Movement toward a novel activity monitoring device
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Purpose Although polysomnography is necessary for diagnosis of most sleep disorders, it is also expensive, time-consuming, intrusive, and interferes with sleep. Field-based activity monitoring is increasingly used as an alternative measure that can be used to answer certain clinical and research questions. The purpose of this study was to evaluate the reliability and validity of a novel activity monitoring device (Fitbit) compared to both polysomnography and standard actigraphy (Actiwatch-64). Methods To test validity, simultaneous Fitbit and actigraph were worn during standard overnight polysomnography by 24 healthy adults at the West Virginia University sleep research laboratory. To test inter-Fitbit reliability, three participants also wore two of the Fitbit devices overnight at home. Results Fitbit showed high intradevice reliability = 96.5-99.1. Fitbit and actigraph differed significantly on recorded total sleep time and sleep efficiency between each other and polysomnography. Bland-Altman plots indicated that both Fitbit and actigraph overestimated sleep efficiency and total sleep time. Sensitivity of both Fitbit and actigraphy for accurately identifying sleep was high within all sleep stages and during arousals; specificity of both Fitbit and actigraph for accurately identifying wake was poor. Specificity of actigraph was higher except for wake before sleep onset; sensitivity of Fitbit was higher in all sleep stages and during arousals. Conclusions The web-based Fitbit…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While the Fitbit's coarser sampling granularity does not allow measuring HRV [83] and tends to overestimate sleep duration, it has a high intra-device reliability [60]”
From Sensing Interruptibility in the Office: A Field Study on the Use of Biometric and Computer Interaction Sensors (2018) · cites this paper as [60]
In the citing paper
“Several studies have reported similar findings for the Fitbit Flex™ device (Montgomery-Downs et al., 2012; Mantua et al., 2016; Kang et al., 2017).”
From A Critical Review of Consumer Wearables, Mobile Applications, and Equipment for Providing Biofeedback, Monitoring Stress, and Sleep in Physically Active Populations (2018) · cites this paper as Montgomery-Downs et al., 2012
Citations
Cites
(2007) · Cited by 6,530
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300 · cited 1×
“Repeated measures analysis of variance and the Bland–Altman concordance technique [10] were calculated to compare devices with PSG and with each other.”
MethodTHE FIRST NIGHT EFFECT: AN EEG STUDYOF SLEEP
Agnew, H. W., Webb, W. B., & Williams, R. L. (1966) · Psychophysiology · doi:10.1111/j.1469-8986.1966.tb02650.x · Cited by 1,147 · cited 1×
“Its disadvantages include high-cost, time-intensiveness, intrusiveness, and a “firstnight effect” where sleep is disturbed by the novel environment and instrumentation [3].”
BackgroundMorgenthaler, T., Alessi, C., Friedman, L., Owens, J., Kapur, V., Boehlecke, B., Brown, T., Chesson, A., Coleman, J., Lee-Chiong, T., et al. (2007) · Sleep · doi:10.1093/sleep/30.4.519 · Cited by 1,142
Further Validation of Actigraphy for Sleep Studies
de Souza, L., Benedito-Silva, A. A., Pires, M. L. N., Poyares, D., Tufik, S., & Calil, H. M. (2003) · Sleep · doi:10.1093/sleep/26.1.81 · Cited by 587 · cited 1×
“Actigraphy is not without its disadvantages, including that it does not differentiate between sleep states, and tends to overestimate total sleep time because it does not detect brief awakenings [5].”
BackgroundPerceived Insufficient Rest or Sleep Among Adults – United States, 2008
Nolan, B. (2010) · Yearbook of Neurology and Neurosurgery · doi:10.1016/s0513-5117(09)79157-4 · Cited by 141
Cited by
Systematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232
“For studies using accelerometry as the criterion, correlation with tracker steps was also generally high (if reported, the mean correlations were > =0.80) for the Classic [29], Ultra [29, 34], Zip [44], One [33], and UP [33] trackers.”
BackgroundMethodInfluentialAccuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616
“A total of 3 studies examined sleep in controlled settings (12 accuracy comparisons), comparing a Fitbit worn on the wrist against reference-standard polysomnography over 1 night of sleeping in a laboratory (Multimedia Appendix 3) [82-84].”
BackgroundWearable Sleep Technology in Clinical and Research Settings
DE ZAMBOTTI, M., CELLINI, N., GOLDSTONE, A., COLRAIN, I. M., & BAKER, F. C. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001947 · Cited by 564
The SBSM Guide to Actigraphy Monitoring: Clinical and Research Applications
Ancoli-Israel, S., Martin, J. L., Blackwell, T., Buenaver, L., Liu, L., Meltzer, L. J., Sadeh, A., Spira, A. P., & Taylor, D. J. (2015) · Behavioral Sleep Medicine · doi:10.1080/15402002.2015.1046356 · Cited by 559
“In fact, the few available studies suggest they are not sufficiently accurate in either clinical or research settings, and thus their use cannot currently be recommended.(10;11) The number and types of features available on actigraphy devices vary; and their relative importance and desirability for the intended purpos…”
BackgroundSleep in adolescence: Physiology, cognition and mental health
Tarokh, L., Saletin, J. M., & Carskadon, M. A. (2016) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2016.08.008 · Cited by 552
Peake, J. M., Kerr, G., & Sullivan, J. P. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00743 · Cited by 523
Sleep, Cognition, and Normal Aging: Integrating a Half Century of Multidisciplinary Research
Scullin, M. K., & Bliwise, D. L. (2015) · Perspectives on Psychological Science · doi:10.1177/1745691614556680 · Cited by 494
Ferguson, T., Rowlands, A. V., Olds, T., & Maher, C. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0201-9 · Cited by 468
Smart wearable body sensors for patient self-assessment and monitoring
Appelboom, G., Camacho, E., Abraham, M. E., Bruce, S. S., Dumont, E. L., Zacharia, B. E., D’Amico, R., Slomian, J., Reginster, J. Y., Bruyère, O., et al. (2014) · Archives of Public Health · doi:10.1186/2049-3258-72-28 · Cited by 448
“These sensors can detect many different variables such as speed, distance, steps taken, floors climbed and calories burned [16].”
Accuracy of Wristband Fitbit Models in Assessing Sleep: Systematic Review and Meta-Analysis
Haghayegh, S., Khoshnevis, S., Smolensky, M. H., Diller, K. R., & Castriotta, R. J. (2019) · Journal of Medical Internet Research · doi:10.2196/16273 · Cited by 446
“A total of 3 investigations [32,39,40] addressed this matter and they all reported acceptable consistency.”
InfluentialPerformance of seven consumer sleep-tracking devices compared with polysomnography
Chinoy, E. D., Cuellar, J. A., Huwa, K. E., Jameson, J. T., Watson, C. H., Bessman, S. C., Hirsch, D. A., Cooper, A. D., Drummond, S. P. A., & Markwald, R. R. (2021) · Sleep · doi:10.1093/sleep/zsaa291 · Cited by 433
A validation study of Fitbit Charge 2™ compared with polysomnography in adults
de Zambotti, M., Goldstone, A., Claudatos, S., Colrain, I. M., & Baker, F. C. (2018) · Chronobiology International · doi:10.1080/07420528.2017.1413578 · Cited by 413
“…studies assessing the accuracy of older Fitbit models, which relied on only motion to determine sleep/wake states [Fitbit “original”, specificity of 0.20 (Montgomery-Downs et al. 2012); Fitbit Flex, specificity of 0.35 (Cook et al. 2017) and 0.36 (Kang et al. 2017); Fitbit Ultra, specificity of…”
BackgroundInfluentialArnal, P. J., Thorey, V., Debellemaniere, E., Ballard, M. E., Bou Hernandez, A., Guillot, A., Jourde, H., Harris, M., Guillard, M., Van Beers, P., et al. (2020) · SLEEP · doi:10.1093/sleep/zsaa097 · Cited by 394
A survey on sleep assessment methods
Ibáñez, V., Silva, J., & Cauli, O. (2018) · PeerJ · doi:10.7717/peerj.4849 · Cited by 316
Mantua, J., Gravel, N., & Spencer, R. (2016) · Sensors · doi:10.3390/s16050646 · Cited by 314
“In the absence of this, the Fitbit and Withings obtained TST measures that did not differ significantly from that of PSG, contrary to others’ findings ([16–18]).”
ResultXie, J., Wen, D., Liang, L., Jia, Y., Gao, L., & Lei, J. (2018) · JMIR mHealth and uHealth · doi:10.2196/mhealth.9754 · Cited by 310
“For the measurement of sleep duration, Montgomery et al [38] found that neither the Fitbit nor the Actigraph was able to accurately identify whether a subject was asleep and often overestimated sleep duration and quality.”
MethodTwenty-four Hours of Sleep, Sedentary Behavior, and Physical Activity with Nine Wearable Devices
ROSENBERGER, M. E., BUMAN, M. P., HASKELL, W. L., MCCONNELL, M. V., & CARSTENSEN, L. L. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000778 · Cited by 295
The Sleep of the Ring: Comparison of the ŌURA Sleep Tracker Against Polysomnography
de Zambotti, M., Rosas, L., Colrain, I. M., & Baker, F. C. (2019) · Behavioral Sleep Medicine · doi:10.1080/15402002.2017.1300587 · Cited by 287
“5%), it had lower specificity in detecting wake (48%), similar to findings by us and others for other sleep-trackers (de Zambotti, Baker, et al., 2015; de Zambotti, Baker, et al., 2016; de Zambotti, Claudatos, et al., 2015; Kolla et al., 2016; Montgomery-Downs et al., 2012), and standard actigraphy (Paquet et al.”
ResultDementyev, A., Hodges, S., Taylor, S., & Smith, J. (2013) · 2013 IEEE International Wireless Symposium (IWS) · doi:10.1109/ieee-iws.2013.6616827 · Cited by 272
“Devices such as wearable health monitors often use this scenario when interfacing with a mobile phone-based hub.”
Backgroundde Zambotti, M., Goldstein, C., Cook, J., Menghini, L., Altini, M., Cheng, P., & Robillard, R. (2024) · SLEEP · doi:10.1093/sleep/zsad325 · Cited by 250
Depner, C. M., Cheng, P. C., Devine, J. K., Khosla, S., de Zambotti, M., Robillard, R., Vakulin, A., & Drummond, S. P. A. (2020) · Sleep · doi:10.1093/sleep/zsz254 · Cited by 245
Sleep Quality Prediction From Wearable Data Using Deep Learning
Sathyanarayana, A., Joty, S., Fernandez-Luque, L., Ofli, F., Srivastava, J., Elmagarmid, A., Arora, T., & Taheri, S. (2016) · JMIR mHealth and uHealth · doi:10.2196/mhealth.6562 · Cited by 242
“Recent studies have found that these consumer-grade devices can sometimes have similar precision to clinical-grade actigraphy sensors [31].”
BackgroundMeltzer, L. J., Hiruma, L. S., Avis, K., Montgomery-Downs, H., & Valentin, J. (2015) · Sleep · doi:10.5665/sleep.4918 · Cited by 228
Self-citationde Zambotti, M., Baker, F. C., Willoughby, A. R., Godino, J. G., Wing, D., Patrick, K., & Colrain, I. M. (2016) · Physiology & Behavior · doi:10.1016/j.physbeh.2016.03.006 · Cited by 222
“In studies using the FitbitClassicTM in adults [26] and the FitbitUltraTM in pediatric populations [27], the devices largely overestimated/ underestimated SE (>14%), TST (>60min) and WASO (>50min).”
BackgroundMethodConsumer Sleep Technologies: A Review of the Landscape
Ko, P.-R. T., Kientz, J. A., Choe, E. K., Kay, M., Landis, C. A., & Watson, N. F. (2015) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.5288 · Cited by 211
Kroshus, E., Wagner, J., Wyrick, D., Athey, A., Bell, L., Benjamin, H. J., Grandner, M. A., Kline, C. E., Mohler, J. M., Roxanne Prichard, J., et al. (2019) · British Journal of Sports Medicine · doi:10.1136/bjsports-2019-100590 · Cited by 203
Adam Noah, J., Spierer, D. K., Gu, J., & Bronner, S. (2013) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2013.831135 · Cited by 202
“To date, little research exists about the reliability and validity of the Fitbit [29,30].”
BackgroundOrthosomnia: are some patients taking the quantified self too far?
Baron, K. G., Abbott, S., Jao, N., Manalo, N., & Mullen, R. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6472 · Cited by 188
“3,4 In addition, lack of transparency in the device algorithms makes it impossible to know how accurate they are even under the best circumstances.”
Baron, K. G., Duffecy, J., Berendsen, M. A., Cheung Mason, I., Lattie, E. G., & Manalo, N. C. (2018) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2017.12.002 · Cited by 186
“The majority of studies compared the wearable or mobile sleep tracking technology agains t PSG or EEG (n=14)[14-26] or actigraphy (n=4) [21, 23, 27-29].”
Asgari Mehrabadi, M., Azimi, I., Sarhaddi, F., Axelin, A., Niela-Vilén, H., Myllyntausta, S., Stenholm, S., Dutt, N., Liljeberg, P., & Rahmani, A. M. (2020) · JMIR mHealth and uHealth · doi:10.2196/20465 · Cited by 155
“These studies focused on the sleep quality assessment of wearables by tracking a set of nonstaging sleep parameters, including TST, SOL, WASO, and SE [31-34].”
Highly Wearable, Breathable, and Washable Sensing Textile for Human Motion and Pulse Monitoring
Lou, M., Abdalla, I., Zhu, M., Wei, X., Yu, J., Li, Z., & Ding, B. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c03670 · Cited by 173
Conley, S., Knies, A., Batten, J., Ash, G., Miner, B., Hwang, Y., Jeon, S., & Redeker, N. S. (2019) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2019.05.001 · Cited by 172
Advanced materials of printed wearables for physiological parameter monitoring
Sreenilayam, S. P., Ahad, I. U., Nicolosi, V., Acinas Garzon, V., & Brabazon, D. (2020) · Materials Today · doi:10.1016/j.mattod.2019.08.005 · Cited by 171
Lou, M., Abdalla, I., Zhu, M., Yu, J., Li, Z., & Ding, B. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b19238 · Cited by 169
Consumer sleep tracking devices: a review of mechanisms, validity and utility
Kolla, B. P., Mansukhani, S., & Mansukhani, M. P. (2016) · Expert Review of Medical Devices · doi:10.1586/17434440.2016.1171708 · Cited by 144
Windows into human health through wearables data analytics
Witt, D. R., Kellogg, R. A., Snyder, M. P., & Dunn, J. (2019) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2019.01.001 · Cited by 157
Shin, G., Feng, Y., Jarrahi, M. H., & Gafinowitz, N. (2019) · JAMIA Open · doi:10.1093/jamiaopen/ooy048 · Cited by 143
Validation of Sleep-Tracking Technology Compared with Polysomnography in Adolescents
de Zambotti, M., Baker, F. C., & Colrain, I. M. (2015) · Sleep · doi:10.5665/sleep.4990 · Cited by 160
Lee, X. K., Chee, N. I. Y. N., Ong, J. L., Teo, T. B., van Rijn, E., Lo, J. C., & Chee, M. W. L. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7932 · Cited by 141
Toon, E., Davey, M. J., Hollis, S. L., Nixon, G. M., Horne, R. S. C., & Biggs, S. N. (2016) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.5580 · Cited by 161
“…sleep and wake to an accuracy of 86% when compared to PSG. Consistent with the few previous studies validating commercial accelerometer devices, 18–20 the UP showed greater sensitivity, accurately assessing sleep 92% of the time, than specificity, accurately assessing wake only 66% of the time.”
Fonseca, P., Weysen, T., Goelema, M. S., Møst, E. I. S., Radha, M., Lunsingh Scheurleer, C., van den Heuvel, L., & Aarts, R. M. (2017) · SLEEP · doi:10.1093/sleep/zsx097 · Cited by 148
Kang, S.-G., Kang, J. M., Ko, K.-P., Park, S.-C., Mariani, S., & Weng, J. (2017) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2017.03.009 · Cited by 146
Naslund, J. A., Aschbrenner, K. A., Barre, L. K., & Bartels, S. J. (2015) · Telemedicine and e-Health · doi:10.1089/tmj.2014.0105 · Cited by 144
Chung, C.-F., Cook, J., Bales, E., Zia, J., & Munson, S. A. (2015) · Journal of Medical Internet Research · doi:10.2196/jmir.4364 · Cited by 127
“While systems to support diagnosis and disease management require high-reliability-tracking technology [52], use of engaging, but perhaps less reliable, consumer-centric tracking apps might offer better support for patient-provider communication around routines, values, and priorities.”
Cosoli, G., Spinsante, S., & Scalise, L. (2020) · Measurement · doi:10.1016/j.measurement.2020.107789 · Cited by 119
Overview of smartphone applications for sleep analysis
Ong, A. A., & Gillespie, M. B. (2016) · World Journal of Otorhinolaryngology - Head and Neck Surgery · doi:10.1016/j.wjorl.2016.02.001 · Cited by 123
“22 We were also limited by the information available in the mobile app store and the developer’s website.”
BackgroundSvensson, T., Madhawa, K., Nt, H., Chung, U., & Svensson, A. K. (2024) · Sleep Medicine · doi:10.1016/j.sleep.2024.01.020 · Cited by 139
Past, Present, and Future of Multisensory Wearable Technology to Monitor Sleep and Circadian Rhythms
Lujan, M. R., Perez-Pozuelo, I., & Grandner, M. A. (2021) · Frontiers in Digital Health · doi:10.3389/fdgth.2021.721919 · Cited by 137
“investigated the validity of the original Fitbit Tracker as a tool to classify sleep/wake (54).”
MethodEvaluation of a consumer fitness-tracking device to assess sleep in adults
de Zambotti, M., Claudatos, S., Inkelis, S., Colrain, I. M., & Baker, F. C. (2015) · Chronobiology International · doi:10.3109/07420528.2015.1054395 · Cited by 127
“The epoch-by-epoch comparison between Jawbone UP and PSG data confirms that similar to standard actigraphy (Ancoli-Israel et al., 2003; de Souza et al., 2003; Marino et al., 2013; Sadeh, 2011; Van de Water et al., 2011) and to Fitbit (Montgomery-Downs et al., 2012), Jawbone UP had high sensitivity and low specificity,…”
BackgroundResultInfluentialChinoy, E. D., Cuellar, J. A., Jameson, J., & Markwald, R. R. (2022) · Nature and Science of Sleep · doi:10.2147/nss.s348795 · Cited by 130
Lillehei, A. S., Halcón, L. L., Savik, K., & Reis, R. (2015) · The Journal of Alternative and Complementary Medicine · doi:10.1089/acm.2014.0327 · Cited by 101
Liang, Z., & Martell, M. A. C. (2018) · Journal of Healthcare Informatics Research · doi:10.1007/s41666-018-0013-1 · Cited by 121
Chee, N. I. Y. N., Ghorbani, S., Golkashani, H. A., Leong, R. L. F., Ong, J. L., & Chee, M. W. L. (2021) · Nature and Science of Sleep · doi:10.2147/nss.s286070 · Cited by 120
Wen, D., Zhang, X., Liu, X., & Lei, J. (2017) · Journal of Medical Internet Research · doi:10.2196/jmir.6874 · Cited by 111
“…consistently compared with each other (reliability=96.5%- 99.1%), and they overestimated sleep efficiency by an average of 14.5% compared with PSG [26] Consumer-grade wearable devices performed consistently compared with each other (reliability=96.5-99.1%), and they overestimated sleep time by an…”
InfluentialMaking Sense of Sleep Sensors: How Sleep Sensing Technologies Support and Undermine Sleep Health
Ravichandran, R., Sien, S.-W., Patel, S. N., Kientz, J. A., & Pina, L. R. (2017) · Proceedings of the 2017 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3025453.3025557 · Cited by 95
Godino, J. G., Wing, D., de Zambotti, M., Baker, F. C., Bagot, K., Inkelis, S., Pautz, C., Higgins, M., Nichols, J., Brumback, T., et al. (2020) · PLoS ONE · doi:10.1371/journal.pone.0237719 · Cited by 107
Lee, H.-A., Lee, H.-J., Moon, J.-H., Lee, T., Kim, M.-G., In, H., Cho, C.-H., & Kim, L. (2017) · Psychiatry Investigation · doi:10.4306/pi.2017.14.2.179 · Cited by 100
Cook, J. D., Prairie, M. L., & Plante, D. T. (2017) · Journal of Affective Disorders · doi:10.1016/j.jad.2017.04.030 · Cited by 104
Kalmbach, D. A., Fang, Y., Arnedt, J. T., Cochran, A. L., Deldin, P. J., Kaplin, A. I., & Sen, S. (2018) · Journal of General Internal Medicine · doi:10.1007/s11606-018-4373-2 · Cited by 113
Sleep Tracking, Wearable Technology, and Opportunities for Research and Clinical Care
Shelgikar, A. V., Anderson, P. F., & Stephens, M. R. (2016) · Chest · doi:10.1016/j.chest.2016.04.016 · Cited by 104
“Similar results were seen for validation of Fitbit (see Table 1 for full citation) versus polysomnography in a study of 24 healthy adults aged 19-41 years.(36) In a validation study of the smartphone sleep-tracking app, Sleep Time (Azumio, Inc.”
ResultA Review of Approaches for Sleep Quality Analysis
Mendonca, F., Mostafa, S. S., Morgado-Dias, F., Ravelo-Garcia, A. G., & Penzel, T. (2019) · IEEE Access · doi:10.1109/access.2019.2900345 · Cited by 101
“[106] by comparing the produced analysis with a PSG.”
MethodO’Hare, E., Flanagan, D., Penzel, T., García, C., Frohberg, D., & Heneghan, C. (2014) · Sleep And Breathing · doi:10.1007/s11325-014-0967-z · Cited by 105
Promise of Wearable Physical Activity Monitors in Oncology Practice
Beg, M. S., Gupta, A., Stewart, T., & Rethorst, C. D. (2017) · Journal of Oncology Practice · doi:10.1200/jop.2016.016857 · Cited by 86
“Heart rate and sleep measurements are newer concepts that are being standardized.(6,9) Depending on the objectiveof incorporatingphysical activitymonitors intoclinicor research processes, some devices may therefore be better suited than others, and understanding those nuances is critical before implementation.”
BackgroundKahawage, P., Jumabhoy, R., Hamill, K., de Zambotti, M., & Drummond, S. P. A. (2019) · Journal of Sleep Research · doi:10.1111/jsr.12931 · Cited by 91
O’Driscoll, D. M., Turton, A. R., Copland, J. M., Strauss, B. J., & Hamilton, G. S. (2012) · Sleep And Breathing · doi:10.1007/s11325-012-0662-x · Cited by 95
Accuracy of computer algorithms and the human eye in scoring actigraphy
Boyne, K. L., Sherry, D. D., Gallagher, P. R., Olsen, M. N., & Brooks, L. J. (2012) · Sleep And Breathing · doi:10.1007/s11325-012-0709-z · Cited by 91
Assessment of a wireless headband for automatic sleep scoring
Griessenberger, H., Heib, D. P. J., Kunz, A. B., Hoedlmoser, K., & Schabus, M. (2013) · Sleep and Breathing · doi:10.1007/s11325-012-0757-4 · Cited by 80
Concurrent Validity of Wearable Activity Trackers Under Free-Living Conditions
Brooke, S. M., An, H.-S., Kang, S.-K., Noble, J. M., Berg, K. E., & Lee, J.-M. (2017) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001571 · Cited by 79
Promises and Challenges in the Use of Consumer-Grade Devices for Sleep Monitoring
Roomkham, S., Lovell, D., Cheung, J., & Perrin, D. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2811735 · Cited by 79
“Actigraphy has been shown to be a valid measure of sleep duration [38]–[41].”
BackgroundMethodInfluentialSchyvens, A.-M., Peters, B. T., Oost, N. C. V., Aerts, J., Masci, F., Neven, A., Dirix, H., Wets, G., Ross, V., & Verbraecken, J. A. (2025) · SLEEP Advances · doi:10.1093/sleepadvances/zpaf021 · Cited by 91
Activity trackers, prior motivation, and perceived informational and motivational affordances
Jarrahi, M. H., Gafinowitz, N., & Shin, G. D. (2017) · Personal and Ubiquitous Computing · doi:10.1007/s00779-017-1099-9 · Cited by 89
“tracking activities and by offering real-time data, these devices allow users to manage their overall health more effectively [44, 48].”
BackgroundLiang, Z., & Chapa-Martell, M. A. (2019) · JMIR mHealth and uHealth · doi:10.2196/13384 · Cited by 76
“In response to this need, many studies have examined the accuracy of popular sleep trackers compared with medical devices in terms of aggregated sleep metrics, including TST, wake after sleep onset (WASO), sleep efficiency (SE), and sleep stages, that is, light sleep, deep sleep, and rapid eye movement (REM) sleep [18…”
Performance assessment of new-generation Fitbit technology in deriving sleep parameters and stages
Haghayegh, S., Khoshnevis, S., Smolensky, M. H., Diller, K. R., & Castriotta, R. J. (2020) · Chronobiology International · doi:10.1080/07420528.2019.1682006 · Cited by 74
Consumer Sleep Tracking Devices: A Critical Review
Jeon, L., & Joseph, F. (2015) · Studies in Health Technology and Informatics · doi:10.3233/978-1-61499-512-8-458 · Cited by 66
“Sleep tracking evaluation studies included two articles on BodyMedia [3–4], one article on Fitbit [6] and one article on Zeo [5].”
MethodInfluentialGruwez, A., Bruyneel, A.-V., & Bruyneel, M. (2019) · PLOS ONE · doi:10.1371/journal.pone.0210569 · Cited by 64
Züger, M., Müller, S. C., Meyer, A. N., & Fritz, T. (2018) · Proceedings of the 2018 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3173574.3174165 · Cited by 66
“While the Fitbit’s coarser sampling granularity does not allow measuring HRV [83] and tends to overestimate sleep duration, it has a high intra-device reliability [60] and can be worn constantly (except for charging, showering and swimming) thanks to the minimally invasive form-factor and the built-in memory.”
BackgroundSleepGuard: Capturing Rich Sleep Information Using Smartwatch Sensing Data
Chang, L., Lü, J., Wang, J., Chen, X., Fang, D., Tang, Z., Nurmi, P., & Wang, Z. (2018) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3264908 · Cited by 70
“While the performance of Fitbit is not comparable to medical grade PSG, it has been shown to have a good association in adults [14, 26, 31, 49], especially in estimating REM and light sleep stage.”
BackgroundGusmer, R. J., Bosch, T. A., Watkins, A. N., Ostrem, J. D., & Dengel, D. R. (2014) · The Open Sports Medicine Journal · doi:10.2174/1874387001408010011 · Cited by 59
“Monitoring physical activity is important for assessing activity patterns in populations being studied; however, even more important is the validity of the data being collected [5,6].”
BackgroundArora, A., Chakraborty, P., & Bhatia, M. P. S. (2020) · Arabian Journal for Science and Engineering · doi:10.1007/s13369-020-04877-w · Cited by 62
Teo, J. X., Dávila, S., Yang, C., Hii, A. A., Pua, C. J., Yap, J. J. L., Tan, S. Y., Sahlén, A., Chin, C. W.-L., Teh, B. T., et al. (2019) · Communications Biology · doi:10.1038/s42003-019-0605-1 · Cited by 64
Sleep assessment devices: types, market analysis, and a critical view on accuracy and validation
Valle, V. I.-D., Silva, J., Navarro-Illana, E., & Cauli, O. (2019) · Expert Review of Medical Devices · doi:10.1080/17434440.2019.1693890 · Cited by 63
“All the studies in the table coincide in stating that actigraphy is a useful tool, especially to detect sleep: sensibility is higher than 86% in all studies, but its ability to detect wake is still weak: specificity is below 66% in most cases, and even below 20% in some others [58].”
BackgroundCook, J. D., Eftekari, S. C., Dallmann, E., Sippy, M., & Plante, D. T. (2019) · Journal of Sleep Research · doi:10.1111/jsr.12789 · Cited by 57
Meyer, N., Kerz, M., Folarin, A., Joyce, D. W., Jackson, R., Karr, C., Dobson, R., & MacCabe, J. (2018) · JMIR mHealth and uHealth · doi:10.2196/mhealth.8292 · Cited by 58
“Although some validation data are published from healthy populations showing acceptable agreement between consumer devices to actigraphy for some physical activity measures [54] and sleep [55] and with ECG for heart rate [56,57], no such data are available for populations with psychosis.”
BackgroundSleep apps and the quantified self: blessing or curse?
den Bulck, J. V. (2015) · Journal of Sleep Research · doi:10.1111/jsr.12270 · Cited by 58
“Research has shown that at least one device overestimates sleep time and sleep quality (Montgomery-Downs et al., 2012).”
BackgroundIdentifying Mobile Sensing Indicators of Stress-Resilience
Adler, D. A., Tseng, V. W.-S., Qi, G., Scarpa, J. R., Sen, S., & Choudhury, T. (2021) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3463528 · Cited by 67
“Prior research has examined and determined that Fitbits are an accurate consumer product for tracking sleep, activity, and heart rate for research purposes [17, 60, 63].”
BackgroundWeaver, A. L., Stutzman, S. E., Supnet, C. B., & Olson, D. M. (2015) · International Emergency Nursing · doi:10.1016/j.ienj.2015.08.003 · Cited by 64
“…Sonja E. Stutzman, Charlene Supnet, DaiWai M. Olson, Sleep quality, but not quantity, is associated with self-perceived minor error rates among emergency department nurses, International Emergency Nursing (2015), doi: 10.1016/j.ienj.2015.08.003 sleeping behavior (Montgomery-Downs et al., 2012).”
BackgroundMethodInfluentialSleep-Wake Evaluation from Whole-Night Non-Contact Audio Recordings of Breathing Sounds
Dafna, E., Tarasiuk, A., & Zigel, Y. (2015) · PLoS ONE · doi:10.1371/journal.pone.0117382 · Cited by 60
Rentz, L. E., Ulman, H. K., & Galster, S. M. (2021) · Sensors · doi:10.3390/s21155071 · Cited by 61
“Further, little movement often occurs during this transition, making determinations of sleep onset difficult, which has been well demonstrated across validation studies [64,66,67].”
BackgroundThe Boom in Wearable Technology: Cause for Alarm or Just What is Needed to Better Understand Sleep?
de Zambotti, M., Godino, J. G., Baker, F. C., Cheung, J., Patrick, K., & Colrain, I. M. (2016) · Sleep · doi:10.5665/sleep.6108 · Cited by 50
Effects of Preseason Training on the Sleep Characteristics of Professional Rugby League Players
Thornton, H. R., Delaney, J. A., Duthie, G. M., & Dascombe, B. J. (2017) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2017-0119 · Cited by 58
Peach, H. D., Gaultney, J. F., & Ruggiero, A. R. (2018) · The Journal of Primary Prevention · doi:10.1007/s10935-018-0526-7 · Cited by 55
An automated method for coding sleep states in human infants based on respiratory rate variability
Isler, J. R., Thai, T., Myers, M. M., & Fifer, W. P. (2016) · Developmental Psychobiology · doi:10.1002/dev.21482 · Cited by 57
The Future of Sleep Measurements
Arnardóttir, E. S., Íslind, A. S., & Óskarsdóttir, M. (2021) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2021.05.004 · Cited by 64
Svensson, T., Chung, U., Tokuno, S., Nakamura, M., & Svensson, A. K. (2019) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2019.109822 · Cited by 56
Towards Benchmarked Sleep Detection with Wrist-Worn Sensing Units
Borazio, M., Berlin, E., Kucukyildiz, N., Scholl, P., & Van Laerhoven, K. (2014) · 2014 IEEE International Conference on Healthcare Informatics · doi:10.1109/ichi.2014.24 · Cited by 50
“, [5], which compares the fitbit to a commonly used actigraph for sleep evaluation).”
BackgroundHow well does a commercially available wearable device measure sleep in young athletes?
Sargent, C., Lastella, M., Romyn, G., Versey, N., Miller, D. J., & Roach, G. D. (2018) · Chronobiology International · doi:10.1080/07420528.2018.1466800 · Cited by 45
“Like most accelerometer-based devices (Kosmadopoulos et al. 2014; Montgomery-Downs et al. 2012; Zambotti et al. 2015), the device in this study overestimated TST compared with PSG.”
MethodCook, J. D., Prairie, M. L., & Plante, D. T. (2018) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7120 · Cited by 54
“1 10 These mass-marketed devices are continuing to gain popularity in both general and patient populations, and may have utility in the clinical assessment of patients.”
Sleep Validity of a Non-Contact Bedside Movement and Respiration-Sensing Device
Schade, M. M., Bauer, C. E., Murray, B. R., Gahan, L., Doheny, E. P., Kilroy, H., Zaffaroni, A., & Montgomery‐Downs, H. E. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7892 · Cited by 52
“To display concordance between PSG and each device, we used a modified Bland-Altman plotting technique, 9 where PSG is considered the gold standard for comparison, rather than plotting the test devices against an average of the test device and PSG. 29 This approach highlights absolute differences…”
Self-citationSleep classification using Consumer Sleep Technologies and AI: A review of the current landscape
Djanian, S., Bruun, A., & Nielsen, T. D. (2022) · Sleep Medicine · doi:10.1016/j.sleep.2022.09.004 · Cited by 63
“For sleep/wake classi fi cation it can be seen that out of the 5 studies that have above 90% above accuracy 3 of them combine PPG with an accelerometer.”
InfluentialPaton, C., Hansen, M. M., Fernández-Luque, L., & Lau, A. Y. S. (2012) · PubMed · Cited by 59
Metadata
- Authors
- Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A.
- Affiliations
- West Virginia University (US)
- Venue
- Sleep and Breathing
- Published
- 2011-10-06
- Volume
- 16
- Issue
- 3
- Pages
- 913-917
- ISSN
- 1520-9512 (ISSN-L)
- 1522-1709
- OpenAlex
- W2112783455
- Cited by
- 301
- References
- 6
- Citations by year
- 2026: 3 · 2025: 9 · 2024: 16 · 2023: 10 · 2022: 25 · 2021: 17 · 2020: 29 · 2019: 51 · 2018: 29 · 2017: 33 · 2016: 26 · 2015: 28 · 2014: 16 · 2013: 4 · 2012: 5
- FWCI
- 10.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Sleep And Breathing (publishedVersion)
- PubMed (publishedVersion)
- Funders
- West Virginia University
- Topics
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Circadian rhythm and melatonin
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Keywords
- Fitbit, activity monitoring, actigraphy, polysomnography, sleep efficiency, total sleep time, device reliability, device validity, sleep disorders, wearable devices
- MeSH terms
- Adult, Arousal, Equipment Design, Female, Humans, Male, Signal Processing, Computer-Assisted, Sleep Wake Disorders, Sleep Stages, Wakefulness, Reproducibility of Results, Polysomnography, Monitoring, Ambulatory, Young Adult, Actigraphy, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.