Cited by 33Adsorption and biosorption for pollutant removalHeavy Metal Pollution RemediationCoagulation and Flocculation Studies

Biosorption of Cu (II) by immobilized microalgae using silica: kinetic, equilibrium, and thermodynamic study

Lee, Hongkyun, Shim, Eunjung, Yun, Hyun-Shik, Park, Young-Tae, Kim, Dohyeong, Ji, Min-Kyu, Kim, Chi-Kyung, Shin, Won-Sik +1 more·2016·Environmental Science and Pollution Research

Abstract

Immobilized microalgae using silica (IMS) from Micractinium reisseri KGE33 was synthesized through a sol-gel reaction. Green algal waste biomass, the residue of M. reisseri KGE33 after oil extraction, was used as the biomaterial. The adsorption of Cu(II) on IMS was tested in batch experiments with varying algal doses, pH, contact times, initial Cu(II) concentrations, and temperatures. Three types of IMSs (IMS 14, 70, and 100) were synthesized according to different algal doses. The removal efficiency of Cu(II) in the aqueous phase was in the following order: IMS 14 (77.0%) < IMS 70 (83.3%) < IMS 100 (87.1%) at pH 5. The point of zero charge (PZC) value of IMS100 was 4.5, and the optimum pH for Cu(II) adsorption was 5. Equilibrium data were described using a Langmuir isotherm model. The Langmuir model maximum Cu(II) adsorption capacity (q m) increased with the algal dose in the following order: IMS 100 (1.710 mg g(-1)) > IMS 70 (1.548 mg g(-1)) > IMS 14 (1.282 mg g(-1)). The pseudo-second-order equation fitted the kinetics data well, and the value of the second-order rate constant increased with increasing algal dose. Gibbs free energies (ΔG°) were negative within the temperature range studied, which indicates that the adsorption process was spontaneous. The negative value of enthalpy (ΔH°) again indicates the exothermic nature of the adsorption process. In addition, SEM-energy-dispersive X-ray spectroscopy (EDS), Fourier transform infrared (FT-IR), and X-ray photoelectron spectroscopy (XPS) analyses of the IMS surface reveal that the algal biomass on IMS is the main site for Cu(II) binding. This study shows that immobilized microalgae using silica, a synthesized biosorbent, can be used as a cost-effective sorbent for Cu(II) removal from the aqueous phase.

Integrity signals

Registry

Crossref · 10.1007/s11356-015-4609-1

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lee, H., Shim, E., Yun, H.-S., Park, Y.-T., Kim, D., Ji, M.-K., Kim, C.-K., Shin, W.-S., & Choi, J.
Affiliations
  • Korean Association Of Science and Technology Studies (KR)
  • Yonsei University (KR)
  • Kyungpook National University (KR)
Corresponding author
Choi, Jaeyoung
Venue
Environmental Science and Pollution Research
Published
2015-05-09
Volume
23
Issue
2
Pages
1025-1034
ISSN
  • 0944-1344 (ISSN-L)
  • 1614-7499
OpenAlex
W261893115
Cited by
33
References
43
Citations by year
2026: 2 · 2025: 2 · 2024: 2 · 2023: 3 · 2022: 4 · 2021: 7 · 2019: 4 · 2018: 5 · 2017: 2 · 2016: 2
FWCI
1.99
Type
journal article
Language
en
Open access
closed
Locations
  • Environmental Science and Pollution Research (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Environmental Science › Water Science and Technology › Adsorption and biosorption for pollutant removal
  • Physical Sciences › Environmental Science › Water Science and Technology › Heavy Metal Pollution Remediation
  • Physical Sciences › Environmental Science › Water Science and Technology › Coagulation and Flocculation Studies
Keywords
biosorption, copper removal, immobilized microalgae, silica, sol-gel synthesis, Langmuir isotherm, pseudo-second-order kinetics, adsorption thermodynamics, point of zero charge, heavy metal removal from water, biosorbent
MeSH terms
Adsorption, Chlorophyta, Copper, Hydrogen-Ion Concentration, Kinetics, Silicon Dioxide, Temperature, Thermodynamics, Water, Water Pollutants, Chemical, Spectroscopy, Fourier Transform Infrared, Biomass, Photoelectron Spectroscopy, Microalgae

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review