Detecting freezing of gait with a tri-axial accelerometer in Parkinson’s disease patients
Open accessThe DOI matches its Crossref record; 34 of the 36 references it cites were found in a registry or an index.
Abstract
Freezing of gait (FOG) is a common motor symptom of Parkinson's disease (PD), which presents itself as an inability to initiate or continue gait. This paper presents a method to monitor FOG episodes based only on acceleration measurements obtained from a waist-worn device. Three approximations of this method are tested. Initially, FOG is directly detected by a support vector machine (SVM). Then, classifier's outputs are aggregated over time to determine a confidence value, which is used for the final classification of freezing (i.e., second and third approach). All variations are trained with signals of 15 patients and evaluated with signals from another 5 patients. Using a linear SVM kernel, the third approach provides 98.7% accuracy and a geometric mean of 96.1%. Moreover, it is investigated whether frequency features are enough to reliably detect FOG. Results show that these features allow the method to detect FOG with accuracies above 90% and that frequency features enable a reliable monitoring of FOG by using simply a waist sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While normal gait steps have a main frequency from 0.5 to 3 Hz (determined with sensors placed on the ankles), FOG events present a main frequency in the range from 6 to 8 Hz [14,15,16].”
From Deep Learning Approaches for Detecting Freezing of Gait in Parkinson’s Disease Patients through On-Body Acceleration Sensors (2020) · cites this paper as [15]
In the citing paper
“While normal gait steps have a main frequency from 0.5 to 3 Hz (determined with sensors placed on the ankles), FOG events present a main frequency in the range from 6 to 8 Hz [14,15,16].”
From Deep Learning Approaches for Detecting Freezing of Gait in Parkinson’s Disease Patients through On-Body Acceleration Sensors (2020) · cites this paper as [15]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Support Vector Machines and Other Kernel-based Learning Methods
Cristianini, N., & Shawe-Taylor, J. (2000) · doi:10.1017/cbo9780511801389 · Cited by 13,855
Parkinsonism: onset, progression, and mortality
Hoehn, M. M., & Yahr, M. D. (1967) · Neurology · doi:10.1212/wnl.17.5.427 · Cited by 12,107 · cited 1×
“Clinical fluctuations were present in all patients as well as Hoehn and Yahr stage [13] above two (moderate–severe phase of PD).”
BackgroundHughes, A. J., Daniel, S. E., Kilford, L., & Lees, A. J. (1992) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.55.3.181 · Cited by 10,378
Parkinson's disease: clinical features and diagnosis
Jankovic, J. (2008) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2007.131045 · Cited by 5,720
Dauer, W., & Przedborski, S. (2003) · Neuron · doi:10.1016/s0896-6273(03)00568-3 · Cited by 5,469
Higgins, S. M. F., Macken, A. P., Cullen, W., Saunders, J., Dunne, C. P., & O’Gorman, C. S. (2013) · PubMed · doi:10.34961/9953 · Cited by 4,808
Overdependence on degraded gist memory in Alzheimer's disease.
Gallo, D. A., Shahid, K. R., Olson, M. A., Solomon, T. M., Schacter, D. L., & Budson, A. E. (2006) · Neuropsychology · doi:10.1037/0894-4105.20.6.625 · Cited by 4,732
Non-motor symptoms of Parkinson's disease: dopaminergic pathophysiology and treatment
Chaudhuri, K. R., & Schapira, A. H. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(09)70068-7 · Cited by 1,738
Parkinson, J. (2002) · The Journal of Neuropsychiatry and Clinical Neurosciences · doi:10.1176/jnp.14.2.223 · Cited by 1,628
Bloem, B. R., Hausdorff, J. M., Visser, J. E., & Giladi, N. (2004) · Movement Disorders · doi:10.1002/mds.20115 · Cited by 1,297
Cited by
Halilaj, E., Rajagopal, A., Fiterau, M., Hicks, J. L., Hastie, T. J., & Delp, S. L. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.09.009 · Cited by 460
Application of artificial intelligence in wearable devices: Opportunities and challenges
Nahavandi, D., Alizadehsani, R., Khosravi, A., & Acharya, U. R. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106541 · Cited by 372
Recent Advancements in Emerging Technologies for Healthcare Management Systems: A Survey
Junaid, S. B., Imam, A. A., Balogun, A. O., De Silva, L. C., Surakat, Y. A., Kumar, G., Abdulkarim, M., Shuaibu, A. N., Garba, A., Sahalu, Y., et al. (2022) · Healthcare · doi:10.3390/healthcare10101940 · Cited by 353
Rodríguez-Martín, D., Samà, A., Pérez-López, C., Català, A., Moreno Arostegui, J. M., Cabestany, J., Bayés, À., Alcaine, S., Mestre, B., Prats, A., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0171764 · Cited by 237
Self-citationMachine Learning‐Enabled Smart Sensor Systems
Ha, N., Xu, K., Ren, G., Mitchell, A., & Ou, J. Z. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000063 · Cited by 207
Wearable-Sensor-Based Detection and Prediction of Freezing of Gait in Parkinson’s Disease: A Review
Pardoel, S., Kofman, J., Nantel, J., & Lemaire, E. D. (2019) · Sensors · doi:10.3390/s19235141 · Cited by 201
“Experimental procedures and underlying definitions, such as ignoring FOG shorter than 3 s [43] or calculating specificity with data from participants without FOG [64], also varied between studies.”
BackgroundMethodResultInfluentialArtificial intelligence for assisting diagnostics and assessment of Parkinson’s disease—A review
Belić, M., Bobić, V., Badža, M., Šolaja, N., Đurić-Jovičić, M., & Kostić, V. S. (2019) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2019.105442 · Cited by 194
Silva de Lima, A. L., Evers, L. J. W., Hahn, T., Bataille, L., Hamilton, J. L., Little, M. A., Okuma, Y., Bloem, B. R., & Faber, M. J. (2017) · Journal of Neurology · doi:10.1007/s00415-017-8424-0 · Cited by 191
Clinical and methodological challenges for assessing freezing of gait: Future perspectives
Mancini, M., Bloem, B. R., Horak, F. B., Lewis, S. J. G., Nieuwboer, A., & Nonnekes, J. (2019) · Movement Disorders · doi:10.1002/mds.27709 · Cited by 173
“Despite the higher sensitivity in detecting the occurrence of even shorter FOG episodes compared to the previous method (an accuracy above 90% was achieved), these approaches may require a higher computational cost (high amount of resources necessary to run the algorithm), requiring up to around a minute from the occu…”
ResultMachine Learning Approach to Support the Detection of Parkinson’s Disease in IMU-Based Gait Analysis
Trabassi, D., Serrao, M., Varrecchia, T., Ranavolo, A., Coppola, G., Icco, R. D., Tassorelli, C., & Castiglia, S. F. (2022) · Sensors · doi:10.3390/s22103700 · Cited by 166
A clinical view on the development of technology‐based tools in managing Parkinson's disease
Maetzler, W., Klucken, J., & Horne, M. (2016) · Movement Disorders · doi:10.1002/mds.26673 · Cited by 162
Detection and assessment of Parkinson's disease based on gait analysis: A survey
Guo, Y., Yang, J., Liu, Y., Chen, X., & Yang, G. (2022) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2022.916971 · Cited by 128
Sigcha, L., Costa, N., Pavón, I., Costa, S., Arezes, P., López, J. M., & De Arcas, G. (2020) · Sensors · doi:10.3390/s20071895 · Cited by 126
Suppa, A., Kita, A., Leodori, G., Zampogna, A., Nicolini, E., Lorenzi, P., Rao, R., & Irrera, F. (2017) · Frontiers in Neurology · doi:10.3389/fneur.2017.00406 · Cited by 110
Wearables for independent living in older adults: Gait and falls
Godfrey, A. (2017) · Maturitas · doi:10.1016/j.maturitas.2017.03.317 · Cited by 105
The Practicalities of Assessing Freezing of Gait
Barthel, C., Mallia, E., Debu, B. H. G., Bloem, B. R., & Ferraye, M. (2016) · Journal of Parkinson s Disease · doi:10.3233/jpd-160927 · Cited by 104
A Technological Review of Wearable Cueing Devices Addressing Freezing of Gait in Parkinson’s Disease
Sweeney, D., Quinlan, L. R., Browne, P., Richardson, M., Meskell, P., & ÓLaighin, G. (2019) · Sensors · doi:10.3390/s19061277 · Cited by 103
Self-citationLu, R., Xu, Y., Li, X., Fan, Y., Zeng, W., Tan, Y., Ren, K., Chen, W., & Cao, X. (2020) · Parkinson s Disease · doi:10.1155/2020/4693019 · Cited by 95
Iakovakis, D., Hadjidimitriou, S., Charisis, V., Bostantzopoulou, S., Katsarou, Z., & Hadjileontiadis, L. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-25999-0 · Cited by 92
Mazzetta, I., Zampogna, A., Suppa, A., Gumiero, A., Pessione, M., & Irrera, F. (2019) · Sensors · doi:10.3390/s19040948 · Cited by 90
Nguyen, H., Lebel, K., Bogard, S., Goubault, É., Boissy, P., & Duval, C. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2745418 · Cited by 88
Nguyen, H., Lebel, K., Boissy, P., Bogard, S., Goubault, É., & Duval, C. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0241-2 · Cited by 80
Samà, A., Rodríguez-Martín, D., Pérez-López, C., Català, A., Alcaine, S., Mestre, B., Prats, A., Crespo, M. C., & Bayés, À. (2018) · Pattern Recognition Letters · doi:10.1016/j.patrec.2017.05.009 · Cited by 76
Self-citationReches, T., Dagan, M., Herman, T., Gazit, E., Gouskova, N., Giladi, N., Manor, B. D., & Hausdorff, J. M. (2020) · Sensors · doi:10.3390/s20164474 · Cited by 73
Pardoel, S., Shalin, G., Nantel, J., Lemaire, E. D., & Kofman, J. (2021) · Sensors · doi:10.3390/s21062246 · Cited by 72
Pierleoni, P., Belli, A., Bazgir, O., Maurizi, L., Paniccia, M., & Palma, L. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2932584 · Cited by 69
Mikos, V., Heng, C.-H., Tay, A. E., Yen, S., Chia, N. S. Y., Koh, K. M. L., Tan, D. M. L., & Au, W. L. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2914253 · Cited by 63
Huang, T., Li, M., & Huang, J. (2023) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2023.1119956 · Cited by 58
Singh, B., CHASTIN, S. F. M., Miatke, A., Curtis, R., Dumuid, D., Brinsley, J., Ferguson, T., Szeto, K., Simpson, C., Eglitis, E., et al. (2024) · JMIR mhealth and uhealth · doi:10.2196/56972 · Cited by 56
Home monitoring of motor fluctuations in Parkinson’s disease patients
Borzì, L., Varrecchia, M., Olmo, G., Artusi, C. A., Fabbri, M., Rizzone, M. G., Romagnolo, A., Zibetti, M., & Lopiano, L. (2019) · Journal of Reliable Intelligent Environments · doi:10.1007/s40860-019-00086-x · Cited by 54
Filtjens, B., Ginis, P., Nieuwboer, A., Slaets, P., & Vanrumste, B. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-01025-3 · Cited by 52
Suzuki, M., Mitoma, H., & Yoneyama, M. (2017) · Parkinson s Disease · doi:10.1155/2017/6139716 · Cited by 50
A Non-Invasive Medical Device for Parkinson’s Patients with Episodes of Freezing of Gait
Punín, C., Barzallo, B., Clotet, R., Bermeo, A., Bravo, M., Bermeo, J. P., & Llumiguano, C. (2019) · Sensors · doi:10.3390/s19030737 · Cited by 49
de Souza, C. R., Miao, R., de Oliveira, J. Á., de Lima‐Pardini, A. C., de Campos, D. D. S. F., Silva‐Batista, C., Teixeira, L. A., Shokur, S., Bouri, M., & Coelho, D. B. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.832463 · Cited by 48
Trends in Graphene-Based E-Skin and Artificial Intelligence for Biomedical Applications—A Review
Mudhulu, S., Manjunatha, C., Balaji, S., Khosla, A., & Sekhar, P. K. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3294297 · Cited by 43
Wu, P., Cao, B., Liang, Z., & Wu, M. (2023) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2023.1191378 · Cited by 43
Selection of clinical features for pattern recognition applied to gait analysis
Altilio, R., Paoloni, M., & Panella, M. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1546-1 · Cited by 42
Pinto, C., Schuch, C. P., Balbinot, G. C., Salazar, A. P., Hennig, E. M., Kleiner, A. F. R., & Pagnussat, A. S. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0579-8 · Cited by 39
Nukala, B. T., Nakano, T., Rodriguez, A. I., Tsay, J., Lopez, J., Nguyen, T., Zupancic, S., & Lie, D. Y. C. (2016) · Biosensors · doi:10.3390/bios6040058 · Cited by 39
Chomiak, T., Xian, W., Pei, Z., & Hu, B. (2019) · Journal of Neural Transmission · doi:10.1007/s00702-019-02020-0 · Cited by 38
Deep Learning for Daily Monitoring of Parkinson’s Disease Outside the Clinic Using Wearable Sensors
Atri, R., Urban, K., Marebwa, B., Simuni, T., Tanner, C. M., Siderowf, A. D., Frasier, M. A., Haas, M., & Lancashire, L. (2022) · Sensors · doi:10.3390/s22186831 · Cited by 39
Artusi, C. A., Imbalzano, G., Sturchio, A., Pilotto, A., Montanaro, E., Padovani, A., Lopiano, L., Maetzler, W., & Espay, A. J. (2020) · Neurotherapeutics · doi:10.1007/s13311-020-00901-x · Cited by 37
Detection and prediction of freezing of gait with wearable sensors in Parkinson’s disease
Zhang, W., Sun, H., Huang, D., Zhang, Z., Li, J., Wu, C., Sun, Y., Gong, M., Wang, Z., Sun, C., et al. (2023) · Neurological Sciences · doi:10.1007/s10072-023-07017-y · Cited by 36
Habib, Z., Mughal, M. A., Khan, M. A., & Shabaz, M. (2023) · Alexandria Engineering Journal · doi:10.1016/j.aej.2023.11.075 · Cited by 36
Guo, C. C., Chiesa, P. A., de Moor, C., Fazeli, M. S., Schofield, T., Hofer, K., Belachew, S. M., & Scotland, A. (2022) · Journal of Medical Internet Research · doi:10.2196/37683 · Cited by 35
Detection of Freezing of Gait Using Unsupervised Convolutional Denoising Autoencoder
Noor, M. H. M., Nazir, A., Wahab, M. N. A., & Ling, J. O. Y. (2021) · IEEE Access · doi:10.1109/access.2021.3104975 · Cited by 33
Ashfaque Mostafa, T., Soltaninejad, S., McIsaac, T. L., & Cheng, I. (2021) · Sensors · doi:10.3390/s21196446 · Cited by 32
A fuzzy logic system for the home assessment of freezing of gait in subjects with Parkinsons disease
Pepa, L., Capecci, M., Andrenelli, E., Ciabattoni, L., Spalazzi, L., & Ceravolo, M. G. (2020) · Expert Systems with Applications · doi:10.1016/j.eswa.2020.113197 · Cited by 32
Pardoel, S., Nantel, J., Kofman, J., & Lemaire, E. D. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.831063 · Cited by 32
Bansal, S. K., Basumatary, B., Bansal, R., & Sahani, A. K. (2023) · MethodsX · doi:10.1016/j.mex.2023.102106 · Cited by 31
Zhang, W., Schwenk, M., Mellone, S., Paraschiv-Ionescu, A., Vereijken, B., Pijnappels, M. A. G. M., Mikolaizak, A. S., Boulton, E., Jonkman, N. H., Maier, A. B., et al. (2018) · Sensors · doi:10.3390/s18072032 · Cited by 31
Mikos, V., Heng, C.-H., Tay, A. E., Chia, N. S. Y., Koh, K. M. L., Tan, D. M. L., & Au, W. L. (2017) · International Conference on Machine Learning and Applications · doi:10.1109/icmla.2017.00-46 · Cited by 28
Zhang, Y., & Gu, D. (2019) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp-bmei48845.2019.8965723 · Cited by 27
Study of Machine and Deep Learning Classifications for IOT Enabled Healthcare Devices
Kumar, Y., Gupta, S., & Gupta, A. (2021) · International Conference on Technological Advancements and Innovations (ICTAI) · doi:10.1109/ictai53825.2021.9673437 · Cited by 27
Freezing of Gait Detection for Parkinson’s Disease Patients using Accelerometer Data: Case Study
Tăuţan, A.-M., Andrei, A.-G., & Ionescu, B. E. (2020) · E-Health and Bioengineering Conference (EHB) · doi:10.1109/ehb50910.2020.9280223 · Cited by 26
Huang, D., Wu, C., Wang, Y., Zhang, Z., Chen, C., Li, L., Zhang, W., Zhang, Z., Li, J., Guo, Y., et al. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105613 · Cited by 25
Abbasi, S., & Rezaee, K. (2024) · Brain and Behavior · doi:10.1002/brb3.70206 · Cited by 24
Video-Based Detection of Freezing of Gait in Daily Clinical Practice in Patients With Parkinsonism
Kondo, Y., Bando, K., Suzuki, I., Miyazaki, Y., Nishida, D., Hara, T., Kadone, H., & Suzuki, K. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3413055 · Cited by 24
Borzì, L., Fornara, S., Amato, F., Olmo, G., Artusi, C. A., & Lopiano, L. (2020) · Electronics · doi:10.3390/electronics9060919 · Cited by 24
Halder, A., Singh, R., Suri, A., & Joshi, D. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3090153 · Cited by 23
Li, B., Zhang, Y., Tang, L., Gao, C., & Gu, D. (2018) · IEEE Advanced Information Management, Communicates, Electronic and Automation Control Conference (IMCEC) · doi:10.1109/imcec.2018.8469471 · Cited by 23
Al-Adhaileh, M. H., Wadood, A., Aldhyani, T. H. H., Khan, S. H., Uddin, M. I., & Al-Nefaie, A. H. A. (2025) · Frontiers in Physiology · doi:10.3389/fphys.2025.1581699 · Cited by 23
Kwon, Y., Lee, Y.-K., Kilic‐Berkmen, G., Lim, H., Scorr, L., Jinnah, H. A., & Yeo, W. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900458 · Cited by 23
Detection of Freezing of Gait in People with Parkinson’s Disease using Smartphones
Borzì, L., Olmo, G., Artusi, C. A., & Lopiano, L. (2020) · IEEE Annual International Computer Software and Applications Conference (COMPSAC) · doi:10.1109/compsac48688.2020.0-186 · Cited by 22
Prado, A., Kwei, S. K., Vanegas‐Arroyave, N., & Agrawal, S. K. (2021) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2021.3091526 · Cited by 22
Understanding the Physiological Significance of Four Inertial Gait Features in Multiple Sclerosis
Dandu, S. R., Engelhard, M., Qureshi, A., Gong, J., Lach, J., Brandt-Pearce, M., & Goldman, M. D. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2773629 · Cited by 22
Yang, B., Li, Y., Wang, F., Au-Yeung, S. S. Y., Leung, M., Mak, K. Y., & Tao, X. (2022) · Wearable Technologies · doi:10.1017/wtc.2022.9 · Cited by 21
Machine Learning for Parkinson’s Disease and Related Disorders
Faouzi, J., Colliot, O., & Corvol, J. (2023) · Neuromethods · doi:10.1007/978-1-0716-3195-9_26 · Cited by 21
FoG-Finder: Real-time Freezing of Gait Detection and Treatment
Koltermann, K., Jung, W., Blackwell, G. G., Pinney, A., Chen, M., Cloud, L. J., Pretzer‐Aboff, I., & Zhou, G. (2023) · IEEE/ACM Conference on Connected Health: Applications, Systems and Engineering Technologies · doi:10.1145/3580252.3586980 · Cited by 20
Guo, R., Xie, Z., Zhang, C., & Qian, X. (2024) · IEEE Transactions on Image Processing · doi:10.1109/tip.2024.3416052 · Cited by 19
PdAssist: Objective and quantified symptom assessment of Parkinson's disease via smartphone
Chen, Y., Yang, X., Chen, B., Miao, C., & Yu, H. (2017) · IEEE International Conference on Bioinformatics and Biomedicine (BIBM) · doi:10.1109/bibm.2017.8217783 · Cited by 18
Aich, S., Sain, M., Park, J., Choi, K.-W., & Kim, H. (2017) · International Conference on Inventive Computing and Informatics (ICICI) · doi:10.1109/icici.2017.8365398 · Cited by 18
Zhuparris, A., de Goede, A. A., Yocarini, I. E., Kraaij, W., Groeneveld, G. J., & Doll, R. J. (2023) · Sensors · doi:10.3390/s23115243 · Cited by 18
Pardoel, S., Shalin, G., Nantel, J., Lemaire, E. D., & Kofman, J. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176607 · Cited by 17
Freezing of Gait Detection Using Gramian Angular Fields and Federated Learning from Wearable Sensors
Soumma, S. B., Alam, S., Rahman, R., Mahi, U. N., Mamun, A., Mostafavi, S. M., & Ghasemzadeh, H. G. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11254302 · Cited by 17
HulaMove: Using Commodity IMU for Waist Interaction
Xu, X., Li, J., Yuan, T., He, L., Liu, X., Yan, Y., Wang, Y., Shi, Y., Mankoff, J. C., & Dey, A. K. (2021) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3411764.3445182 · Cited by 17
Diep, C., O’Day, J. J., Kehnemouyi, Y. M., Burnett, G., & Bronte-Stewart, H. M. (2021) · Sensors · doi:10.3390/s21082661 · Cited by 16
Gait-Guard: Turn-aware Freezing of Gait Detection for Non-intrusive Intervention Systems
Koltermann, K., Clapham, J., Blackwell, G. G., Jung, W., Burnet, E. N., Gao, Y., Shao, H., Cloud, L. J., Pretzer‐Aboff, I., & Zhou, G. (2024) · IEEE/ACM Conference on Connected Health: Applications, Systems and Engineering Technologies · doi:10.1109/chase60773.2024.00016 · Cited by 15
Artificial Intelligence in Medical Metaverse: Applications, Challenges, and Future Prospects
Yang, J., Chen, B., Li, R., Huang, B.-Q., Zhao, M.-H., Liu, P., Zhang, J., & Ye, Z. (2024) · Current Medical Science · doi:10.1007/s11596-024-2960-5 · Cited by 15
Wearable computing of Freezing of Gait in Parkinson's disease: A survey
Sun, M., Watson, A., & Zhou, G. (2020) · Smart Health · doi:10.1016/j.smhl.2020.100143 · Cited by 13
Delgado-Terán, J. D., Hilbrants, K., Mahmutović, D., de Lima, A. L. S., Wezel, R. J. A. V., & Heida, T. (2025) · Sensors · doi:10.3390/s25061895 · Cited by 12
Al-Nefaie, A. H. A., Aldhyani, T. H. H., Farhah, N. S., & Koundal, D. (2024) · Frontiers in Medicine · doi:10.3389/fmed.2024.1418684 · Cited by 9
Activity and Emotion Recognition for Elderly Health Monitoring
Benaissa, B., Köppen, M., & Yoshida, K. (2018) · International Journal of Affective Engineering · doi:10.5057/ijae.ijae-d-17-00020 · Cited by 8
Prado, A., Kwei, K., Vanegas‐Arroyave, N., & Agrawal, S. K. (2020) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob49111.2020.9224357 · Cited by 8
Elziaat, H., El-Bendary, N., & Moawad, R. (2020) · International Conference on Innovative Trends in Computer Engineering (ITCE) · doi:10.1109/itce48509.2020.9047813 · Cited by 7
FPGA-Based Realtime Detection of Freezing of Gait of Parkinson Patients
Langer, P., Esfahani, A. H., Dyka, Z., & Langendörfer, P. (2022) · Lecture notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-030-95593-9_9 · Cited by 7
A Survey on Freezing of Gait Detection and Prediction in Parkinson’s Disease
Martínez-Villaseñor, L., Ponce-Espinosa, H., & Miralles‐Pechuán, L. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-60884-2_13 · Cited by 6
Mikos, V., Heng, C.-H., Tay, A. E., Yen, S., Chia, N. S. Y., Koh, K. M. L., Tan, D. M. L., & Au, W. L. (2018) · IEEE Asian Solid-State Circuits Conference (A-SSCC) · doi:10.1109/asscc.2018.8579283 · Cited by 6
New Gait Representation Maps for Enhanced Recognition in Clinical Gait Analysis
Samee, N. M. A., Al‐masni, M. A., Marzban, E. N., Al-Shamiri, A. K., Al–antari, M. A., Alabdulhafith, M. I., Mahmoud, N. F., & Kadah, Y. M. (2025) · Bioengineering · doi:10.3390/bioengineering12101130 · Cited by 6
Bibbo, D., Marchis, C. D., Schmid, M., & Ranaldi, S. (2023) · Physiological Measurement · doi:10.1088/1361-6579/ad133b · Cited by 5
Cueing of Parkinson's Disease Patients by Standard Smart Devices and Deep Learning Approach
Satala, P., Butka, P., Samaiev, A., & Levicka, P. (2023) · Acta Polytechnica Hungarica · doi:10.12700/aph.20.2.2023.2.9 · Cited by 5
Parkinson’s Disease Detection Through Deep Learning Model
Bhakar, S., & Verma, S. S. (2022) · Lecture notes in networks and systems · doi:10.1007/978-981-19-5221-0_10 · Cited by 5
Sigcha, L. (2021) · UPM Digital Archive (Technical University of Madrid) · doi:10.20868/upm.thesis.68904 · Cited by 4
Huang, X., Latt, M. D., Khushi, M., Pelicioni, P. H. S., Brodie, M. A. D., Lord, S. R., Loy, C. T., & Poon, S. K.-S. (2021) · Hawaii International Conference on System Sciences (HICSS) · doi:10.24251/hicss.2021.413 · Cited by 4
Deep feature learning for FoG episodes prediction In patients with PD
Elziaat, H., El-Bendary, N., & Mowad, R. (2020) · Future Computing and Informatics Journal · doi:10.54623/fue.fcij.5.2.2 · Cited by 4
Aghanavesi, S., & Westin, J. (2016) · Lecture notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-319-51234-1_8 · Cited by 4
Olivas-Padilla, B. E. (2023) · theses.fr (ABES) · doi:10.70675/f1e01236z3fa4z461cza1bdz29f97f3bd7e7 · Cited by 4
USOS DE LOS ACELERÓMETROS EN FISIOTERAPIA: UNA REVISIÓN DE LA LITERATURA
Mantilla, J. A. (2017) · Revista Iberoamericana de Ciencias de la Actividad Física y el Deporte · doi:10.24310/riccafd.2017.v6i2.3781 · Cited by 4
Kim, H., Park, C., & You, J. H. (2022) · Neurorehabilitation · doi:10.3233/nre-210331 · Cited by 4
Artificial Hydrocarbon Networks for Freezing of Gait Detection in Parkinso’s Disease
Martínez-Villaseñor, L., Ponce-Espinosa, H., & Núñez-Martínez, J. (2020) · International Conference on Mechatronics, Electronics and Automotive Engineering (ICMEAE) · doi:10.1109/icmeae51770.2020.00008 · Cited by 3
Metadata
- Authors
- Ahlrichs, C., Samà, A., Lawo, M., Cabestany, J., Rodríguez-Martín, D., Pérez-López, C., Sweeney, D., Quinlan, L. R., Laighin, G. Ò., Counihan, T., Browne, P., Hadas, L., Vainstein, G., Costa, A., Annicchiarico, R., Alcaine, S., Mestre, B., Quispe, P., Bayes, À., & Rodríguez-Molinero, A.
- Affiliations
- Universitat Politècnica de Catalunya (ES)
- University of Bremen (DE)
- Ollscoil na Gaillimhe – University of Galway (IE)
- Maccabi Healthcare Services (IL)
- University Niccolò Cusano (IT)
- Fondazione Santa Lucia (IT)
- Corresponding author
- Ahlrichs, Claas
- ORCID
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2015-10-01
- Volume
- 54
- Issue
- 1
- Pages
- 223-233
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2177319998
- Cited by
- 128
- References
- 36
- Citations by year
- 2026: 1 · 2025: 8 · 2024: 10 · 2023: 13 · 2022: 16 · 2021: 17 · 2020: 19 · 2019: 15 · 2018: 7 · 2017: 15 · 2016: 6 · 2015: 1
- FWCI
- 25.43
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by-nc-nd
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (publishedVersion, cc-by-nc-nd)
- RECERCAT (Consorci de Serveis Universitaris de Catalunya) (publishedVersion, other-oa)
- ARAN (University of Galway Research Repository) (Ollscoil na Gaillimhe – University of Galway) (acceptedVersion, cc-by-nc-nd)
- Arrow@dit (Dublin Institute of Technology) (submittedVersion)
- ARAN (University of Galway Research Repository) (Ollscoil na Gaillimhe – University of Galway) (submittedVersion, cc-by-nc-nd)
- ARAN (University of Galway Research Repository) (Ollscoil na Gaillimhe – University of Galway) (submittedVersion, cc-by-nc)
- UPCommons institutional repository (Universitat Politècnica de Catalunya) (submittedVersion, cc-by-nc-nd)
- Research Repository UCD (University College Dublin) (cc-by-nc)
- Topics
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Keywords
- freezing of gait, Parkinson's disease, triaxial accelerometer, gait monitoring, support vector machine, frequency characteristics, wearable sensing
- MeSH terms
- Machine Learning, Gait, Humans, Parkinson Disease, Support Vector Machine, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.