,699
Cao, R., Bråkenhielm, E., Pawliuk, R., Wariaro, D., Post, M. J., Wahlberg, E., Leboulch, P., & Cao, Y. (2003) · Nature Medicine · doi:10.1038/nm848 · Cited by 721
Cited by
Alginate: Properties and biomedical applications
Lee, K. Y., & Mooney, D. J. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.06.003 · Cited by 8,095
Self-citationControlled drug release for tissue engineering
Rambhia, K. J., & Ma, P. X. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.08.049 · Cited by 275
Naderi, H., Matin, M. M., & Bahrami, A. R. (2011) · Journal of Biomaterials Applications · doi:10.1177/0885328211408946 · Cited by 274
Radke, D., Jia, W., Sharma, D., Fena, K., Wang, G., Goldman, J., & Zhao, F. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701461 · Cited by 256
Biomaterial-driven in situ cardiovascular tissue engineering—a multi-disciplinary perspective
Wissing, T. B., Bonito, V., Bouten, C. V. C., & Smits, A. I. P. M. (2017) · npj Regenerative Medicine · doi:10.1038/s41536-017-0023-2 · Cited by 232
Metadata
- Authors
- Sun, Q., Silva, E. A., Wang, A., Fritton, J. C., Mooney, D. J., Schaffler, M. B., Grossman, P. M., & Rajagopalan, S.
- Venue
- Pharmaceutical Research
- Published
- 2009-12-01
- Volume
- 27
- Issue
- 2
- Pages
- 264-271
- ISSN
- 0724-8741 (ISSN-L)
- 1573-904X
- OpenAlex
- W2134704551
- Cited by
- 127
- References
- 2
- FWCI
- 5.70
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sustained Release of Multiple Growth Factors from Injectable Polymeric System as a Novel Therapeutic Approach Towards Angiogenesis. https://app.cochat.ai/papers/10.1007/s11095-009-0014-0
- The paper
- Sun, Q., Silva, E. A., Wang, A., Fritton, J. C., Mooney, D. J., Schaffler, M. B., Grossman, P. M., & Rajagopalan, S. (2010). Sustained Release of Multiple Growth Factors from Injectable Polymeric System as a Novel Therapeutic Approach Towards Angiogenesis. Pharmaceutical Research. https://doi.org/10.1007/s11095-009-0014-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.