CoChat

Rates of initial acceptance of PAP masks and outcomes of mask switching

Open access
Bachour, Adel, Vitikainen, Pirjo, Maasilta, Paula · 2016 · Sleep and Breathing

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

Purpose Recently, we noticed a considerable development in alleviating problems related to positive airway pressure (PAP) masks. In this study, we report on the initial PAP mask acceptance rates and the effects of mask switching on mask-related symptoms.Methods We prospectively collected all cases of mask switching in our sleep unit for a period of 14 months. At the time of the study, we used ResMed™ CPAP devices and masks. Mask switching was defined as replacing a mask used for at least 1 day with another type of mask. Changing to a different size but keeping the same type of mask did not count as mask switching. Switching outcomes were considered failed if the initial problem persisted or reappeared during the year that followed switching.Results Our patient pool was 2768. We recorded 343 cases of mask switching among 267 patients. Of the 566 patients who began new PAP therapy, 108 (39 women) had switched masks, yielding an initial mask acceptance rate of 81 %. The reason for switching was poor-fit/uncomfortable mask in 39 %, leak-related in 30 %, outdated model in 25 %, and nasal stuffiness in 6 % of cases; mask switching resolved these problems in 61 %. Mask switching occurred significantly (p = 0.037) more often in women and in new PAP users. The odds ratio for abandoning PAP therapy within 1 year after mask switching was 7.2 times higher (interval 4.7-11.1) than not switching masks.Conclusion The initial PAP mask acceptance rate was high. Patients who switched their masks are at greater risk for abandoning PAP therapy.

Overview

Integrity signals

Registry

Crossref · 10.1007/s11325-015-1292-x

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 14 references

Cited by

See all 48

Metadata

Authors
Bachour, A., Vitikainen, P., & Maasilta, P.
Affiliations
University of Helsinki (FI)
Corresponding author
Bachour, Adel
Venue
Sleep and Breathing
Published
2015-12-10
Volume
20
Issue
2
Pages
733-738
ISSN
  • 1520-9512 (ISSN-L)
  • 1522-1709
OpenAlex
W2292457420
Cited by
48
References
14
Citations by year
2026: 2 · 2024: 4 · 2023: 1 · 2022: 2 · 2021: 19 · 2020: 6 · 2019: 4 · 2018: 3 · 2017: 3 · 2016: 4
FWCI
2.45
Type
journal article
Language
en
Open access
Licence
  • other-oa
  • www.springer.com/tdm (tdm)
Locations
  • Sleep And Breathing (publishedVersion)
  • PubMed (publishedVersion)
  • Työväentutkimus Vuosikirja (submittedVersion, other-oa)
Funders
Helsinki University Special Fund (V1016SK001)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
Keywords
continuous positive airway pressure, mask acceptance, mask fit, mask leak, nasal obstruction, sex differences
MeSH terms
Adult, Aged, Equipment Design, Female, Follow-Up Studies, Humans, Male, Masks, Middle Aged, Patient Acceptance of Health Care, Patient Dropouts, Prospective Studies, Risk Factors, Odds Ratio, Polysomnography, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rates of initial acceptance of PAP masks and outcomes of mask switching. https://app.cochat.ai/papers/10.1007/s11325-015-1292-x
The paper
Bachour, A., Vitikainen, P., & Maasilta, P. (2016). Rates of initial acceptance of PAP masks and outcomes of mask switching. Sleep and Breathing. https://doi.org/10.1007/s11325-015-1292-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.