Student or educator? Sign up with your school email and get 6 months of Pro free.

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Potentiometric polyphenol oxidase biosensor for sensitive determination of phenolic micropollutant in environmental samples

Abstract

The present study demonstrates the development of polyphenol oxidase (PPO) biosensor for the detection of catechol using strontium copper oxide (SrCuO 2) and polypyrrole nanotubes (PPyNT) matrix. The SrCuO 2 micro-seeds, a perovskite compound, are synthesized by co-precipitation under pH 8.0. The as-synthesized micro-seeds are characterized by scanning electron microscopy (SEM), field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDX), and X-ray diffraction spectroscopy (XRD). The proposed sensor is fabricated on pencil graphite (P-Gr) by successive deposition of PPyNT, SrCuO 2, and PPO enzyme. The developed PPO/SrCuO 2/PPyNT/P-Gr sensor is characterized by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS) techniques. The PPO/SrCuO 2/PPyNT/P-Gr displayed excellent electrocatalytic activity towards the oxidation and detection of catechol. The as-developed sensor showed sensitive response ascribing to limit of detection (LOD) of 0.15 μM and sensitivity of 15.60 μA μM-1 cm-2. The fabricated sensor exhibited excellent repeatability and longer shelf life. The proposed biosensor finds its application within the broad linear range of 1-50 μM. Real sample analysis of mineral water, tap water, and domestic wastewater using developed sensor showed acceptable recovery. Hence, the biosensor endeavors its application in environmental monitoring and protection.

Overview

Integrity signals

Registry

Crossref · 10.1007/s11356-019-05495-2

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 41 references

Research works printed but not linked: 1

  1. Swamy NK, Sandeep S, Santhosh AS (2017) Conductive polymers and their nanohybrid transducers for electrochemical biosensors applications : a brief review. J Adv Chem Sci S2:6–9. https://doi.org/10.22607/IJACS.2017.S02002 · doi:10.22607/ijacs.2017.s02002

Cited by

See all 29

Metadata

Authors
Yashas, S. R., Sandeep, S., Shivakumar, B. P., & Swamy, N. K.
Affiliations
JSS Science and Technology University (IN)
Corresponding author
Swamy, Ningappa Kumara
Venue
Environmental Science and Pollution Research
Published
2019-05-27
Volume
27
Issue
22
Pages
27234-27243
ISSN
  • 0944-1344 (ISSN-L)
  • 1614-7499
OpenAlex
W2947108521
Cited by
29
References
41
Citations by year
2026: 1 · 2025: 4 · 2024: 5 · 2023: 1 · 2022: 9 · 2021: 5 · 2020: 2 · 2019: 2
FWCI
1.62
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • Environmental Science and Pollution Research (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
catechol detection, polypyrrole nanotubes, pencil graphite electrode, electrocatalytic oxidation, potentiometric sensing, domestic wastewater, drinking water analysis, environmental monitoring
MeSH terms
Catechol Oxidase, Electrodes, Graphite, Polymers, Pyrroles, Biosensing Techniques, Electrochemical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Potentiometric polyphenol oxidase biosensor for sensitive determination of phenolic micropollutant in environmental samples. https://app.cochat.ai/papers/10.1007/s11356-019-05495-2
The paper
Yashas, S. R., Sandeep, S., Shivakumar, B. P., & Swamy, N. K. (2020). Potentiometric polyphenol oxidase biosensor for sensitive determination of phenolic micropollutant in environmental samples. Environmental Science and Pollution Research. https://doi.org/10.1007/s11356-019-05495-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.