Bio-signal based elbow angle and torque simultaneous prediction during isokinetic contraction
The DOI matches its Crossref record; 37 of the 38 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A tutorial on support vector regression
Smola, A. J., & Schölkopf, B. (2004) · Statistics and Computing · doi:10.1023/b:stco.0000035301.49549.88 · Cited by 13,387
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
Diagnostic Ultrasound Imaging: Inside Out
(2014) · Elsevier eBooks · doi:10.1016/c2011-0-07261-7 · Cited by 1,093
Measurement of muscle contraction with ultrasound imaging
Hodges, P. W., Pengel, L. H. M., Herbert, R. D., & Gandevia, S. C. (2003) · Muscle & Nerve · doi:10.1002/mus.10375 · Cited by 816
Myoelectric signal processing for control of powered limb prostheses
Parker, P., Englehart, K., & Hudgins, B. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.08.006 · Cited by 651
1997 IEEE International Conference on Systems, Man and Cybernetics
理文, 吉. (1998) · システム/制御/情報 : システム制御情報学会誌 · doi:10.11509/isciesci.42.3_171_1 · Cited by 624
Quantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443
Linear and Nonlinear Regression Techniques for Simultaneous and Proportional Myoelectric Control
Hahne, J. M., Biebmann, F., Jiang, N., Rehbaum, H., Farina, D., Meinecke, F. C., Muller, K.-R., & Parra, L. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305520 · Cited by 365
The Isokinetic Concept of Exercise
Hislop, H. J., & Perrine, J. (1967) · Physical Therapy · doi:10.1093/ptj/47.1.114 · Cited by 359
Measurement of lumbar multifidus muscle contraction with rehabilitative ultrasound imaging
Kiesel, K. B., Uhl, T. L., Underwood, F. B., Rodd, D. W., & Nitz, A. J. (2007) · Manual Therapy · doi:10.1016/j.math.2006.06.011 · Cited by 292
Cited by
Estimation of joint torque in dynamic activities using wearable A-mode ultrasound
Jin, Y., Alvarez, J. T., Suitor, E. L., Swaminathan, K., Chin, A., Civici, U. S., Nuckols, R. W., Howe, R. D., & Walsh, C. J. (2024) · Nature Communications · doi:10.1038/s41467-024-50038-0 · Cited by 58
Fatigue-Sensitivity Comparison of sEMG and A-Mode Ultrasound based Hand Gesture Recognition
Zeng, J., Zhou, Y., Yang, Y., Yan, J., & Liu, H. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3122277 · Cited by 47
Self-citationFeature Fusion of sEMG and Ultrasound Signals in Hand Gesture Recognition
Zeng, J., Zhou, Y., Yang, Y., Wang, J., & Liu, H. (2020) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc42975.2020.9282818 · Cited by 27
“As ultrasound has the advantages of high detection accuracy and high spatial and temporal resolution [9], [10], it can detect the morphological changes of the surface and deep muscles, which make it better to reflect the muscle contractions and map them to gestures.”
BackgroundSelf-citationSheng, Y., Tan, G., Liu, J., Chang, H., Wang, J., Xie, Q., & Liu, H. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3161726 · Cited by 26
“As a bioelectrical signal used to detect the neuromuscular system, surface electromyography (sEMG) has widely applied in the fields of rehabilitation medicine and sports science [10]–[14].”
MethodSelf-citationMetric-Based Muscle Synergy Consistency for Upper Limb Motor Functions
Sheng, Y., Zeng, J., Liu, J., & Liu, H. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3132345 · Cited by 29
Self-citationGuo, B., Ma, Y., Yang, J., Wang, Z., & Zhang, X. (2020) · Computational Intelligence and Neuroscience · doi:10.1155/2020/8846021 · Cited by 28
“Previous researchers [31, 32] used the traditional SVM algorithm for upper-limb motion intent recognition and applied it in upper-limb rehabilitation robots.”
MethodLei, G., Zhang, S., Fang, Y., Wang, Y., & Zhang, X. (2021) · Sensors · doi:10.3390/s21113872 · Cited by 17
A Real-Time Control Method for Upper Limb Exoskeleton Based on Active Torque Prediction Model
Li, S., Zhang, L., Meng, Q., & Yu, H. (2023) · Bioengineering · doi:10.3390/bioengineering10121441 · Cited by 16
“In general, models were considered to perform well if the ratio of the RMSE to the actual torque mean was less than 15% and the R 2 was greater than 0.9 [36].”
MethodInfluentialsEMG-Driven Functional Electrical Stimulation Tuning via Muscle Force
Zhou, Y., Zeng, J., Li, K., Hargrove, L. J., & Liu, H. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3026280 · Cited by 15
“[16] and to be the feedback for FES intensity tuning in some studies [17]–[19].”
BackgroundSelf-citationMusculoskeletal Joint Angle Estimation Based on Isokinetic Motor Coordination
Sheng, Y., Liu, J., Zhou, Z., Chen, H., & Liu, H. (2021) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2021.3122931 · Cited by 14
“Different from some machine learning algorithms on motion decoding and prediction using bio-signals [16], [26], [27], MSM does not require training set and allows human movement analysis from the viewpoint of muscle physiology [28], [29].”
BackgroundSelf-citationBrausch, L., Hewener, H., & Lukowicz, P. (2022) · Sensors · doi:10.3390/s22072789 · Cited by 15
“Another publication from the same year found that angles and torques of elbows could be reconstructed from 1-D SMG signals using SVM models [17].”
MethodZhang, Q., Fragnito, N., Bao, X., & Sharma, N. (2022) · Wearable Technologies · doi:10.1017/wtc.2022.18 · Cited by 14
“, 2020), as well as continuous kinematics or kinetics prediction (also known as regression problems) based on sEMG signals (Zhang et al., 2012; Zhou et al., 2019; Zhang et al., 2020a; Wang et al., 2021; Yu et al., 2021; Zhang et al., 2022a) and US signals (Guo et al.”
BackgroundRobustness of Combined sEMG and Ultrasound Modalities Against Muscle Fatigue in Force Estimation
Zeng, J., Zhou, Y., Yang, Y., Xu, Z., Zhang, H., & Liu, H. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-89134-3_20 · Cited by 13
Self-citationStudy on the Control Method of Knee Joint Human–Exoskeleton Interactive System
Wang, Z., Yang, C., Ding, Z., Yang, T., Guo, H. Y., Jiang, F., & Tian, B. (2022) · Sensors · doi:10.3390/s22031040 · Cited by 11
“Similarly, sEMG and A-mode ultrasound [21] have been combined and introduced to build a vector machine regression model.”
MethodGuo, W., Wang, M., Sheng, X., & Zhu, X. (2022) · Science China Technological Sciences · doi:10.1007/s11431-022-2035-9 · Cited by 11
“The decoding of human intentions through hand gesture recognition is of great importance for intuitive human-machine interaction (HMI) leveraged to control exoskeletons [1,2], prostheses [3–6], wheelchairs [7], rehabilitation equipment [8], silent speech recognition [9], and teleoperation [10].”
BackgroundChen, S., Peng, C., Yang, B., Lin, J., Zhou, L., Jiang, Z., Liu, Z., Liu, Y., & Tang, L. (2026) · npj Artificial Intelligence · doi:10.1038/s44387-026-00083-5 · Cited by 9
Underwater sEMG-based recognition of hand gestures using tensor decomposition
Xue, J., Sun, Z., Duan, F., Caiafa, C. F., & Solé‐Casals, J. (2022) · Pattern Recognition Letters · doi:10.1016/j.patrec.2022.11.021 · Cited by 9
Upper-limb functional assessment after stroke using mirror contraction: A pilot study
Zhou, Y., Zeng, J., Jiang, H., Li, Y., Jia, J., & Liu, H. (2020) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2020.101877 · Cited by 10
Self-citationSimultaneous Estimation of Upper Limb Pose and Joint Torque Based on Upper Arm Deformation
Kurasumi, T., Cho, S.-G., Ding, M., Ricardez, G. A. G., Yoshikawa, M., Takamatsu, J., & Ogasawara, T. (2020) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2020.3009861 · Cited by 9
“[14] estimate the elbow joint angle and torque using sEMG and”
MethodXu, S., & Ding, Y. (2021) · Science China Technological Sciences · doi:10.1007/s11431-020-1802-2 · Cited by 5
Guo, Q., Li, W., Li, G., Wang, K., Guo, X., Zhang, M., Li, Y., & Wong, W. (2020) · Macromolecular Rapid Communications · doi:10.1002/marc.202000170 · Cited by 5
Hand Grip Force Enhancer Based on sEMG- Triggered Functional Electrical Stimulation
Zeng, J., Zhou, Y., Yang, Y., & Liu, H. (2019) · IEEE International Conference on Cyber Technology in Automation, Control, and Intelligent Systems · doi:10.1109/cyber46603.2019.9066744 · Cited by 3
“According to [6]–[8], EMG-triggered electrical stimulation may be more effective than non-triggered electrical stimulation in facilitating the hand functions in stroke patients in terms of muscle strength and voluntary muscle contraction of the paretic hand and arm.”
BackgroundSelf-citationEstimating voluntary elbow torque from biceps brachii electromyography using a particle filter
Chatfield, L. T., Pretty, C. G., Fortune, B. C., McKenzie, L. R., Whitwham, G. H., & Hayes, M. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102475 · Cited by 3
ELBOW ANGLE ESTIMATION FROM EMG SIGNALS BASED ON MONTE CARLO SIMULATION
Rulaningtyas, R., Zuchruf, Y. M., Rahmatillah, A., Ain, K., Putra, A. P., Rahma, O. N., Salamat, L., & Chai, R. (2022) · Jurnal Teknologi · doi:10.11113/jurnalteknologi.v84.17683 · Cited by 3
“Zhou et al [12] tried to apply the support vector machine (SVM) regression model to predict the position of the forearm.”
MethodFinger Position and Force Simultaneous Prediction Using A-mode Ultrasound
Zhou, Y., Zeng, J., Yang, Y., & Liu, H. (2019) · IEEE International Conference on Cyber Technology in Automation, Control, and Intelligent Systems · doi:10.1109/cyber46603.2019.9066684 · Cited by 3
Self-citationYeon, S. H., Song, H., & Herr, H. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9629789 · Cited by 2
Zhou, Z., Wan, Y., Su, Y., Li, Y., Hu, B., & Yu, H. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1430372 · Cited by 1
“While the biometric signal-based method is more accurate, it requires additional biometric signal detection equipment, which adds inconvenience of wearing and production cost (Zhou et al., 2019).”
MethodFES Proportional Tuning Based on sEMG
Zhou, Y., Zeng, J., Li, K., & Liu, H. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-27538-9_18
Self-citationZhang, Q., Hakam, N., Akinniyi, O. T., Iyer, A., Bao, X., & Sharma, N. (2024) · Scientific Data · doi:10.1038/s41597-024-04285-x
Correlation of Surface Acoustic Wave (SAW) force myography sensor output with elbow joint torque
Kohler, M. C., Rothstein, A., Greenberg, E. T., Voiculescu, I., Tiwale, N. M., & Li, F. (2026) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2026.100974
Metadata
- Authors
- Zhou, Y., Liu, J., Zeng, J., Li, K., & Liu, H.
- Affiliations
- Shanghai Jiao Tong University (CN)
- University of Portsmouth (GB)
- Corresponding author
- Liu, Honghai
- Venue
- Science China Technological Sciences
- Published
- 2018-12-04
- Volume
- 62
- Issue
- 1
- Pages
- 21-30
- ISSN
- 1869-1900 (ISSN-L)
- 1674-7321
- OpenAlex
- W2902356678
- Cited by
- 30
- References
- 38
- Citations by year
- 2026: 2 · 2024: 3 · 2023: 1 · 2022: 7 · 2021: 8 · 2020: 6 · 2019: 3
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Science China Technological Sciences (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Mechanics and Biomechanics Studies
- Keywords
- isokinetic contraction, surface electromyography, A-mode ultrasound, muscle deformation, support vector regression
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.