In vivo static and dynamic lengthening measurements of the posterior cruciate ligament at high knee flexion angles
Open accessAbstract
Purpose Rehabilitation is an important aspect of both non-operative and operative treatments of knee ligament tear. Posterior cruciate ligament (PCL) non-operative treatment consists of a step-by-step rehabilitation protocol and is well described. It goes from rest (phase I) to strengthening exercises (phase IV). More specific and high-intensity exercises such as cutting, sidestepping or jumps are, however, not described in detail, as no in vivo data exist to tell how these exercises constrain the ligaments and whether they have the same effect on all of them, in particular regarding lengthening. The goal of this study was to measure the ligament lengthening in static knee flexion based on 3D reconstructions from magnetic resonance imaging (MRI) and from motion capture and ligament simulation during dynamic exercises.Methods The knee of nine volunteers was first imaged in a closed-bore MRI scanner at various static knee flexion angles (up to 110°), and the corresponding lengthening of the PCL and the other major knee ligaments was measured. Then, the volunteers underwent motion capture of the knee where dynamic exercises (sitting, jumping, sidestepping, etc.) were recorded. For each exercise, knee ligament elongation was simulated and evaluated.Results According to the MRI scans, maximal lengthening occurred at 110° of flexion in the anterior cruciate ligament and 90° of flexion in the PCL. Daily living movements such as sitting were predicted to elongate the cruciate ligaments, whereas they shortened the collateral ligaments. More active movements such as jumping put the most constrain to cruciate ligaments.Conclusion This study provides interesting insights into a tailored postoperative regimen. In particular, knowing the knee ligament lengthening during dynamic exercises can help better define the last stages of the rehabilitation protocol, and hence provide a safe return to play.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Others also characterize knee joint kinematic function in three-dimensional (3D) based on MR images under weight-bearing conditions or measure length of ligament using MR images combined with motion capture system, but no further biomechanical analysis was performed [8, 9].”
Citations
Cites
Wu, G., Siegler, S., Allard, P., Kirtley, C., Leardini, A., Rosenbaum, D., Whittle, M., DʼLima, D. D., Cristofolini, L., Witte, H., et al. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00222-6 · Cited by 3,249
Müller, M., Heidelberger, B., Hennix, M., et al. (2007) · Journal of Visual Communication and Image Representation · doi:10.1016/j.jvcir.2007.01.005 · Cited by 935
Efficient Collision Detection of Complex Deformable Models using AABB Trees
van den Bergen, G. (1997) · Journal of Graphics Tools · doi:10.1080/10867651.1997.10487480 · Cited by 808
Collision and self-collision handling in cloth model dedicated to design garments
Provot, X. (1997) · Eurographics · doi:10.1007/978-3-7091-6874-5_13 · Cited by 331
Emerging Updates on the Posterior Cruciate Ligament
LaPrade, C. M., Civitarese, D. M., Rasmussen, M. T., et al. (2015) · The American Journal of Sports Medicine · doi:10.1177/0363546515572770 · Cited by 267
Amis, A. A., Bull, A. M. J., Gupte, C. M., Hijazi, I., Race, A., & Robinson, J. (2003) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-003-0410-7 · Cited by 201
Song, Y., Debski, R. E., Musahl, V., et al. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00261-6 · Cited by 176
A technique for quantifying the bending moment acting on the lumbar spine in vivo
Adams, M. A., & Dolan, P. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90356-r · Cited by 166
Measurement of in vivo anterior cruciate ligament strain during dynamic jump landing
Taylor, K. A., Terry, M. E., Utturkar, G. M., Spritzer, C. E., Queen, R. M., Irribarra, L. A., Garrett, W. E. J., & DeFrate, L. E. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.10.028 · Cited by 150
Jiang, Y. D., Lancianese, S. L., Hovinga, K. R., Lee, J. J., & Lerner, A. L. (2008) · Journal of Orthopaedic Research® · doi:10.1002/jor.20553 · Cited by 129
Duprey, S., Chèze, L. L., & Dumas, R. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.06.010 · Cited by 114
Leardini, A., Belvedere, C., Nardini, F., Sancisi, N., Conconi, M., & Parenti‐Castelli, V. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.04.029 · Cited by 88
The Effects of a Valgus Collapse Knee Position on In Vivo ACL Elongation
Utturkar, G. M., Irribarra, L. A., Taylor, K. A., Spritzer, C. E., Taylor, D. C., Garrett, W. E. J., & DeFrate, L. E. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0629-x · Cited by 76
Clément, J., Dumas, R., Hagemeister, N., et al. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.09.040 · Cited by 71
Sangeux, M., Marin, F., Charleux, F., Dürselen, L., & Tho, M. H. B. (2006) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.05.006 · Cited by 67
Ramaniraka, N. A., Terrier, A., Theumann, N. H., et al. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.11.014 · Cited by 65
Goyal, K., Tashman, S., Wang, J. H., et al. (2012) · The American Journal of Sports Medicine · doi:10.1177/0363546511435783 · Cited by 63
Impact on a simple physical model of the head
Kenner, V. H., & Goldsmith, W. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90032-8 · Cited by 57
Englander, Z. A., Baldwin, E. L., Smith, W. A. R., Garrett, W. E. J., Spritzer, C. E., & DeFrate, L. E. (2019) · The American Journal of Sports Medicine · doi:10.1177/0363546519876074 · Cited by 57
Validation of a multi-body optimization with knee kinematic models including ligament constraints
Gasparutto, X., Sancisi, N., Jacquelin, E., et al. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.01.010 · Cited by 53
Chandrasekaran, S., Ma, D., Scarvell, J. M., et al. (2012) · The Knee · doi:10.1016/j.knee.2012.09.005 · Cited by 53
Agolley, D., Gabr, A., Benjamin‐Laing, H., et al. (2017) · The Bone & Joint Journal · doi:10.1302/0301-620x.99b6.37953 · Cited by 48
The posterior cruciate ligament during flexion of the normal knee
Nakagawa, S., Johal, P., Pinskerová, V., et al. (2004) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.86b3.14330 · Cited by 46
Ali, A. A., Harris, M. D., Shalhoub, S. S., et al. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.04.008 · Cited by 42
Evaluation of a method to map tibiofemoral contact points in the normal knee using MRI
Scarvell, J. M., Smith, P. N., Refshauge, K. M., et al. (2003) · Journal of Orthopaedic Research® · doi:10.1016/j.orthres.2003.10.011 · Cited by 35
Mechanics of the anterior interval of the knee using open dynamic MRI
Dragoo, J. L., Phillips, C., Schmidt, J. D., Scanlan, S. F., Blazek, K., Steadman, J. R., & Williams, A. M. (2010) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2010.01.011 · Cited by 35
Kim, J. G., Lee, Y. S., Yang, B. S., Oh, S. J., & Yang, S. J. (2013) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-013-1854-y · Cited by 34
Richard, V., Cappozzo, A., & Dumas, R. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.01.030 · Cited by 34
Kim, H. Y., Seo, Y., Kim, H., Nguyenn, T., Shetty, N. S., & Yoo, Y.-S. (2011) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2011.05.012 · Cited by 32
Movement of the posterior cruciate ligament during knee flexion—MRI analysis
Komatsu, T., Kadoya, Y., Nakagawa, S., et al. (2004) · Journal of Orthopaedic Research® · doi:10.1016/j.orthres.2004.08.001 · Cited by 28
Richard, V., Lamberto, G., Lu, T., Cappozzo, A., & Dumas, R. (2016) · PLoS ONE · doi:10.1371/journal.pone.0157010 · Cited by 25
Evaluation of an intact, an ACL-deficient, and a reconstructed human knee joint finite element model
Vairis, A., Stefanoudakis, G., Petousis, M., et al. (2015) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2015.1015526 · Cited by 21
Clément, J., Dumas, R., Hagemeister, N., et al. (2016) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2016.1202935 · Cited by 20
Charbonnier, C., Lädermann, A., Kevelham, B., et al. (2017) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-017-1668-4 · Cited by 18
Self-citationKing, A. J., Deng, Q., Tyson, R. L., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0048714 · Cited by 13
Protocolo de reabilitação para as reconstruções isoladas do ligamento cruzado posterior
Cury, R. D. P. L., Kiyomoto, H. D., Rosal, G. F., Bryk, F. F., de Oliveira, V. M., & de Camargo, O. P. A. (2012) · Revista Brasileira de Ortopedia · doi:10.1590/s0102-36162012000400003 · Cited by 11
REHABILITATION PROTOCOL AFTER ISOLATED POSTERIOR CRUCIATE LIGAMENT RECONSTRUCTION
Cury, R. D. P. L., Kiyomoto, H. D., Rosal, G. F., Bryk, F. F., de Oliveira, V. M., & de Camargo, O. P. A. (2012) · Revista Brasileira de Ortopedia (English Edition) · doi:10.1016/s2255-4971(15)30122-1 · Cited by 11
Multi-body optimization with subject-specific knee models: performance at high knee flexion angles
Charbonnier, C., Chagué, S., Kolo, F. C., et al. (2017) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2017.1390568 · Cited by 5
Self-citation
Cited by
Sorted by citations
Xiao, Y., Ling, M., Liang, Z., Ding, J., Zhan, S., Hu, H., & Chen, B. (2021) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-021-02307-2 · Cited by 14
“Others also characterize knee joint kinematic function in three-dimensional (3D) based on MR images under weight-bearing conditions or measure length of ligament using MR images combined with motion capture system, but no further biomechanical analysis was performed [8, 9].”
Background
Metadata
- Authors
- Charbonnier, C., Duthon, V. B., Chagué, S., Kolo, F. C., & Ménétrey, J.
- Affiliations
- University of Geneva (CH)
- Hirslanden Clinique La Colline (CH)
- Corresponding author
- Charbonnier, Caecilia
- Venue
- International Journal of Computer Assisted Radiology and Surgery
- Published
- 2019-12-20
- Volume
- 15
- Issue
- 3
- Pages
- 555-564
- ISSN
- 1861-6410 (ISSN-L)
- 1861-6429
- OpenAlex
- W2995857557
- Cited by
- 6
- References
- 38
- Citations by year
- 2025: 1 · 2024: 1 · 2022: 2 · 2021: 2
- FWCI
- 0.95
- Type
- journal article
- Language
- en
- Open access
- Licence
- Locations
- International Journal of Computer Assisted Radiology and Surgery (publishedVersion)
- PubMed (publishedVersion)
- Archive ouverte UNIGE (University of Geneva) (acceptedVersion, other-oa)
- Topics
- Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Tendon Structure and Treatment
- Keywords
- posterior cruciate ligament, knee flexion angle, anterior cruciate ligament, collateral ligaments, knee rehabilitation, return to sport
- MeSH terms
- Adult, Biomechanical Phenomena, Exercise Therapy, Female, Humans, Knee Joint, Magnetic Resonance Imaging, Male, Movement, Range of Motion, Articular, Anterior Cruciate Ligament, Posterior Cruciate Ligament
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review