Randomised trial of compliance with flexible (C-Flex) and standard continuous positive airway pressure for severe obstructive sleep apnea
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Introduction Obstructive sleep apnea (OSA) is often treated with continuous positive airway pressure (CPAP) but the effectiveness of treatment is probably limited by poor compliance. CPAP manufacturers are thus attempting to devise more comfortable PAP devices in an effort to improve compliance. An example of such a novel device is Flexible expiratory-modulated PAP (C-Flex mode Respironics REMstar Pro, Murraysville, PA, USA). Materials and methods We aimed to compare compliance between C-Flex and standard CPAP in patients with severe OSA in a randomised controlled trial. Nineteen patients with severe OSA (mean +/- SD Apnea Hypopnea Index = 78 +/- 33/h, Epworth 14 +/- 4, PAP 8-17 cm H2O, BMI = 39 +/- 10 kg/m2) and aged 20-63 years were randomly assigned to 4 weeks of either C-Flex (setting II, n = 9) or CPAP (n = 10). Results Patients treated with C-Flex exhibited a trend toward higher compliance with their PAP devices compared to patients treated with standard CPAP (4.7 +/- 2.9 vs. 3.0 +/- 2.1 h/night, p = 0.15, effect size = 0.68). Paradoxically, improvements in subjective sleepiness (Epworth Sleepiness Scale) were greater in those who received CPAP than C-Flex (8.1 + 4.9 vs. 2.1 + 4.0 points, p = 0.014, effect size = 1.46). Improvements in objective wakefulness (Modified Maintenance of Wakefulness Test) and simple reaction times (Psychomotor Vigilance Task) were not significantly different between treatments. This randomised trial provides some evidence that C-Flex might in…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A meta-analysis of 5 RCTs 188,236-239 demonstrated no clinically significant difference in self-reported sleepiness between participants on modified pressure profile PAP compared to standard PAP (see supplemental material, Figure S86).”
Citations
Cites
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364 · cited 1×
“The secondary outcomes were improvements in daytime sleepiness (Epworth Sleepiness Scale[12] and a modified maintenance of wakefulness test[13]) and simple reaction time (Psychomotor Vigilance Task[14]).”
BackgroundThe Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults
Young, T., Palta, M., Dempsey, J., Skatrud, J., Weber, S., & Badr, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304293281704 · Cited by 10,183 · cited 1×
“Obstructive sleep apnea (OSA) is a common sleep breathing disorder[1] associated with excessive daytime sleepiness[2] and the development of hypertension.”
BackgroundProspective Study of the Association between Sleep-Disordered Breathing and Hypertension
Peppard, P. E., Young, T., Palta, M., & Skatrud, J. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005113421901 · Cited by 4,973 · cited 1×
“[3] Meta analyses have shown that continuous positive airway pressure (CPAP) is an effective treatment for the daytime manifestations of severe OSA.”
BackgroundSullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731 · cited 2×
“matically splints open the collapsible sleeping airway and is nearly 100% effective in alleviating obstructions when properly applied.[ 6 ] Sub-optimal compliance thus appears to be a major factor limiting CPAP’s effectiveness.[7] Whilst there are many factors that have been shown to affect compliance levels,[7] techn…”
BackgroundEffect Sizes for Interpreting Changes in Health Status
Kazis, L. E., Anderson, J. J., & Meenan, R. F. (1989) · Medical Care · doi:10.1097/00005650-198903001-00015 · Cited by 2,401 · cited 1×
“Effect size calculations[15] were achieved by dividing the size (or net size of the effect) by the pooled standard deviation of both groups (primary outcome only) or the standard deviation of that measurement at baseline across both groups (secondary outcomes).”
BackgroundDinges, D. F., & Powell, J. W. (1985) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03200977 · Cited by 1,744 · cited 1×
“The secondary outcomes were improvements in daytime sleepiness (Epworth Sleepiness Scale[12 ]a nd a modified maintenance of wakefulness test[13]) and simple reaction time (Psychomotor Vigilance Task[ 14 ]).”
BackgroundWeaver, T. E., Maislin, G., Dinges, D. F., Bloxham, T., George, C. F. P., Greenberg, H., Kader, G., Mahowald, M., Younger, J., & Pack, A. I. (2007) · Sleep · doi:10.1093/sleep/30.6.711 · Cited by 1,058
Continuous positive airways pressure for obstructive sleep apnoea in adults
Giles, T., Lasserson, T., Smith, B., White, J., Wright, J., & Cates, C. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001106.pub2 · Cited by 1,001 · cited 1×
“[4, 5] CPAP therapy pneuSleep Breath (2008) 12:393–396”
Katan, M., & Van De Bovenkamp, P. (1987) · The Lancet · doi:10.1016/s0140-6736(87)91641-2 · Cited by 964
Relation of Sleepiness to Respiratory Disturbance Index: The Sleep Heart Health Study
GOTTLIEB, D. J., WHITNEY, C. W., BONEKAT, W. H., IBER, C., JAMES, G. D., LEBOWITZ, M., NIETO, F. J., & ROSENBERG, C. E. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.2.9804051 · Cited by 572 · cited 1×
“Obstructive sleep apnea (OSA) is a common sleep breathing disorder[1] associated with excessive daytime sleepiness[2] and the development of hypertension.”
Background
Cited by
Trends in CPAP adherence over twenty years of data collection: A flattened curve
Rotenberg, B. W., Murariu, D., & Pang, K. P. (2016) · Journal of Otolaryngology - Head & Neck Surgery · doi:10.1186/s40463-016-0156-0 · Cited by 742
Patil, S. P., Ayappa, I. A., Caples, S. M., Kimoff, R. J., Patel, S. R., & Harrod, C. G. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7638 · Cited by 721
Weaver, T. E., & Sawyer, A. M. (2010) · PubMed · Cited by 385
Smith, I., & Lasserson, T. J. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub3 · Cited by 151
Fleetham, J., Ayas, N., Bradley, D., Fitzpatrick, M., Oliver, T. K., Morrison, D., Ryan, F., Series, F., Skomro, R., Tsai, W., et al. (2011) · Canadian Respiratory Journal · doi:10.1155/2011/506189 · Cited by 131
Rotenberg, B. W., Vicini, C., Pang, E. B., & Pang, K. P. (2016) · Journal of Otolaryngology - Head & Neck Surgery · doi:10.1186/s40463-016-0136-4 · Cited by 95
Bakker, J., Campbell, A., & Neill, A. (2010) · Sleep · doi:10.1093/sleep/33.4.523 · Cited by 55
Self-citationBakker, J. P., & Marshall, N. S. (2010) · CHEST Journal · doi:10.1378/chest.10-2379 · Cited by 61
Self-citationPredictors of continuous positive airway pressure adherence
Catcheside, P. G. (2010) · F1000 Medicine Reports · doi:10.3410/m2-70 · Cited by 49
“While the impact of new technologies on patient preference and treatment adherence remain largely to be established, there is some evidence that improved mask comfort and algorithms designed to modulate pressure to further improve patient comfort are useful in some patients [20,51,59,60].”
BackgroundKennedy, B., Lasserson, T. J., Wozniak, D. R., & Smith, I. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub4 · Cited by 47
Flexible Positive Airway Pressure Improves Treatment Adherence Compared with Auto-adjusting PAP
Chihara, Y., Tsuboi, T., Hitomi, T., Azuma, M., Murase, K., Toyama, Y., Harada, Y., Aihara, K., Tanizawa, K., Handa, T., et al. (2013) · Sleep · doi:10.5665/sleep.2378 · Cited by 42
Compliance with Positive Airway Pressure Treatment for Obstructive Sleep Apnea
Kim, J. H., Kwon, M. S., Song, H. M., Lee, B.-J., Jang, Y. J., & Chung, Y. (2009) · Clinical and Experimental Otorhinolaryngology · doi:10.3342/ceo.2009.2.2.90 · Cited by 42
“But other reports presented compliance as the duration of nightly use of the device (8), the amount of time that the device is switched on and being worn correctly so as to deliver effective therapeutic pressure (9) and percentage of days CPAP was used, mean daily use (hr) and mean daily use on days CPAP was used (10).”
MethodCampbell, A., Neill, A., & Lory, R. (2012) · Internal Medicine Journal · doi:10.1111/j.1445-5994.2010.02360.x · Cited by 35
Self-citationEnhancing Adherence to Positive Airway Pressure Therapy for Sleep Disordered Breathing
Russell, T. (2014) · Seminars in Respiratory and Critical Care Medicine · doi:10.1055/s-0034-1390070 · Cited by 27
Zhu, K., Aouf, S., Roisman, G. L., & Escourrou, P. (2016) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.5590 · Cited by 25
Control system design for a continuous positive airway pressure ventilator
Chen, Z., Hu, Z., & Dai, H. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-5 · Cited by 26
Gulati, A., Oscroft, N. S., Chadwick, R., Ali, M., & Smith, I. (2015) · Respiratory Medicine · doi:10.1016/j.rmed.2015.01.020 · Cited by 21
Assessment of the impact on compliance of a new CPAP system in obstructive sleep apnea
Wimms, A. J., Richards, G. N., & Benjafield, A. (2012) · Sleep And Breathing · doi:10.1007/s11325-012-0651-0 · Cited by 19
“Short term usage tends to predict longer term compliance, and it is common for studies investigating device changes to measure compliance after 4 weeks [9, 12].”
BackgroundNadeem, R. N., Rishi, M. A., Srinivasan, L., Copur, A. S., & Naseem, J. (2012) · Respiratory Care · doi:10.4187/respcare.01539 · Cited by 15
Continuous positive airway pressure therapy: new generations.
Garvey, J., & McNicholas, W. T. (2010) · PubMed · Cited by 19
Factors affecting compliance with positive airway pressure therapy in obstructive sleep apnea
Erçelik, M., Balbay, E. G., Gülhan, P. Y., Cangür, Ş., Arbak, P., Aytekin, F., & Elverişli, M. F. (2021) · Sleep And Breathing · doi:10.1007/s11325-021-02447-4 · Cited by 10
Fulda, S., & Schulz, H. (2010) · Progress in brain research · doi:10.1016/b978-0-444-53702-7.00005-1 · Cited by 8
“In a few studies, one PAP treatment was compared to another PAP treatment (Bakker et al., 2010; Marshall et al., 2008; Meurice et al., 1998; Senn et al., 2003) or to withdrawal of treatment (Kribbs et al.”
MethodToraldo, D. M., Nuccio, F. D., & Nicolardi, G. (2011) · Expert Review of Respiratory Medicine · doi:10.1586/ers.10.86 · Cited by 9
Sunderram, J., Ayappa, I. A., Lu, S., Wang, H., Black, K., Twumasi, A., Sanders, H., Harrison, D. J., Udasin, I. G., Chitkara, N., et al. (2021) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202009-1161oc · Cited by 6
Jerrentrup, L., Canisius, S., Wilhelm, S., Kesper, K., Ploch, T., Vogelmeier, C. F., Greulich, T., & Becker, H. F. (2016) · Respiration · doi:10.1159/000452423 · Cited by 5
Masdeu, M. J., Patel, A., Seelall, V., Rapoport, D. M., & Ayappa, I. A. (2012) · SLEEP · doi:10.5665/sleep.1636 · Cited by 5
The SomnuSeal Oral Mask Is Reasonably Tolerated by Otherwise CPAP Noncompliant Patients with OSA
Katz, N., Adir, Y., Etzioni, T., Kurtz, E., & Pillar, G. (2013) · Sleep Disorders · doi:10.1155/2013/840723 · Cited by 5
“Hindawi Publishing Corporation Sleep Disorders Volume 2013, Article ID 840723, 6 pages http://dx.doi.org/10.1155/2013/840723”
BackgroundInfluentialAdherence to and Complications of CPAP in Obstructive Sleep Apnea: Key Determinants
BaHammam, A. S., Hussain, A., & Alasmri, M. (2015) · Springer eBooks · doi:10.1007/978-3-319-21653-9_82 · Cited by 3
Positive Airway Pressure Treatment
Berry, R. B. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-0326-9.00019-1 · Cited by 2
Testing the Performance of Positive Airway Pressure Generators
Zhu, K., Francs, C. C. D., Sagniez, A., & Escourrou, P. (2017) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2017.07.002 · Cited by 3
Messineo, L., Bakker, J. P., Noah, W. H., & White, D. P. (2026) · EClinicalMedicine · doi:10.1016/j.eclinm.2026.103993 · Cited by 1
Use of nNIV in Obstructive Sleep Apnea: Modes, Flexes, and More
Weingarten, J. A. (2015) · Springer eBooks · doi:10.1007/978-1-4899-7624-6_9 · Cited by 1
“When objective measures were assessed, studies found no differences in psychomotor vigilance testing (PVT) and modified MWT results between those randomized to CPAP with PR or standard CPAP [36, 39].”
BackgroundMethodResultInfluentialAdherence to Positive Airway Pressure Therapy
Arfoosh, R., & Rowley, J. A. (2010) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2010.05.012 · Cited by 1
Dimitrova, P. (2014) · Universitätsbibliothek der FU Berlin Hochschulschriftenstelle u. Dokumentenserver · doi:10.17169/refubium-17448
Gulati, A. (2017) · University of Hertfordshire Research Archive (University of Hertfordshire) · doi:10.18745/th.17731
Berry, R. B., & Wagner, M. H. (2014) · Elsevier eBooks · doi:10.1016/b978-1-4557-7051-9.00023-1
(2009) · Current Opinion in Pulmonary Medicine · doi:10.1097/mcp.0b013e3283328a80
Metadata
- Authors
- Marshall, N. S., Neill, A. M., & Campbell, A. J.
- Affiliations
- Woolcock Institute of Medical Research (AU)
- University of Otago (NZ)
- Corresponding author
- Marshall, Nathaniel S.
- Venue
- Sleep and Breathing
- Published
- 2008-05-31
- Volume
- 12
- Issue
- 4
- Pages
- 393-396
- ISSN
- 1520-9512 (ISSN-L)
- 1522-1709
- OpenAlex
- W2052267758
- Semantic Scholar
- 8a6b3bb7563b80c6c8718e1868017fcb66ce6696
- Cited by
- 38
- References
- 17
- Citations by year
- 2026: 1 · 2021: 1 · 2020: 1 · 2019: 2 · 2017: 2 · 2016: 4 · 2015: 3 · 2014: 3 · 2013: 2 · 2012: 4
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Sleep And Breathing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Keywords
- obstructive sleep apnea, CPAP adherence, daytime sleepiness, wakefulness, reaction time, medication adherence
- MeSH terms
- Adult, Equipment Design, Female, Humans, Male, Middle Aged, Patient Compliance, Single-Blind Method, Treatment Outcome, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.