Cited by 55Obstructive Sleep Apnea ResearchSleep and related disordersRespiratory Support and Mechanisms

Randomized Controlled Trial Comparing Flexible and Continuous Positive Airway Pressure Delivery: Effects on Compliance, Objective and Subjective Sleepiness and Vigilance

Open access
Bakker, Jessie, Campbell, Angela, Neill, Alister·2010·Sleep

Abstract

STUDY OBJECTIVES: Positive airway pressure (PAP) treatment for obstructive sleep apnea (OSA) can be limited by suboptimal compliance. C-Flex technology (Philips Respironics, PA, USA) reduces pressure during expiration, aiming to improve comfort and therefore compliance. This may be of particular relevance to patients requiring high pressures. Many studies thus far have suffered from design limitations and small sample sizes. This study aimed to compare compliance with C-Flex and CPAP, as well as analyzing objective and subjective sleepiness and vigilance. DESIGN: Three-month, double-blinded, parallel-arm randomized controlled trial. SETTING: A university-based sleep laboratory. PATIENTS: 76 consecutive patients with severe OSA (mean +/- SD AHI 60.2 +/- 32.9 events/hour, ESS 13.6 +/- 4.5/24, BMI 35.6 +/- 7.8 kg/m2), without significant cardiac, respiratory, psychiatric, or sleep comorbidities. INTERVENTIONS: Patients were randomized to C-Flex (dip level 2) or CPAP. MEASUREMENTS AND RESULTS: Patients underwent titration with C-Flex/CPAP (mean pressure 11.6 cm H2O). Modified maintenance of wakefulness tests (mod-MWT), psychomotor vigilance tasks (PVT) and questionnaires were administered at baseline and after one and 3 months. Median compliance was 5.51 and 5.89 h/night in the C-Flex and CPAP groups respectively (P = 0.82). There were no significant differences between groups in terms of PVT reaction time, subjective sleepiness, sleep quality, health-related quality of life, or treatment comfort. There was no significant difference between the groups regarding the change in mod-MWT sleep latency values. CONCLUSIONS: In patients with severe OSA both CPAP and C-Flex resulted in substantial improvements in sleepiness, vigilance, and quality of life. The use of C-Flex did not result in greater compliance, and neither treatment appeared superior.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/sleep/33.4.523

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 50 references couldn’t be matched to a known paper.

Research works printed but not linked: 2

  1. [14]14. Pankow W, Lies A, Nabe B, Becker H, Ploch T, Lohmann F. Continuous positive airway pressure lowers blood pressure in hypertensive patients with obstructive sleep apnea. Somnologie 2003;7:17-22.
  2. [26]26. Wenzel M, Kerl J, Dellweg D, Barchfeld T, Wenzel G, Kohler D. Expiratory pressure reduction (C-Flex Method) versus fix CPAP in the therapy for obstructive sleep apnoea. Pneumologie 2007;61:692-5.

Cited by

Sorted by citations

Authors
Bakker, J., Campbell, A., & Neill, A.
Affiliations
  • University of Otago (NZ)
  • Health New Zealand (NZ)
Corresponding author
Bakker, Jessie
Venue
Sleep
Published
2010-04
Volume
33
Issue
4
Pages
523-529
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W1608027688
Cited by
55
References
50
Citations by year
2026: 2 · 2024: 3 · 2022: 1 · 2021: 2 · 2020: 1 · 2019: 4 · 2018: 1 · 2017: 3 · 2016: 9 · 2015: 3 · 2014: 7 · 2013: 4 · 2012: 4
FWCI
4.12
Type
journal article
Language
en
Open access
Locations
  • SLEEP (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Obstructive Sleep Apnea Research
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
Keywords
obstructive sleep apnea, continuous positive airway pressure, CPAP adherence, sleepiness, sustained attention, maintenance of wakefulness test, psychomotor vigilance task, treatment comfort, health-related quality of life
MeSH terms
Adult, Aged, Arousal, Double-Blind Method, Equipment Design, Female, Follow-Up Studies, Humans, Male, Middle Aged, Patient Compliance, Psychomotor Performance, Quality of Life, Surveys and Questionnaires, Sleep, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review