Measurement of functional microcirculatory geometry and velocity distributions using automated image analysis
Open accessAbstract
This study describes a new method for analyzing microcirculatory videos. It introduces algorithms for quantitative assessment of vessel length, diameter, the functional microcirculatory density distribution and red blood-cell (RBC) velocity in individual vessels as well as its distribution. The technique was validated and compared to commercial software. The method was applied to the sublingual microcirculation in a healthy volunteer and in a patient during cardiac surgery. Analysis time was reduced from hours to minutes compared to previous methods requiring manual vessel identification. Vessel diameter was detected with high accuracy (>80%, d > 3 pixels). Capillary length was estimated within 5 pixels accuracy. Velocity estimation was very accurate (>95%) in the range [2.5, 1,000] pixels/s. RBC velocity was reduced by 70% during the first 10 s of cardiac luxation. The present method has been shown to be fast and accurate and provides increased insight into the functional properties of the microcirculation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Cited by
Hemodynamic coherence and the rationale for monitoring the microcirculation
Ince, C. (2015) · Critical Care · doi:10.1186/cc14726 · Cited by 611
Self-citationESICM, O. B. O. T. C. D. S. O. T., Ince, C., Boerma, E. C., Cecconi, M., De Backer, D., Shapiro, N. I., Duranteau, J., Pinsky, M. R., Artigas, A., Teboul, J.-L., et al. (2018) · Intensive Care Medicine · doi:10.1007/s00134-018-5070-7 · Cited by 480
Self-citationKanoore Edul, V. S., Enrico, C., Laviolle, B., Risso Vazquez, A., Ince, C., & Dubin, A. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e31823dae59 · Cited by 274
Self-citationMicrocirculation: Physiology, Pathophysiology, and Clinical Application
Guven, G., Hilty, M. P., & Ince, C. (2020) · Blood Purification · doi:10.1159/000503775 · Cited by 264
Self-citationMicrocirculatory Differences in Children With Congenital Heart Disease According to Cyanosis and Age
González, R., Urbano, J., Solana, M. J., Hervías, M., Pita, A., Pérez, R., Álvarez, R., Teigell, E., Gil-Jaurena, J.-M., Zamorano, J., et al. (2019) · Frontiers in Pediatrics · doi:10.3389/fped.2019.00264 · Cited by 8
Metadata
- Authors
- Dobbe, J. G. G., Streekstra, G. J., Atasever, B., van Zijderveld, R., & Ince, C.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2008-04-22
- Volume
- 46
- Issue
- 7
- Pages
- 659-70
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W4238566795
- Cited by
- 217
- References
- 2
- FWCI
- 10.51
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of functional microcirculatory geometry and velocity distributions using automated image analysis. https://app.cochat.ai/papers/10.1007/s11517-008-0349-4
- The paper
- Dobbe, J. G. G., Streekstra, G. J., Atasever, B., van Zijderveld, R., & Ince, C. (2008). Measurement of functional microcirculatory geometry and velocity distributions using automated image analysis. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-008-0349-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.