Movement toward a novel activity monitoring device
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Purpose Although polysomnography is necessary for diagnosis of most sleep disorders, it is also expensive, time-consuming, intrusive, and interferes with sleep. Field-based activity monitoring is increasingly used as an alternative measure that can be used to answer certain clinical and research questions. The purpose of this study was to evaluate the reliability and validity of a novel activity monitoring device (Fitbit) compared to both polysomnography and standard actigraphy (Actiwatch-64). Methods To test validity, simultaneous Fitbit and actigraph were worn during standard overnight polysomnography by 24 healthy adults at the West Virginia University sleep research laboratory. To test inter-Fitbit reliability, three participants also wore two of the Fitbit devices overnight at home. Results Fitbit showed high intradevice reliability = 96.5-99.1. Fitbit and actigraph differed significantly on recorded total sleep time and sleep efficiency between each other and polysomnography. Bland-Altman plots indicated that both Fitbit and actigraph overestimated sleep efficiency and total sleep time. Sensitivity of both Fitbit and actigraphy for accurately identifying sleep was high within all sleep stages and during arousals; specificity of both Fitbit and actigraph for accurately identifying wake was poor. Specificity of actigraph was higher except for wake before sleep onset; sensitivity of Fitbit was higher in all sleep stages and during arousals. Conclusions The web-based Fitbit…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While the Fitbit's coarser sampling granularity does not allow measuring HRV [83] and tends to overestimate sleep duration, it has a high intra-device reliability [60]”
From Sensing Interruptibility in the Office: A Field Study on the Use of Biometric and Computer Interaction Sensors (2018) · cites this paper as [60]
In the citing paper
“Several studies have reported similar findings for the Fitbit Flex™ device (Montgomery-Downs et al., 2012; Mantua et al., 2016; Kang et al., 2017).”
From A Critical Review of Consumer Wearables, Mobile Applications, and Equipment for Providing Biofeedback, Monitoring Stress, and Sleep in Physically Active Populations (2018) · cites this paper as Montgomery-Downs et al., 2012
Citations
Cites
(2007) · Cited by 6,530
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300 · cited 1×
“Repeated measures analysis of variance and the Bland–Altman concordance technique [10] were calculated to compare devices with PSG and with each other.”
MethodTHE FIRST NIGHT EFFECT: AN EEG STUDYOF SLEEP
Agnew, H. W., Webb, W. B., & Williams, R. L. (1966) · Psychophysiology · doi:10.1111/j.1469-8986.1966.tb02650.x · Cited by 1,147 · cited 1×
“Its disadvantages include high-cost, time-intensiveness, intrusiveness, and a “firstnight effect” where sleep is disturbed by the novel environment and instrumentation [3].”
BackgroundMorgenthaler, T., Alessi, C., Friedman, L., Owens, J., Kapur, V., Boehlecke, B., Brown, T., Chesson, A., Coleman, J., Lee-Chiong, T., et al. (2007) · Sleep · doi:10.1093/sleep/30.4.519 · Cited by 1,142
Further Validation of Actigraphy for Sleep Studies
de Souza, L., Benedito-Silva, A. A., Pires, M. L. N., Poyares, D., Tufik, S., & Calil, H. M. (2003) · Sleep · doi:10.1093/sleep/26.1.81 · Cited by 587 · cited 1×
“Actigraphy is not without its disadvantages, including that it does not differentiate between sleep states, and tends to overestimate total sleep time because it does not detect brief awakenings [5].”
BackgroundPerceived Insufficient Rest or Sleep Among Adults – United States, 2008
Nolan, B. (2010) · Yearbook of Neurology and Neurosurgery · doi:10.1016/s0513-5117(09)79157-4 · Cited by 141
Cited by
Items 201–300 of 322
Janitor workload and occupational injuries
Green, D. R., Gerberich, S. G., Kim, H. S., Ryan, A. D., McGovern, P. M., Church, T. R., Schwartz, A., & Arauz, R. F. (2019) · American Journal of Industrial Medicine · doi:10.1002/ajim.22940 · Cited by 12
Multiple Types of Childhood Maltreatment, Sleep, and Anxiety in Former Foster Youth
Lee, H., & Fusco, R. A. (2021) · Child and Adolescent Social Work Journal · doi:10.1007/s10560-021-00742-3 · Cited by 14
Park, J.-S., Kim, Y., Heo, W., & Kim, S. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19052774 · Cited by 13
“Fitbit devices demonstrate 98% sensitivity to identifying sleep episodes compared to polysomnography, with interdevice reliability >96% [27].”
BackgroundSleep Duration during Pregnancy using an Activity Tracking Device
Kominiarek, M. A., Yeh, C., Balmert, L. C., Facco, F., Grobman, W. A., & Simon, M. A. (2020) · American Journal of Perinatology Reports · doi:10.1055/s-0040-1715172 · Cited by 12
Phillips, L. J., Leary, E. V., Blankenship, J., & Zimmerman, S. I. (2017) · Journal of Aging and Health · doi:10.1177/0898264317740047 · Cited by 13
Cognitive Behavioral Therapy for Insomnia in the Digital Age
Kang, S., & Kim, Y. (2019) · Advances in experimental medicine and biology · doi:10.1007/978-981-32-9721-0_30 · Cited by 12
Prediction model development of women's daily asthma control using fitness tracker sleep disruption
Castner, J., Jungquist, C. R., Mammen, M. J., Pender, J. J., Licata, O., & Sethi, S. (2020) · Heart & Lung · doi:10.1016/j.hrtlng.2020.01.013 · Cited by 11
Domingues, D. M., Rocha, P. R., Miachon, A. C. M. V., Giampá, S. Q. D. C., Soares, F., Genta, P. R., & Lorenzi‐Filho, G. (2024) · Scientific Reports · doi:10.1038/s41598-024-75935-8 · Cited by 11
Gadangi, P., Lambert, B. S., Goble, H. M., Harris, J. D., & McCulloch, P. C. (2023) · Arthroscopy Sports Medicine and Rehabilitation · doi:10.1016/j.asmr.2023.100783 · Cited by 10
Evaluating Low-cost Activity Trackers for Use in Large-scale Data Gathering of Forestry Workers
Bowen, J., Hinze, A., Cunningham, S. J., & Parker, R. (2015) · Australian Conference on Computer-Human Interaction (OzCHI) · doi:10.1145/2838739.2838741 · Cited by 13
The Effect of White Noise on Sleep in Hospitalized Patients: A Randomized Controlled Trial
Cho, M.-E., & Hwang, S.-K. (2021) · Korean Journal of Adult Nursing · doi:10.7475/kjan.2021.33.1.44 · Cited by 11
Towards Benchmarked Sleep Detection with Inertial Wrist-worn Sensing Units
Borazio, M., Berlin, E., Scholl, P., & Laerhoven, K. V. (2014) · Cited by 14
Fitness Tracker to Assess Sleep: Beyond the Market
Poyares, D. R., Hirotsu, C., & Tufik, S. B. (2015) · SLEEP · doi:10.5665/sleep.4966 · Cited by 10
A Longitudinal Pilot Study of Stress and Sleep in First-Year Osteopathic Medical Students
Pattanaik, S., Fastring, D. R., & Bateman, R. C. (2023) · Journal of Medical Education and Curricular Development · doi:10.1177/23821205231179532 · Cited by 9
Diagnosing and treating hypersomnolence in depression
Moderie, C., & Boivin, D. B. (2024) · Sleep Medicine · doi:10.1016/j.sleep.2024.10.008 · Cited by 10
Mechanical Observation Research in Social Marketing and Beyond
Bogomolova, S. (2016) · Springer eBooks · doi:10.1007/978-981-10-1829-9_8 · Cited by 12
Fucito, L. M., Ash, G. I., DeMartini, K. S., Pittman, B. P., Barnett, N. P., Li, C. R., Redeker, N. S., & O’Malley, S. S. (2021) · JMIR Research Protocols · doi:10.2196/26557 · Cited by 9
“Validation studies provide evidence of its reliability and validity relative to well-validated ambulatory and laboratory sleep assessment methods (ie, polysomnography) [86-88].”
Hirshkowitz, M. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-24288-2.00160-4 · Cited by 11
Sandoval, R., & Gilkerson, R. (2015) · Journal of the International Association of Providers of AIDS Care (JIAPAC) · doi:10.1177/2325957415601502 · Cited by 9
Zhang, S., Schaub, F., Feng, Y., & Sadeh, N. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-15742-5_71 · Cited by 11
Lanthier, M., Foti, M.-C., Fonseca, K., Higginson, C., Oksit, D., Smith, D., Lina, J., Tavakoli, P., Fogel, S. M., Ray, L., et al. (2025) · SLEEP Advances · doi:10.1093/sleepadvances/zpaf089 · Cited by 9
“The magnitude of these biases was within previously proposed margins for satisfactory differences [9–11].”
The Path Model based on Senescent Sleep Model for Sleep in Community-dwelling Older Adults
Kim, A., & Kim, O. (2015) · Korean Journal of Adult Nursing · doi:10.7475/kjan.2015.27.2.211 · Cited by 8
Cox, C., Yates, J., O’Brien, F., Pajón, L., Farrell, A. L., Ward, M., McCabe, P. G., James, A., & McNamara-Catalano, I. (2024) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph21020186 · Cited by 10
Actigraphy for estimation of the characteristics of sleep and sleep-wake rhythm
Викторович, Б. М., Коростовцева, Л. С., Медведева, Е. А., & Sviryaev, Y. V. (2019) · Russian Journal of Preventive Medicine · doi:10.17116/profmed20192202195 · Cited by 9
DeepSleep: a ballistocardiographic deep learning approach for classifying sleep stages
Rao, S., Ali, A. E., & Cesar, P. S. (2019) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/3341162.3343758 · Cited by 8
“This study is based on four datasets (distribution shown in Table 1): Dozee ’s BCG dataset, Dozee ’s ECG data, the MIT-BIH Polysomnographic dataset [7] and the PPG -based Fitbit data [10] provided by Fitabase 2 .”
Heart Rate Monitoring with Smart Wearables using Edge Computing
Dewanto, S., Alexandra, M., & Surantha, N. (2020) · International Journal of Advanced Computer Science and Applications · doi:10.14569/ijacsa.2020.0110317 · Cited by 9
“(2011) [16] created a study to compare Fitbit devices in terms of sleep efficiency calculations along with PSG and actigraphy, using each built-in sleep calculation algorithms.”
MethodEvaluation of an Activity Tracker to Detect Seizures Using Machine Learning
Mittlesteadt, J., Bambach, S., Dawes, A., Wentzel, E., Debs, A., Sezgın, E., Digby, D., Huang, Y., Ganger, A., Bhatnagar, S., et al. (2020) · Journal of Child Neurology · doi:10.1177/0883073820937515 · Cited by 8
“11,21 Limitations in our study include our sample size.”
BackgroundInvestigating the effect of daily sleep on memory capacity in college students
Phan, D., Chan, C., Pan, R.-H., Yang, N.-P., Hsu, H.-C., Ting, H.-W., Lai, K.-H. R., & Lin, K.-B. (2018) · Technology and Health Care · doi:10.3233/thc-181350 · Cited by 9
“These devices were also compared to both polysomnography and standard actigraphy (Actiwatch-64) with results showing that both devices consistently misidentify wake as sleep and thus overestimate both sleep time and quality [16].”
The Subjectivities of Wearable Sleep-Trackers - A Discourse Analysis
Nagele, A. N., Hough, J., & Dinnen, Z. (2022) · CHI Conference Extended Abstracts on Human Factors in Computing Systems (CHI EA) · doi:10.1145/3491101.3519677 · Cited by 10
“And the third area is medical sleep research [7, 8, 47, 64] including the study of chronobiology [18, 33], clinical sleep medicine [6, 55, 62] and medical computing [4, 32, 51].”
BackgroundNon-Contact Estimation of Sleep Staging
Zaffaroni, A., Doheny, E. P., Gahan, L., Ivanov, Y., Kilroy, H., O’Mahony, N., & O’Rourke, D. (2017) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-5122-7_20 · Cited by 11
Low Power Remote Neonatal Temperature Monitoring Device
Rao, H., Saxena, D., Kumar, S., Sagar, G. V., Amrutur, B. S., Mony, P. K., Thankachan, P., Shankar, K., Rao, S. P., & Bhat, S. (2014) · International Conference on Biomedical Electronics and Devices · doi:10.5220/0004798300280038 · Cited by 8
Martyn-Nemeth, P. A., Duffecy, J. L., Quinn, L., Reutrakul, S., Steffen, A. D., Burke, L., Withington, M. H. C., Irsheed, G. A., Perez, R., Park, M., et al. (2022) · Trials · doi:10.1186/s13063-022-06565-6 · Cited by 8
“Data support that consumer sleep trackers provide an estimation of sleep but are less precise than validated actigraphy devices [60, 61].”
BackgroundPark, J.-S., Murlasits, Z., & Kim, S. (2023) · Healthcare · doi:10.3390/healthcare11081201 · Cited by 10
“Fitbit devices are known to have a high accuracy rate of 98% when identifying sleep stages compared to polysomnography and have an inter-device reliability greater than 96% [24].”
BackgroundChoosing Instruments for Research: an Evaluation of Two Activity Monitors in Healthy Women
Kip, C. V. K. E. (2013) · Journal of Novel Physiotherapies · doi:10.4172/2165-7025.1000171 · Cited by 9
Exploring Path Models of Disablement in Residential Care and Assisted Living Residents
Phillips, L. J., Petroski, G. F., Conn, V. S., Brown, M., Leary, E. V., Teri, L. L., & Zimmerman, S. I. (2016) · Journal of Applied Gerontology · doi:10.1177/0733464816672048 · Cited by 9
Poonja, Z., O'Brien, P., Cross, E., Bryce, R. D. T., Dance, E., Jaggi, P., Krentz, J. R., & Thoma, B. (2018) · Cureus · doi:10.7759/cureus.2973 · Cited by 9
Hypersomnia and excessive daytime sleepiness in ischemic stroke
Ternovykh, I. К., Alekseeva, T. M., Коростовцева, Л. С., Sviryaev, Y. V., & Gavrilov, Y. V. (2021) · Arterial’naya Gipertenziya (Arterial Hypertension) · doi:10.18705/1607-419x-2021-27-5-488-498 · Cited by 6
Cárthaigh, S. M., Perry, J. L., & Griffin, C. P. (2022) · Behaviour and Information Technology · doi:10.1080/0144929x.2022.2136533 · Cited by 6
Youngmoon, K., & Oh, S. (2017) · 한국체육학회지 · doi:10.23949/kjpe.2017.03.56.2.45 · Cited by 6
Improved Mental Acuity Forecasting with an Individualized Quantitative Sleep Model
Winslow, B. D., Nguyen, N., & Venta, K. E. (2017) · Frontiers in Neurology · doi:10.3389/fneur.2017.00160 · Cited by 7
“A handful of previous studies compared Fitbit devices to other actigraphy sensors and polysomnography in general, and indicated that Fitbit sleep metrics are similar to other actigraphy devices, which, due to the prediction of sleep based on movement rather than gross neural activity, underperform compared to EEG (39–…”
BackgroundDecision tree based sleep stage estimation from nocturnal audio signals
Deng, B., Xue, B., Hong, H., Fu, C., Zhu, X., & Wang, Z. (2017) · IEEE International Conference on Digital Signal Processing (DSP) · doi:10.1109/icdsp.2017.8096119 · Cited by 6
“The first category is based on actigraphy [4]–[6], which utilizes certain physical activities such as body movement to predict sleep/wake.”
BackgroundSurfing the Third Wave of Computing: Consumer Contracting With eObjects in AustraliaPreprint
Manwaring, K. (2019) · SSRN Electronic Journal · doi:10.2139/ssrn.3890503 · Cited by 9
Obasa, A. J., Akinradewo, O. F., & Olanipekun, A. O. (2022) · International Journal of Construction Management · doi:10.1080/15623599.2022.2135943 · Cited by 5
How Much Energy Needs for Running Energy Harvesting Powered Wireless Sensor Node?
Entezami, F., Zhu, M., & Politis, C. (2016) · Energy Harvesting and Systems · doi:10.1515/ehs-2015-0017 · Cited by 5
“Examples include health and wellness monitoring devices like FitBit (Montgomery-Downs, Insana, and Bond 2012), WiThings (ASMAR 2011), Nike + (Kane et al. 2010) or mobile accessories such as Pebble Watch.”
BackgroundSigrist, S., Abel, M. G., Best, S. A., & Bollinger, L. M. (2024) · European Journal of Applied Physiology · doi:10.1007/s00421-024-05535-x · Cited by 6
Lowens, B. M. (2018) · doi:10.1145/3212711.3212714 · Cited by 5
“Wearable devices provide innovative methods for monitoring and potentially enhancing users’ health and well-being [ 4, 11, 17].”
MethodJumabhoy, R., Maskevich, S., Dap, P., Anderson, C., Stout, J. C., & Drummond, S. P. A. (2019) · PsyArXiv (OSF Preprints) · doi:10.31234/osf.io/mx2ae · Cited by 5
Measuring sleep in the bedroom environment
Cook, J. D., Castelan, A. C., & Cheng, P. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822963-7.00365-0 · Cited by 5
Pascoe, M., Wollet, A. R., Minyety, J. D. L. C., Vera, E. M., Miller, H., Celiku, O., Leeper, H. E., Fernandez, K., Reyes, J., Young, D., et al. (2024) · Neuro-Oncology Practice · doi:10.1093/nop/npae048 · Cited by 4
Evaluation of the Garmin Vivofit 4 for assessing sleep in youth experiencing sleep disturbances
Hibbing, P. R., Pilla, M., Birmingham, L., Byrd, A., Ndagijimana, T., Sadeghi, S., Seigfreid, N., Farr, D., Al-Shawwa, B. A., Ingram, D. G., et al. (2024) · Digital Health · doi:10.1177/20552076241277150 · Cited by 6
“…disorders) or the small sample size, the latter of which was also acknowledged as a limitation in the study by Meltzer et al. 17 Consistent with broader research on other monitors across populations, 14,16 – 20 our fi ndings showed dramatic underestimation of WASO when using the Vivo fi t 4.”
MethodLi, Z., Gerami-Manesch, J. C., Hoehnel, L. M., Warr, J., Haehner, A., & Hummel, T. R. (2025) · Scientific Reports · doi:10.1038/s41598-025-18075-x · Cited by 4
“Fitbit Charge 2 (Fitbit Inc., San Francisco, CA, USA) is a wrist wearable sleep monitoring device, which could measure the total sleep time, waking time, time in bed, time for light sleep, deep sleep, and rapid eye movement (REM) sleep 16 .”
Design of a Wearable Remote Neonatal Health Monitoring Device
Rao, H., Saxena, D., Kumar, S., Sagar, G. V., Amrutur, B. S., Mony, P. K., Thankachan, P., Shankar, K., Rao, S. P., & Bhat, S. (2015) · Communications in computer and information science · doi:10.1007/978-3-319-26129-4_3 · Cited by 5
Accuracy and Metrological Characteristics of Wearable Devices: A Systematic Review
Cosoli, G., & Scalise, L. (2019) · Lecture notes in electrical engineering · doi:10.1007/978-3-030-04324-7_47 · Cited by 4
SleepQual and B.Health: Smartwatch and Smartphone based Behavioral Datasets of Youth
Arora, A., Chakraborty, P., & Bhatia, M. P. S. (2022) · International Conference on Cloud Computing, Data Science & Engineering (Confluence) · doi:10.1109/confluence52989.2022.9734122 · Cited by 5
Montgomery‐Downs, H. E., & Tikotzky, L. (2021) · Springer eBooks · doi:10.1007/978-3-030-65574-7_20 · Cited by 3
Self-citationRidoy, M. Z. H., Tao, Q., Ghosh, S., Shishir, M. A., & Hu, J. (2025) · Journal of Materials Science Materials in Electronics · doi:10.1007/s10854-025-14228-w · Cited by 3
“Piezoresistive, The development of continuous and scalable sensing textiles is hampered by TENG’s complex and uniform structure [16–18].”
Sleep in Hospitalized Patients
Knauert, M. P., & Pisani, M. A. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-813014-8.00019-6 · Cited by 5
Genes for Good: Engaging the Public in Genetics Research via Social Media
Brieger, K., Zajac, G. J. M., Pandit, A., Foerster, J. R., Li, K. W., Annis, A. C., Schmidt, E. M., Clark, C. P., McMorrow, K., Zhou, W., et al. (2019) · The American Journal of Human Genetics · doi:10.1016/j.ajhg.2019.07.009 · Cited by 5
Investigating Tools and Methods for Data Capture of Forestry Workers
Griffiths, C. (2016) · Research Commons (University of Waikato) · Cited by 3
Use of technology for real-world sleep and circadian research
Chinoy, E. D., & Markwald, R. R. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822963-7.00200-0 · Cited by 3
Baarsen, A. M., van den Broek, N., Hilgenkamp, T. I. M., Festen, D. A. M., Elbers, R. G., & Huisman, S. A. (2025) · Journal of Sleep Research · doi:10.1111/jsr.70148 · Cited by 2
Savietto, S. F., Guillot, A., Harris, M., Pathmanathan, J. S., Chan, A. M., Westover, M. B., Hill, D., Bertaina‐Anglade, V., Viardot, G., Arnal, P. J., et al. (2026) · SLEEP · doi:10.1093/sleep/zsag069 · Cited by 2
“Therefore, relying on actigraphy may result in overestimation of total sleep time (TST) and underestimation of wake after sleep onset (WASO) time [ 16, 17].”
Utility of Activity Monitors and Thermometry in Assessing Sleep Stages and Sleep Quality
Swalve, N. L., Harfmann, B. D., Mitrzyk, J., & Montoye, A. H. K. (2018) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0012 · Cited by 4
Liang, Z., & Martell, M. A. C. (2018) · EAI Endorsed Transactions on Pervasive Health and Technology · doi:10.4108/eai.24-7-2018.159404 · Cited by 2
Sleep Tracker and Smartphone: Strengths and Limits to Estimate Sleep and Sleep-Disordered Breathing
Romano, S., & Insalaco, G. (2020) · Springer eBooks · doi:10.1007/978-3-030-42998-0_23 · Cited by 2
Wearable Technology Adaptation to Aviation Cabin Crew’s Fatigue Assessments
Çevik, İ., & Dahanayake, A. (2021) · Lecture notes in networks and systems · doi:10.1007/978-3-030-68476-1_23 · Cited by 4
Assessment and Management of Insomnia
Huntley, E. D., & Arnedt, J. T. (2015) · Springer eBooks · doi:10.1007/978-3-319-18054-0_10 · Cited by 2
Investigating the use of Activity Trackers to Observe High-Risk Work Environments
Bowen, J., Hinze, A., Cunningham, S. J., & Parker, R. (2015) · Research Commons (University of Waikato) · Cited by 3
Sathyanarayana, A. (2017) · University of Minnesota Digital Conservancy (University of Minnesota) · Cited by 4
Essais sur l'adoption des technologies de quantification de soi : une approche critique
Moya, J. D. (2019) · theses.fr (ABES) · doi:10.70675/71fa5e23zbc1bz4e98zb8baz67f821674d90 · Cited by 4
“Ils citent les recherches de Montgomery-Downs et al. (2012) qui ont montré la faible capacité d'un tracker Fitbit à détecter la phase de sommeil.”
BackgroundData acquisition and visual analytic tool-set for paediatric sleep data
Vincent, A., Gupta, A., Li, R., Shaw, C., & Akhyani, S. (2019) · International Conference on Pervasive Computing Technologies for Healthcare · doi:10.1145/3329189.3329228 · Cited by 2
“Montgomery-Downs et al. showed that Fitbit and actigraph based sleep monitors had limited accuracy [34].”
BackgroundHirsch, S., Peach, H. D., Moore-Harrison, T. L., Zendels, P. M., Ruggiero, A. R., & Gaultney, J. F. (2024) · Journal of Social Behavioral and Health Sciences · doi:10.5590/jsbhs.2024.18.1.02 · Cited by 1
“Montgomery-Downs et al. (2012) suggest that it is an affordable sleep measure for use on a normative population in obtaining accurate objective sleep measures.”
BackgroundWearable Technologies in Postoperative Nursing Care: Innovative Approaches in the Digital Health Age
ÇOBAN, N. (2025) · Fenerbahçe Üniversitesi Sağlık Bilimleri Dergisi · doi:10.56061/fbujohs.1794299 · Cited by 1
Pillion, M., Kim, P. R., Larsson, M., Jorge, E., Orwa, J., & Gradisar, M. (2026) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2026.102357 · Cited by 1
Work conflict : meaning, measurement, and management
LeBlanc, D. E. (2018) · Saint Mary's University Institutional Repository (Saint Mary's University) · Cited by 1
McCall, C., & Watson, N. F. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815373-4.00010-1 · Cited by 1
Activity monitor reliability and validity in community-dwelling older adults
Maganja, S. A. (2018) · Summit (Simon Fraser University) · Cited by 1
Evaluation and Management of a Sleepy Child
Morse, A. M., & Kothare, S. V. (2019) · Springer eBooks · doi:10.1007/978-3-030-14738-9_8 · Cited by 1
Schroeder, J. A., & Liston, K. M. (2023) · Journal of American College Health · doi:10.1080/07448481.2023.2235016 · Cited by 1
“27,28 PSG is also typically not suitable for recording sleep-wake patterns over multiple nights.”
Nobue, A., Sano, K., & Ishikawa, M. (2024) · Sensors · doi:10.3390/s24216820 · Cited by 1
“While wristband-type devices may be less accurate in measuring sleep quality compared to traditional polysomnography (PSG) [33,34], recent studies have shown good agreement between Fitbit devices and PSG for various sleep parameters [15–17].”
ResultKhawaja, I. S., Westermeyer, J. J., & Hurwitz, T. D. (2018) · Springer eBooks · doi:10.1007/978-1-4939-7148-0_17 · Cited by 1
A Two-Stage HMM Model for Sleep/Wake Identification via Commercial Wearable Device
Liu, J., Zhao, Y., Lai, B., & Tsui, K. (2019) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2019.8914658 · Cited by 1
“While it’s reported that Fitbit’s scoring agreed mostly with PSG but also underestimated wake duration during nocturnal sleep time in [13], we inferred that our method could also possibly overestimate sleep and underestimate wake at night.”
BackgroundAn Investigation into the Usefulness of the Smart Watch Interface for University Students
Johnson, K. M. (2014) · Cited by 1
Sleep Staging by Modeling Sleep Stage Transitions using Deep CRF.Preprint
Aggarwal, K., Khadanga, S., Joty, S., Kazaglis, L., & Srivastava, J. (2018) · arXiv (Cornell University) · Cited by 1
Legal, social and human rights challenges of the Internet of Things in AustraliaPreprint
Manwaring, K., & Hall, C. (2019) · SSRN Electronic Journal · doi:10.2139/ssrn.3464277 · Cited by 3
The potential of personal devices in large-scale sleep studies
Roomkham, S. (2020) · Queensland University of Technology · doi:10.5204/thesis.eprints.203907 · Cited by 2
Zajac, G. J. M. (2020) · Deep Blue (University of Michigan) · Cited by 1
Sleep, Physical Activity, and Cardiometabolic Health in Overweight/Obese Adolescents
Romashkin, A. (2014) · MacSphere (McMaster University) · doi:10.71548/8981 · Cited by 1
„Self-Tracking” in der Schlafmedizin
Stippig, A. (2014) · Schlaf · doi:10.1055/s-0038-1626092
Merry, K. J. (2017) · Summit (Simon Fraser University) · Cited by 2
Effects of sleep loss and sleep recovery on mood and mood regulation
Kim, Y. Y. (2018) · Murdoch University Research Portal
Dual Effects Model of Social Control: Extending the Model to 24-Hour Health Behavior
Mead, M. P. (2017) · NDSU Repository (North Dakota State University)
Janitor workload and occupational injuries
Green, D. R., Gerberich, S. G., Kim, H. S., Ryan, A. D., McGovern, P. M., Church, T. R., Schwartz, A., & Arauz, R. F. (2019) · American Journal of Industrial Medicine · doi:10.1002/ajim.23059
Nehrkorn-Bailey, A. M. (2019) · The Research Repository @ WVU (West Virginia University) · doi:10.33915/etd.3896
Health And Injury Study Of Janitorial Service Employees
Green, D. (2018) · University of Minnesota Digital Conservancy (University of Minnesota)
Metadata
- Authors
- Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A.
- Affiliations
- West Virginia University (US)
- Venue
- Sleep and Breathing
- Published
- 2011-10-06
- Volume
- 16
- Issue
- 3
- Pages
- 913-917
- ISSN
- 1520-9512 (ISSN-L)
- 1522-1709
- OpenAlex
- W2112783455
- Cited by
- 301
- References
- 6
- Citations by year
- 2026: 3 · 2025: 9 · 2024: 16 · 2023: 10 · 2022: 25 · 2021: 17 · 2020: 29 · 2019: 51 · 2018: 29 · 2017: 33 · 2016: 26 · 2015: 28 · 2014: 16 · 2013: 4 · 2012: 5
- FWCI
- 10.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Sleep And Breathing (publishedVersion)
- PubMed (publishedVersion)
- Funders
- West Virginia University
- Topics
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Circadian rhythm and melatonin
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Keywords
- Fitbit, activity monitoring, actigraphy, polysomnography, sleep efficiency, total sleep time, device reliability, device validity, sleep disorders, wearable devices
- MeSH terms
- Adult, Arousal, Equipment Design, Female, Humans, Male, Signal Processing, Computer-Assisted, Sleep Wake Disorders, Sleep Stages, Wakefulness, Reproducibility of Results, Polysomnography, Monitoring, Ambulatory, Young Adult, Actigraphy, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.