Detection of atrial fibrillation using an earlobe photoplethysmographic sensor
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Atrial fibrillation (AF) is the most common cardiac arrhythmia in the world, associated with increased risk of thromboembolic events and an increased mortality rate. In addition, a significant portion of AF patients are asymptomatic. Current AF diagnostic methods, often including a body surface electrocardiogram or implantable loop recorder, are both expensive and invasive and offer limited access within the general community. OBJECTIVE: We tested the feasibility of the detection of AF using a photoplethysmographic signal acquired from an inexpensive, non-invasive earlobe photoplethysmographic sensor. This technology can be implemented into wearable devices and would enable continuous cardiac monitoring capabilities, greatly improving the rate of asymptomatic AF detection. APPROACH: We conducted a clinical study of patients going through electrical cardioversion for AF treatment. Photoplethysmographic recordings were taken from these AF patients before and after their cardioversion procedure, along with recordings from a healthy control group. Using these recordings, cardiac beats were identified and the inter-systolic interval was calculated. The inter-systolic interval was used to calculate four parameters to quantify the heart rate variability indicative of AF. Receiver operating characteristic curves were used to calculate discriminant thresholds between the AF and non-AF cohorts. MAIN RESULTS: The parameter with the greatest discriminant capability resulted in a sensitivity and specificity of 90.9%. These results are comparable to expensive ECG-based and invasive implantable loop recorder AF detection methods. SIGNIFICANCE: These results demonstrate that using a non-invasive earlobe photoplethysmographic signal is a viable and inexpensive alternative to ECG-based AF detection methods, and an alternative that could be invaluable in detecting subclinical AF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Using a light source and a photodetector, the pulse waveform can be measured by detecting changes in the light intensity, which reflects the tissue blood volume of a skin surface such as the fingertip, earlobe, or face (Conroy 2017, McManus 2013).”
From 2021 ISHNE/HRS/EHRA/APHRS Expert Collaborative Statement on mHealth in Arrhythmia Management: Digital Medical Tools for Heart Rhythm Professionals: From the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia-Pacific Heart Rhythm Society (2021) · cites this paper as Conroy 2017
In the citing paper
“Photoplethysmography is an optical technique that can be used to detect AF by measuring and analyzing a peripheral pulse waveform.”
From 2021 ISHNE/HRS/EHRA/APHRS Expert Collaborative Statement on mHealth in Arrhythmia Management: Digital Medical Tools for Heart Rhythm Professionals: From the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia-Pacific Heart Rhythm Society (2021) · cites this paper as Conroy 2017
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An introduction to ROC analysis
Fawcett, T. (2006) · Pattern Recognition Letters · doi:10.1016/j.patrec.2005.10.010 · Cited by 21,879
Atrial fibrillation as an independent risk factor for stroke: the Framingham study
Wolf, P. A., Abbott, R. D., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.8.983 · Cited by 7,388
Impact of Atrial Fibrillation on the Risk of Death: The Framingham Heart Study
Benjamin, E. J., Wolf, P. A., D’Agostino, R. B., Silbershatz, H., Kannel, W. B., & Levy, D. (1998) · Circulation · doi:10.1161/01.cir.98.10.946 · Cited by 4,575
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Feinberg, W. M., Blackshear, J. L., Laupacis, A., Kronmal, R., & Hart, R. G. (1995) · Archives of Internal Medicine · doi:10.1001/archinte.1995.00430050045005 · Cited by 2,519
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
Prevalence, incidence and lifetime risk of atrial fibrillation: the Rotterdam study
Heeringa, J., van der Kuip, D. A. M., Hofman, A., Kors, J. A., van Herpen, G., Stricker, B. H. C., Stijnen, T., Lip, G. Y. H., & Witteman, J. C. M. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi825 · Cited by 1,939 · cited 1×
“[1,2] AF is associated with diminished quality of life, congestive heart failure, devastating thromboembolic events, [3] and an increased mortality rate.”
BackgroundOn the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206 · cited 1×
“[16] In addition to this second peak, the raw PPG signal is usually affected by various noise components including baseline wandering and transient noise due to sensor movement.”
BackgroundSingh, S., Zoble, R. G., Yellen, L., Brodsky, M. A., Feld, G. K., Berk, M., & Billing, C. B. (2000) · Circulation · doi:10.1161/01.cir.102.19.2385 · Cited by 433
New method for assessing cardiac parasympathetic activity using 24 hour electrocardiograms.
Ewing, D. J., Neilson, J. M., & Travis, P. (1984) · Heart · doi:10.1136/hrt.52.4.396 · Cited by 403
Cited by
Photoplethysmography based atrial fibrillation detection: a review
Pereira, T., Tran, N., Gadhoumi, K., Pelter, M. M., Do, D. H., Lee, R. J., Colorado, R., Meisel, K., & Hu, X. (2020) · npj Digital Medicine · doi:10.1038/s41746-019-0207-9 · Cited by 300
Mejía‐Mejía, E., May, J. M., Torres, R., & Kyriacou, P. A. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab998c · Cited by 183
Dang, H., Sun, M., Zhang, G., Qi, X., Zhou, X., & Chang, Q. (2019) · IEEE Access · doi:10.1109/access.2019.2918792 · Cited by 113
Kwon, S., Hong, J., Choi, E.-K., Lee, E., Hostallero, D. E., Kang, W. J., Lee, B., Jeong, E.-R., Koo, B.-K., Oh, S., et al. (2019) · JMIR mHealth and uHealth · doi:10.2196/12770 · Cited by 90
Bonomi, A. G., Schipper, F., Eerikäinen, L. M., Margarito, J., van Dinther, R., Muesch, G., de Morree, H. M., Aarts, R. M., Babaeizadeh, S., McManus, D. D., et al. (2018) · Journal of the American Heart Association · doi:10.1161/jaha.118.009351 · Cited by 89
Metadata
- Authors
- Conroy, T., Guzman, J. H., Hall, B., Tsouri, G., & Couderc, J.-P.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2017-09-26
- Volume
- 38
- Issue
- 10
- Pages
- 1906-1918
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2749369527
- Cited by
- 50
- References
- 35
- FWCI
- 2.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of atrial fibrillation using an earlobe photoplethysmographic sensor. https://app.cochat.ai/papers/10.1088/1361-6579/aa8830
- The paper
- Conroy, T., Guzman, J. H., Hall, B., Tsouri, G., & Couderc, J.-P. (2017). Detection of atrial fibrillation using an earlobe photoplethysmographic sensor. Physiological Measurement. https://doi.org/10.1088/1361-6579/aa8830
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.