A review of methods for the signal quality assessment to improve reliability of heart rate and blood pressures derived parameters

Gambarotta, Nicolò, Aletti, Federico, Baselli, Giuseppe, Ferrario, Manuela·2016·Medical & Biological Engineering & Computing

Abstract

The assessment of signal quality has been a research topic since the late 1970s, as it is mainly related to the problem of false alarms in bedside monitors in the intensive care unit (ICU), the incidence of which can be as high as 90 %, leading to alarm fatigue and a drop in the overall level of nurses and clinicians attention. The development of efficient algorithms for the quality control of long diagnostic electrocardiographic (ECG) recordings, both single- and multi-lead, and of the arterial blood pressure (ABP) signal is therefore essential for the enhancement of care quality. The ECG signal is often corrupted by noise, which can be within the frequency band of interest and can manifest similar morphologies as the ECG itself. Similarly to ECG, also the ABP signal is often corrupted by non-Gaussian, nonlinear and non-stationary noise and artifacts, especially in ICU recordings. Moreover, the reliability of several important parameters derived from ABP such as systolic blood pressure or pulse pressure is strongly affected by the quality of the ABP waveform. In this work, several up-to-date algorithms for the quality scoring of a single- or multi-lead ECG recording, based on time-domain approaches, frequency-domain approaches or a combination of the two will be reviewed, as well as methods for the quality assessment of ABP. Additionally, algorithms exploiting the relationship between ECG and pulsatile signals, such as ABP and photoplethysmographic recordings, for the reduction in the false alarm rate will be presented. Finally, some considerations will be drawn taking into account the large heterogeneity of clinical settings, applications and goals that the reviewed algorithms have to deal with.

Integrity signals

Registry

Crossref · 10.1007/s11517-016-1453-5

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Gambarotta, N., Aletti, F., Baselli, G., & Ferrario, M.
Affiliations
Politecnico di Milano (IT)
Corresponding author
Ferrario, Manuela
Venue
Medical & Biological Engineering & Computing
Published
2016-02-23
Volume
54
Issue
7
Pages
1025-1035
ISSN
  • 0140-0118 (ISSN-L)
  • 1741-0444
OpenAlex
W2282109974
Cited by
45
References
39
Citations by year
2025: 2 · 2024: 4 · 2023: 3 · 2022: 3 · 2021: 7 · 2020: 2 · 2019: 7 · 2018: 11 · 2017: 4 · 2016: 2
FWCI
1.41
Type
journal article
Language
en
Open access
closed
Locations
  • Medical & Biological Engineering & Computing (publishedVersion)
  • PubMed (publishedVersion)
  • Virtual Community of Pathological Anatomy (University of Castilla La Mancha) (submittedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
signal quality assessment, false alarm reduction, alarm fatigue, intensive care monitoring, ECG artifacts, photoplethysmography, pulse pressure, systolic blood pressure, non-stationary noise
MeSH terms
Algorithms, Blood Pressure, Blood Pressure Determination, Electrocardiography, Heart Rate, Humans, Quality Control, Signal Processing, Computer-Assisted, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review