Can one detect atrial fibrillation using a wrist-type photoplethysmographic device?
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This study aims at evaluating the potential of a wrist-type photoplethysmographic (PPG) device to discriminate between atrial fibrillation (AF) and other types of rhythm. Data from 17 patients undergoing catheter ablation of various arrhythmias were processed. ECGs were used as ground truth and annotated for the following types of rhythm: sinus rhythm (SR), AF, and ventricular arrhythmias (VA). A total of 381/1370/415 10-s epochs were obtained for the three categories, respectively. After pre-processing and removal of segments corresponding to motion artifacts, two different types of feature were derived from the PPG signals: the interbeat interval-based features and the wave-based features, consisting of complexity/organization measures that were computed either from the PPG waveform itself or from its power spectral density. Decision trees were used to assess the discriminative capacity of the proposed features. Three classification schemes were investigated: AF against SR, AF against VA, and AF against (SR&VA). The best results were achieved by combining all features. Accuracies of 98.1/95.9/95.0 %, specificities of 92.4/88.7/92.8 %, and sensitivities of 99.7/98.1/96.2 % were obtained for the three aforementioned classification schemes, respectively. Graphical Abstract Atrial fibrillation detection using PPG signals Atrial fibrillation detection using PPG signals
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McManus, D. D., Lee, J., Maitas, O., Esa, N., Pidikiti, R., Carlucci, A., Harrington, J., Mick, E., & Chon, K. H. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2012.12.001 · Cited by 253
Detection of atrial fibrillation using an earlobe photoplethysmographic sensor
Conroy, T., Guzman, J. H., Hall, B., Tsouri, G., & Couderc, J.-P. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa8830 · Cited by 50
Naraharisetti, K. V. P., & Bawa, M. (2011) · 2011 IEEE INTERNATIONAL CONFERENCE ON ELECTRO/INFORMATION TECHNOLOGY · doi:10.1109/eit.2011.5978571 · Cited by 35
Cited by
Photoplethysmography based atrial fibrillation detection: a review
Pereira, T., Tran, N., Gadhoumi, K., Pelter, M. M., Do, D. H., Lee, R. J., Colorado, R., Meisel, K., & Hu, X. (2020) · npj Digital Medicine · doi:10.1038/s41746-019-0207-9 · Cited by 300
“The most common approach to deal with this issue is to simply discard the corrupted segments and use only the clean parts of PPG signals.(49,50,58,60,64,74) Some of the works followed a two-step approach: first, to identify motion artifacts by using accelerometer data, or by performing PPG signal quality assessment; a…”
MethodHuang, J.-D., Wang, J., Ramsey, E., Leavey, G., Chico, T. J. A., & Condell, J. (2022) · Sensors · doi:10.3390/s22208002 · Cited by 175
“…two research works have been published that used deep SNNs to identify arrhythmias in a power-saving way [66, Further, numerous studies have been developed to address detection and predictive models for AF disorders due to their impact and clinical significance [20,21,25,26,32,33,36,41 – 43, 67].”
BackgroundPhotoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
“Tree based algorithms, utilising the PPG, have been applied in numerous tasks such as estimating blood pressure [165], [188], blood glucose [174], oxygen saturation levels [177], stress levels [181], and atrial fibrillation detection [162].”
MethodDetection of atrial fibrillation using a wrist-worn device
Sološenko, A., Petrėnas, A., Paliakaitė, B., Sörnmo, L., & Marozas, V. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab029c · Cited by 45
Paliakaitė, B., Petrėnas, A., Sološenko, A., & Marozas, V. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102421 · Cited by 24
Eerikäinen, L. M., Bonomi, A. G., Dekker, L. R. C., Vullings, R., & Aarts, R. M. (2020) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2020.03.001 · Cited by 24
“IBI features have been combined with this additional information using machine learning.(20,28,31) Along with traditional machine learning methods, deep learning approaches have been proposed for AF detection from wrist-worn PPG.”
BackgroundMethod
Metadata
- Authors
- Fallet, S., Lemay, M., Renevey, P., Leupi, C., Pruvot, E., & Vesin, J.-M.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2018-09-15
- Volume
- 57
- Issue
- 2
- Pages
- 477-487
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2890322328
- Cited by
- 58
- References
- 3
- FWCI
- 2.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.