CoChat

Randomised trial of compliance with flexible (C-Flex) and standard continuous positive airway pressure for severe obstructive sleep apnea

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Introduction Obstructive sleep apnea (OSA) is often treated with continuous positive airway pressure (CPAP) but the effectiveness of treatment is probably limited by poor compliance. CPAP manufacturers are thus attempting to devise more comfortable PAP devices in an effort to improve compliance. An example of such a novel device is Flexible expiratory-modulated PAP (C-Flex mode Respironics REMstar Pro, Murraysville, PA, USA). Materials and methods We aimed to compare compliance between C-Flex and standard CPAP in patients with severe OSA in a randomised controlled trial. Nineteen patients with severe OSA (mean +/- SD Apnea Hypopnea Index = 78 +/- 33/h, Epworth 14 +/- 4, PAP 8-17 cm H2O, BMI = 39 +/- 10 kg/m2) and aged 20-63 years were randomly assigned to 4 weeks of either C-Flex (setting II, n = 9) or CPAP (n = 10). Results Patients treated with C-Flex exhibited a trend toward higher compliance with their PAP devices compared to patients treated with standard CPAP (4.7 +/- 2.9 vs. 3.0 +/- 2.1 h/night, p = 0.15, effect size = 0.68). Paradoxically, improvements in subjective sleepiness (Epworth Sleepiness Scale) were greater in those who received CPAP than C-Flex (8.1 + 4.9 vs. 2.1 + 4.0 points, p = 0.014, effect size = 1.46). Improvements in objective wakefulness (Modified Maintenance of Wakefulness Test) and simple reaction times (Psychomotor Vigilance Task) were not significantly different between treatments. This randomised trial provides some evidence that C-Flex might in…

Overview

Integrity signals

Registry

Crossref · 10.1007/s11325-008-0189-3

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 17 references

Cited by

See all 38

Metadata

Authors
Marshall, N. S., Neill, A. M., & Campbell, A. J.
Affiliations
  • Woolcock Institute of Medical Research (AU)
  • University of Otago (NZ)
Corresponding author
Marshall, Nathaniel S.
Venue
Sleep and Breathing
Published
2008-05-31
Volume
12
Issue
4
Pages
393-396
ISSN
  • 1520-9512 (ISSN-L)
  • 1522-1709
OpenAlex
W2052267758
Cited by
38
References
17
Citations by year
2026: 1 · 2021: 1 · 2020: 1 · 2019: 2 · 2017: 2 · 2016: 4 · 2015: 3 · 2014: 3 · 2013: 2 · 2012: 4
FWCI
3.39
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Sleep And Breathing (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
Keywords
obstructive sleep apnea, CPAP adherence, daytime sleepiness, wakefulness, reaction time, medication adherence
MeSH terms
Adult, Equipment Design, Female, Humans, Male, Middle Aged, Patient Compliance, Single-Blind Method, Treatment Outcome, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Randomised trial of compliance with flexible (C-Flex) and standard continuous positive airway pressure for severe obstructive sleep apnea. https://app.cochat.ai/papers/10.1007/s11325-008-0189-3
The paper
Marshall, N. S., Neill, A. M., & Campbell, A. J. (2008). Randomised trial of compliance with flexible (C-Flex) and standard continuous positive airway pressure for severe obstructive sleep apnea. Sleep and Breathing. https://doi.org/10.1007/s11325-008-0189-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.