Snakes based segmentation of the common carotid artery intima media
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Ultrasound measurements of the human carotid artery walls are conventionally obtained by manually tracing interfaces between tissue layers. In this study we present a snakes segmentation technique for detecting the intima-media layer of the far wall of the common carotid artery (CCA) in longitudinal ultrasound images, by applying snakes, after normalization, speckle reduction, and normalization and speckle reduction. The proposed technique utilizes an improved snake initialization method, and an improved validation of the segmentation method. We have tested and clinically validated the segmentation technique on 100 longitudinal ultrasound images of the carotid artery based on manual measurements by two vascular experts, and a set of different evaluation criteria based on statistical measures and univariate statistical analysis. The results showed that there was no significant difference between all the snakes segmentation measurements and the manual measurements. For the normalized despeckled images, better snakes segmentation results with an intra-observer error of 0.08, a coefficient of variation of 12.5%, best Bland–Altman plot with smaller differences between experts (0.01, 0.09 for Expert1 and Expert 2, respectively), and a Hausdorff distance of 5.2, were obtained. Therefore, the pre-processing of ultrasound images of the carotid artery with normalization and speckle reduction, followed by the snakes segmentation algorithm can be used successfully in the measurement of IMT complementing the manual measurements. The present results are an expansion of data published earlier as an extended abstract in IFMBE Proceedings (Loizou et al. IEEE Int X Mediterr Conf Medicon Med Biol Eng POS-03 499:1–4, 2004).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A Threshold Selection Method from Gray-Level Histograms
Otsu, N. (1979) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1979.4310076 · Cited by 43,398 · cited 2×
“The threshold is chosen so that the intraclass variance [26] of the”
BackgroundMethodKass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070 · cited 2×
“The snakes segmentation technique implemented in this study is based on an energy function as defined by Williams and Shah [36], which is an extension of the initial snake functional defined by Kass et al. [ 13 ].”
BackgroundMethod(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Digital Image Enhancement and Noise Filtering by Use of Local Statistics
Lee, J.-S. (1980) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1980.4766994 · Cited by 2,728 · cited 2×
“The lsmv filter may be described by a weighted average calculation using sub region statistics to estimate statistical measurements over 7 · 7 pixel windows [16, 18].”
MethodIntimal plus medial thickness of the arterial wall: a direct measurement with ultrasound imaging.
Pignoli, P., Tremoli, E., Poli, A., Oreste, P., & Paoletti, R. (1986) · Circulation · doi:10.1161/01.cir.74.6.1399 · Cited by 2,404
Bots, M. L., Hoes, A. W., Koudstaal, P. J., Hofman, A., & Grobbee, D. E. (1997) · Circulation · doi:10.1161/01.cir.96.5.1432 · Cited by 2,345 · cited 4×
“This is particular so if plaques develop internal pools of lipid covered only by a thin fibrous cap [3, 15].”
BackgroundInfluentialOn active contour models and balloons
Cohen, L. D. (1991) · CVGIP: Image Understanding · doi:10.1016/1049-9660(91)90028-n · Cited by 2,153 · cited 1×
“(4) The snake is implemented as a close contour [8, 36, 40] that might not be that suitable for the IMC segmentation.”
BackgroundA Fast algorithm for active contours and curvature estimation
Williams, D. J., & Shah, M. (1992) · CVGIP: Image Understanding · doi:10.1016/1049-9660(92)90003-l · Cited by 1,101 · cited 17×
“(4) The snake is implemented as a close contour [8, 36, 40] that might not be that suitable for the IMC segmentation.”
BackgroundMethodInfluentialGradient vector flow: a new external force for snakes
Xu, C., & Prince, J. L. (2002) · Proceedings of IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.1997.609299 · Cited by 751 · cited 1×
“additional image energy term, Eimage (v) [38], which is given by the negative gradient of the current contour point gi,j as Eimage (v) = gi,j(2), was added to our energy functional, as also proposed in [39].”
Background
Cited by
Comparative evaluation of despeckle filtering in ultrasound imaging of the carotid artery
Loizou, C. P., Pattichis, C. S., Christodoulou, C. I., Istepanian, R. S. H., Pantziaris, M., & Nicolaides, A. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1561621 · Cited by 323
Self-citation
Metadata
- Authors
- Loizou, C. P., Pattichis, C. S., Pantziaris, M., Tyllis, T., & Nicolaides, A.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2007-01-03
- Volume
- 45
- Issue
- 1
- Pages
- 35-49
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2002854663
- Cited by
- 227
- References
- 33
- FWCI
- 20.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.