Microelectrode arrays (MEAs) are designed to monitor and/or stimulate extracellularly neuronal activity. However, the biomechanical and structural mismatch between current MEAs and neural tissues remains a challenge for neural interfaces. This article describes a material strategy to prepare neural electrodes with improved mechanical compliance that relies on thin metal film electrodes embedded in polymeric substrates. The electrode impedance of micro-electrodes on polymer is comparable to that of MEA on glass substrates. Furthermore, MEAs on plastic can be flexed and rolled offering improved structural interface with brain and nerves in vivo. MEAs on elastomer can be stretched reversibly and provide in vitro unique platforms to simultaneously investigate the electrophysiological of neural cells and tissues to mechanical stimulation. Adding mechanical compliance to MEAs is a promising vehicle for robust and reliable neural interfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Cells Feel and Respond to the Stiffness of Their Substrate
Discher, D. E., Janmey, P., & Wang, Y.-L. (2005) · Science · doi:10.1126/science.1116995 · Cited by 6,382
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Stretchable gold conductors on elastomeric substrates
Lacour, S. P., Wagner, S., Huang, Z., & Suo, Z. (2003) · Applied Physics Letters · doi:10.1063/1.1565683 · Cited by 885
Self-citationCochlear implants: A remarkable past and a brilliant future
Wilson, B. S., & Dorman, M. F. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.005 · Cited by 868
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 2×
“Dense arrays of up to 256 electrodes are used in vitro to monitor/stimulate individual neurons or acute tissue slices [14, 27] and in vivo to treat or repair damaged brain tissues or peripheral nerves [16, 31].”
BackgroundMechanics of rollable and foldable film-on-foil electronics
Suo, Z., Ma, E. Y., Gleskova, H., & Wagner, S. (1999) · Applied Physics Letters · doi:10.1063/1.123478 · Cited by 711
Mechanisms of reversible stretchability of thin metal films on elastomeric substrates
Lacour, S. P., Chan, D., Wagner, S., Li, T., & Suo, Z. (2006) · Applied Physics Letters · doi:10.1063/1.2201874 · Cited by 413
Self-citationREHFELDT, F., ENGLER, A., ECKHARDT, A., AHMED, F., & DISCHER, D. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.007 · Cited by 405
Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants
Williams, J. C., Hippensteel, J. A., Dilgen, J., Shain, W., & Kipke, D. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/007 · Cited by 399
Cited by
Stretchable silicon nanoribbon electronics for skin prosthesis
Kim, J., Lee, M., Shim, H. J., Ghaffari, R., Cho, H. R., Son, D., Jung, Y. H., Soh, M., Choi, C., Jung, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms6747 · Cited by 1,435
Highly Skin‐Conformal Microhairy Sensor for Pulse Signal Amplification
Pang, C., Koo, J. H., Nguyen, A., Caves, J. M., Kim, M., Chortos, A., Kim, K., Wang, P. J., Tok, J. B. ‐., & Bao, Z. (2015) · Advanced Materials · doi:10.1002/adma.201403807 · Cited by 734
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
Flexible and Stretchable Capacitive Sensors with Different Microstructures
Qin, J., Yin, L., Hao, Y., Zhong, S., Zhang, D., Bi, K., Zhang, Y., Zhao, Y., & Dang, Z. (2021) · Advanced Materials · doi:10.1002/adma.202008267 · Cited by 616
Metadata
- Authors
- Lacour, S. P., Benmerah, S., Tarte, E., FitzGerald, J., Serra, J., McMahon, S., Fawcett, J., Graudejus, O., Yu, Z., & Morrison, B.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2010-06-10
- Volume
- 48
- Issue
- 10
- Pages
- 945-954
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2078231187
- Cited by
- 263
- References
- 42
- FWCI
- 5.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible and stretchable micro-electrodes for in vitro and in vivo neural interfaces. https://app.cochat.ai/papers/10.1007/s11517-010-0644-8
- The paper
- Lacour, S. P., Benmerah, S., Tarte, E., FitzGerald, J., Serra, J., McMahon, S., Fawcett, J., Graudejus, O., Yu, Z., & Morrison, B. (2010). Flexible and stretchable micro-electrodes for in vitro and in vivo neural interfaces. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-010-0644-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.