Bioimpedance basics and phase angle fundamentals
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Measurement of phase angle using bioimpedance analysis (BIA) has become popular as an index of so-called “cellular health”. What precisely is meant by this term is not always clear but strong relationships have been found between cellular water status (the relative amounts of extra- and intracellular water), cell membrane integrity and cellular mass. Much of the current research is empirical observation and frequently pays little regard to the underlying biophysical models that underpin the BIA technique or attempts to provide mechanistic explanations for the observations. This brief review seeks to provide a basic understanding of the electrical models frequently used to describe the passive electrical properties of tissues with particular focus on phase angle. In addition, it draws attention to some practical concerns in the measurement of phase angle and notes the additional understanding that can be gained when phase angle are obtained with bioimpedance spectroscopy (BIS) rather than single frequency BIA (SFBIA) along with the potential for simulation modelling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152 · cited 1×
“where alpha (α) has a value between 0 and 1 [17].”
BackgroundBioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200 · cited 1×
“1 3 dual-energy X-ray absorptiometry [5].”
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896 · cited 2×
“The method was originally developed to provide quantitative prediction of total body water (TBW) [2, 3] and fat-free mass (FFM) or lean body mass (LBM) based on a two-compartment model of the human body [4].”
BackgroundMethodDielectric properties of tissues and biological materials: a critical review.
Foster, K. R., & Schwan, H. P. (1989) · PubMed · Cited by 1,503
Norman, K., Stobäus, N., Pirlich, M., & Bosy-Westphal, A. (2012) · Clinical Nutrition · doi:10.1016/j.clnu.2012.05.008 · Cited by 1,049
Pethig, R., & Kell, D. B. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/8/001 · Cited by 796 · cited 1×
“In biological tissues where C is not constant, τ is distributed around a mean value [16] and Eq.”
BackgroundCorrelation of whole-body impedance with total body water volume.
Hoffer, E. C., Meador, C. K., & Simpson, D. C. (1969) · Journal of Applied Physiology · doi:10.1152/jappl.1969.27.4.531 · Cited by 525 · cited 4×
“(3) is solved by using an apparent resistivity (ρ) value derived, either directly or indirectly by regression, in separate calibration studies in which volume is measured as TBW using a reference method such as deuterium dilution (D2O dilution)or as FFM using (1)R = E I (2)Volume ∝ L A (3)Volume = L 2 R * Leigh C. War…”
MethodInfluentialBioelectric impedance phase angle and body composition
Baumgartner, R., Chumlea, W., & Roche, A. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/48.1.16 · Cited by 477 · cited 1×
“These more recent studies have shown that the phase angle of the trunk is consistently lower than that of the other body regions with whole-body phase angle being intermediate between that of the arm and leg unlike early studies that found trunk phase angle was larger than that of the limbs or whole body [36].”
ResultWhole-body impedance–what does it measure?
Foster, K., & Lukaski, H. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.388s · Cited by 429 · cited 4×
“As Foster and Lukaski observed in the early days of bioimpedance studies, impedance measurements reflect global characteristics of the body; the connection between impedance and body composition is indirect [6].”
BackgroundMethodInfluential
Cited by
Son, J. W., Han, B., Bennett, J. P., Heymsfield, S., & Lim, S. (2025) · Obesity Reviews · doi:10.1111/obr.13844 · Cited by 74
Asano, Y., Yoshida, T., Tsunoda, K., Yokoyama, K., Watanabe, Y., Yoshinaka, Y., Okura, T., Kimura, M., & Yamada, Y. (2025) · Experimental Gerontology · doi:10.1016/j.exger.2025.112862 · Cited by 19
Vázquez-Bautista, M. A., Robles-Sardin, A. E., Reséndiz-Sandoval, M., Navarro-Ibarra, M. J., Hernández López, J., & Caire-Juvera, G. (2025) · BIOtecnia · doi:10.18633/biotecnia.v27.2512
“These properties vary according to the body component distribution and proportion, mainly fat mass (FM) and total body water (TBW) (Kyle et al. , 2004; Ward and Brantlov, 2023).”
Metadata
- Authors
- Ward, L. C., & Brantlov, S.
- Venue
- Reviews in Endocrine and Metabolic Disorders
- Published
- 2023-02-07
- Volume
- 24
- Issue
- 3
- Pages
- 381-391
- ISSN
- 1389-9155 (ISSN-L)
- 1573-2606
- OpenAlex
- W4319334092
- Cited by
- 197
- References
- 29
- FWCI
- 28.53
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bioimpedance basics and phase angle fundamentals. https://app.cochat.ai/papers/10.1007/s11154-022-09780-3
- The paper
- Ward, L. C., & Brantlov, S. (2023). Bioimpedance basics and phase angle fundamentals. Reviews in Endocrine and Metabolic Disorders. https://doi.org/10.1007/s11154-022-09780-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.