Ambulatory human motion tracking by fusion of inertial and magnetic sensing with adaptive actuation
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Over the last years, inertial sensing has proven to be a suitable ambulatory alternative to traditional human motion tracking based on optical position measurement systems, which are generally restricted to a laboratory environment. Besides many advantages, a major drawback is the inherent drift caused by integration of acceleration and angular velocity to obtain position and orientation. In addition, inertial sensing cannot be used to estimate relative positions and orientations of sensors with respect to each other. In order to overcome these drawbacks, this study presents an Extended Kalman Filter for fusion of inertial and magnetic sensing that is used to estimate relative positions and orientations. In between magnetic updates, change of position and orientation are estimated using inertial sensors. The system decides to perform a magnetic update only if the estimated uncertainty associated with the relative position and orientation exceeds a predefined threshold. The filter is able to provide a stable and accurate estimation of relative position and orientation for several types of movements, as indicated by the average rms error being 0.033 m for the position and 3.6 degrees for the orientation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647 · cited 1×
“Although the integration drift can be reduced by using suitable estimation algorithms [7, 10, 13, 23], by using the orientations of individual body segments in a linked segment model [11, 24], or by applying suitable initial and final conditions and a limited integration time [17, 20], a stable and…”
MethodSelf-citation
Cited by
The use of inertial sensors system for human motion analysis
Cuesta-Vargas, A. I., Galán-Mercant, A., & Williams, J. M. (2010) · Physical Therapy Reviews · doi:10.1179/1743288x11y.0000000006 · Cited by 369
Survey of Motion Tracking Methods Based on Inertial Sensors: A Focus on Upper Limb Human Motion
Filippeschi, A., Schmitz, N., Miezal, M., Bleser, G., Ruffaldi, E., & Stricker, D. (2017) · Sensors · doi:10.3390/s17061257 · Cited by 361
Bergamini, E., Ligorio, G., Summa, A., Vannozzi, G., Cappozzo, A., & Sabatini, A. (2014) · Sensors · doi:10.3390/s141018625 · Cited by 267
Wearable Inertial Sensors for Human Motion Analysis: A Review
Lopez-Nava, I. H., & Munoz-Melendez, A. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2609392 · Cited by 263
Schall, M. C., Fethke, N. B., Chen, H., Oyama, S., & Douphrate, D. I. (2016) · Ergonomics · doi:10.1080/00140139.2015.1079335 · Cited by 96
Metadata
- Authors
- Schepers, H. M., Roetenberg, D., & Veltink, P. H.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2009-12-17
- Volume
- 48
- Issue
- 1
- Pages
- 27-37
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2130215410
- Cited by
- 110
- References
- 1
- FWCI
- 22.61
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ambulatory human motion tracking by fusion of inertial and magnetic sensing with adaptive actuation. https://app.cochat.ai/papers/10.1007/s11517-009-0562-9
- The paper
- Schepers, H. M., Roetenberg, D., & Veltink, P. H. (2010). Ambulatory human motion tracking by fusion of inertial and magnetic sensing with adaptive actuation. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-009-0562-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.