Detecting freezing of gait with a tri-axial accelerometer in Parkinson’s disease patients

Open access
Ahlrichs, Claas, Samà, Albert, Lawo, Michael, Cabestany, Joan, Rodríguez-Martín, Daniel, Pérez-López, Carlos, Sweeney, Dean, Quinlan, Leo R., Laighin, Gearòid Ò, Counihan, Timothy, Browne, Patrick, Hadas, Lewy, Vainstein, Gabriel, Costa, Alberto, Annicchiarico, Roberta, Alcaine, Sheila, Mestre, Berta, Quispe, Paola, Bayes, Àngels, Rodríguez-Molinero, Alejandro · 2016 · Medical & Biological Engineering & Computing

The DOI matches its Crossref record; 34 of the 36 references it cites were found in a registry or an index.

Abstract

Freezing of gait (FOG) is a common motor symptom of Parkinson's disease (PD), which presents itself as an inability to initiate or continue gait. This paper presents a method to monitor FOG episodes based only on acceleration measurements obtained from a waist-worn device. Three approximations of this method are tested. Initially, FOG is directly detected by a support vector machine (SVM). Then, classifier's outputs are aggregated over time to determine a confidence value, which is used for the final classification of freezing (i.e., second and third approach). All variations are trained with signals of 15 patients and evaluated with signals from another 5 patients. Using a linear SVM kernel, the third approach provides 98.7% accuracy and a geometric mean of 96.1%. Moreover, it is investigated whether frequency features are enough to reliably detect FOG. Results show that these features allow the method to detect FOG with accuracies above 90% and that frequency features enable a reliable monitoring of FOG by using simply a waist sensor.

Overview

Integrity signals

Registry

Crossref · 10.1007/s11517-015-1395-3

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 140

Metadata

Authors
Ahlrichs, C., Samà, A., Lawo, M., Cabestany, J., Rodríguez-Martín, D., Pérez-López, C., Sweeney, D., Quinlan, L. R., Laighin, G. Ò., Counihan, T., Browne, P., Hadas, L., Vainstein, G., Costa, A., Annicchiarico, R., Alcaine, S., Mestre, B., Quispe, P., Bayes, À., & Rodríguez-Molinero, A.
Affiliations
  • Universitat Politècnica de Catalunya (ES)
  • University of Bremen (DE)
  • Ollscoil na Gaillimhe – University of Galway (IE)
  • Maccabi Healthcare Services (IL)
  • University Niccolò Cusano (IT)
  • Fondazione Santa Lucia (IT)
Corresponding author
Ahlrichs, Claas
Venue
Medical & Biological Engineering & Computing
Published
2015-10-01
Volume
54
Issue
1
Pages
223-233
ISSN
  • 0140-0118 (ISSN-L)
  • 1741-0444
OpenAlex
W2177319998
Cited by
128
References
36
Citations by year
2026: 1 · 2025: 8 · 2024: 10 · 2023: 13 · 2022: 16 · 2021: 17 · 2020: 19 · 2019: 15 · 2018: 7 · 2017: 15 · 2016: 6 · 2015: 1
FWCI
25.43
Type
journal article
Language
en
Open access
Licence
  • cc-by-nc-nd
  • www.springer.com/tdm (tdm)
Locations
  • Medical & Biological Engineering & Computing (publishedVersion)
  • PubMed (publishedVersion)
  • LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (publishedVersion, cc-by-nc-nd)
  • RECERCAT (Consorci de Serveis Universitaris de Catalunya) (publishedVersion, other-oa)
  • ARAN (University of Galway Research Repository) (Ollscoil na Gaillimhe – University of Galway) (acceptedVersion, cc-by-nc-nd)
  • Arrow@dit (Dublin Institute of Technology) (submittedVersion)
  • ARAN (University of Galway Research Repository) (Ollscoil na Gaillimhe – University of Galway) (submittedVersion, cc-by-nc-nd)
  • ARAN (University of Galway Research Repository) (Ollscoil na Gaillimhe – University of Galway) (submittedVersion, cc-by-nc)
  • UPCommons institutional repository (Universitat Politècnica de Catalunya) (submittedVersion, cc-by-nc-nd)
  • Research Repository UCD (University College Dublin) (cc-by-nc)
Topics
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
Keywords
freezing of gait, Parkinson's disease, triaxial accelerometer, gait monitoring, support vector machine, frequency characteristics, wearable sensing
MeSH terms
Machine Learning, Gait, Humans, Parkinson Disease, Support Vector Machine, Accelerometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.