A review of mixed-potential type zirconia-based gas sensors
Open accessThe DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
A robust and reliable gas sensing device is considered as a convenient and practical solution for gas concentration monitoring that has become a mandatory requirement in different field of applications. For in situ hazardous gases detection, a mixed-potential type gas sensor has been regarded as a promising solid-state gas sensor. For the past three decades, there has been a significant progress in achieving high performance in mixed-potential type sensors. Therefore, this review is focused on reporting the development of mixed-potential type gas sensors with combined yttria-stabilized zirconia (YSZ) as the base solid electrolyte material and various classes of electrode materials for their potential utilization as a high-performance sensing electrode. The underlying sensing mechanism of a mixed-potential type YSZ-based sensor is elaborated here in detail. Transformation in design and configuration of this type of sensor is also covered in this report. In addition, recent progresses on mixed-potential type gas sensors development for detection of several target gases, such as carbon monoxide, hydrocarbons, nitrogen oxides, hydrogen, and ammonia, are reviewed. Strategies to improve the sensing characteristic, particularly gas sensitivity and selectivity, are also reported. Based on the understanding of the fundamental sensing mechanism and the requirements for high-performance gas sensors, challenges and future trends for this type of gas sensor development are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Busca, G., Lietti, L., Ramis, G., & Berti, F. (1998) · Applied Catalysis B: Environmental · doi:10.1016/s0926-3373(98)00040-x · Cited by 2,226
Ammonia sensors and their applications—a review
Timmer, B., Olthuis, W., & Berg, A. V. D. (2005) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2004.11.054 · Cited by 1,714
Metal oxide-based gas sensor research: How to?
BARSAN, N., KOZIEJ, D., & WEIMAR, U. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.09.047 · Cited by 1,696
Semiconducting metal oxides as sensors for environmentally hazardous gases
Wetchakun, K., Samerjai, T., Tamaekong, N., Liewhiran, C., Siriwong, C., Kruefu, V., Wisitsoraat, A., Tuantranont, A., & Phanichphant, S. (2011) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2011.08.032 · Cited by 1,241
Moseley, P. T. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/3/003 · Cited by 726
Gas sensors using carbon nanomaterials: A review
Llobet, E. (2013) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2012.11.014 · Cited by 692
Exhaust gas sensors for automotive emission control
Riegel, J. (2002) · Solid State Ionics · doi:10.1016/s0167-2738(02)00329-6 · Cited by 379
Advances and new directions in gas-sensing devices
Kim, I.-D., Rothschild, A., & Tuller, H. L. (2013) · Acta Materialia · doi:10.1016/j.actamat.2012.10.041 · Cited by 343
Materials and Transducers Toward Selective Wireless Gas Sensing
Potyrailo, R. A., Surman, C., Nagraj, N., & Burns, A. (2011) · Chemical Reviews · doi:10.1021/cr2000477 · Cited by 285
Solid-state mixed potential gas sensors: theory, experiments and challenges
Garzon, F. (2000) · Solid State Ionics · doi:10.1016/s0167-2738(00)00348-9 · Cited by 269
Highly selective CO sensor using stabilized zirconia and a couple of oxide electrodes
Miura, N., Raisen, T., Lu, G., & Yamazoe, N. (1998) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(98)00053-7 · Cited by 213
Self-citationPhysical Principles Governing Nonideal Behavior of the Zirconia Oxygen Sensor
Fleming, W. J. (1977) · Journal of The Electrochemical Society · doi:10.1149/1.2133235 · Cited by 197
High-temperature hydrogen sensor based on stabilized zirconia and a metal oxide electrode
Lu, G., Miura, N., & Yamazoe, N. (1996) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(97)80042-1 · Cited by 193
Self-citationMiura, N., Nakatou, M., & Zhuiykov, S. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00196-5 · Cited by 186
Self-citationSolid-state electrochemical gas sensors
Park, C. O., Fergus, J. W., Miura, N., Park, J., & Choi, A. (2009) · Ionics · doi:10.1007/s11581-008-0300-6 · Cited by 180
Self-citationProgress in mixed-potential type devices based on solid electrolyte for sensing redox gases
Miura, N. (2000) · Solid State Ionics · doi:10.1016/s0167-2738(00)00411-2 · Cited by 173
Self-citationMiura, N., Kurosawa, H., Hasei, M., Lu, G., & Yamazoe, N. (1996) · Solid State Ionics · doi:10.1016/0167-2738(96)00252-4 · Cited by 169
Self-citationFergus, J. W. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.07.005 · Cited by 147
Zhuiykov, S., Ono, T., Yamazoe, N., & Miura, N. (2002) · Solid State Ionics · doi:10.1016/s0167-2738(02)00331-4 · Cited by 144
Self-citationCarbon monoxide gas sensor made of stabilized zirconia
Okamoto, H., Obayashi, H., & KUDO, T. (1980) · Solid State Ionics · doi:10.1016/0167-2738(80)90012-0 · Cited by 133
Mixed Potential Type NO x Sensor Based on Stabilized Zirconia and Oxide Electrode
Miura, N., Lu, G., Yamazoe, N., Kurosawa, H., & Hasei, M. (1996) · Journal of The Electrochemical Society · doi:10.1149/1.1836448 · Cited by 130
Self-citationElumalai, P., Wang, J., Zhuiykov, S., Terada, D., Hasei, M., & Miura, N. (2005) · Journal of The Electrochemical Society · doi:10.1149/1.1923707 · Cited by 124
Self-citationSolid electrolyte based sensors for the measurement of CO and hydrocarbon gases
Fergus, J. W. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.06.024 · Cited by 122
Mixed-potential-type zirconia-based NO2 sensor with high-performance three-phase boundary
Liang, X., Yang, S., Li, J., Zhang, H., Diao, Q., Zhao, W., & Lu, G. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.02.051 · Cited by 120
Miura, N., Wang, J., Nakatou, M., Elumalai, P., Zhuiykov, S., & Hasei, M. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.08.009 · Cited by 118
Self-citationSelective mixed potential ammonia exhaust gas sensor
Schönauer‐Kamin, D., Wiesner, K., Fleischer, M., & Moos, R. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.04.064 · Cited by 115
Park, J., Yoon, B. Y., Park, C., Lee, W., & Lee, C. B. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.10.006 · Cited by 113
Sekhar, P. K., Brosha, E. L., Mukundan, R., Li, W., Nelson, M. A., Palanisamy, P., & Garzón, F. H. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.10.045 · Cited by 112
Mixed Potential Hydrocarbon Sensors based on a YSZ Electrolyte and Oxide Electrodes
Mukundan, R., Brosha, E. L., & Garzón, F. H. (2003) · Journal of The Electrochemical Society · doi:10.1149/1.1621880 · Cited by 93
Electrochemistry of Zirconia Gas Sensors
Zhuiykov, S. (2007) · CRC Press eBooks · doi:10.1201/9781420047622 · Cited by 89
Self-citationSensing Mechanism of Potentiometric Gas Sensors Based on Stabilized Zirconia with Oxide Electrodes
Bartolomeo, E. D., Grilli, M. L., & Traversa, E. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1695387 · Cited by 81
Mixed potential sensors using lanthanum manganate and terbium yttrium zirconium oxide electrodes
Brosha, E. L., Mukundan, R., Brown, D. R., & Garzón, F. H. (2002) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(02)00216-2 · Cited by 79
Miura, N., Yan, Y., Lu, G., & Yamazoe, N. (1996) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(96)01828-x · Cited by 78
Self-citationMixed potential NH3 sensor with LaCoO3 reference electrode
Lee, I., Jung, B.-H., Park, J., Lee, C., Hwang, J., & Park, C. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.09.009 · Cited by 76
Mixed-potential-type NOx sensor based on YSZ and zinc oxide sensing electrode
Miura, N., Akisada, K., Wang, J., Zhuiykov, S., & Ono, T. (2004) · Ionics · doi:10.1007/bf02410297 · Cited by 64
Self-citationBrosha, E. L., Mukundan, R., Lujan, R. W., & Garzón, F. H. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.12.044 · Cited by 59
Non‐Nernstian Behavior at Modified Au Electrodes for Hydrocarbon Gas Sensing
Hibino, T., Kakimoto, S., & Sano, M. (1999) · Journal of The Electrochemical Society · doi:10.1149/1.1392478 · Cited by 58
High temperature amperometric total NOx sensors with platinum-loaded zeolite Y electrodes
Yang, J.-C., & Dutta, P. K. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.10.052 · Cited by 51
Yang, J.-C., & Dutta, P. K. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.01.028 · Cited by 50
ONO, T. (2004) · Solid State Ionics · doi:10.1016/j.ssi.2004.04.044 · Cited by 49
Highly sensitive mixed-potential-type NO2 sensor using porous double-layer YSZ substrate
Yin, C., Guan, Y., Zhu, Z., Liang, X., Wang, B., Diao, Q., Zhang, H., Ma, J., Liu, F., Sun, Y., et al. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.03.064 · Cited by 48
Sato, T., Plashnitsa, V. V., Utiyama, M., & Miura, N. (2010) · Electrochemistry Communications · doi:10.1016/j.elecom.2010.01.034 · Cited by 44
Self-citationHibino, T. (1999) · Electrochemical and Solid-State Letters · doi:10.1149/1.1390937 · Cited by 42
Perovskite related electrode materials with enhanced NO sensitivity for mixed potential sensors
Zösel, J., Franke, D., Ahlborn, K., Gerlach, F., Vashook, V. V., & Guth, U. (2008) · Solid State Ionics · doi:10.1016/j.ssi.2008.01.044 · Cited by 40
Development and testing of a miniaturized hydrogen safety sensor prototype
Sekhar, P. K., Brosha, E. L., Mukundan, R., Nelson, M. A., Williamson, T. L., & Garzón, F. H. (2010) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2010.05.031 · Cited by 40
Mixed Potential Hydrogen Sensor Combining Oxide Ion Conductor with Oxide Electrode
Lu, G., Miura, N., & Yamazoe, N. (1996) · Journal of The Electrochemical Society · doi:10.1149/1.1836959 · Cited by 39
Self-citationNon-ideal emf behavior of zirconia oxygen sensors
Okamoto, H., Obayashi, H., & KUDO, T. (1981) · Solid State Ionics · doi:10.1016/0167-2738(81)90131-4 · Cited by 33
Hashimoto, A., Hibino, T., Mori, K., & Sano, M. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00931-5 · Cited by 32
Elumalai, P., Zösel, J., Guth, U., & Miura, N. (2009) · Ionics · doi:10.1007/s11581-009-0354-0 · Cited by 29
Self-citationPlashnitsa, V. V., Elumalai, P., Fujio, Y., Kawaguchi, T., & Miura, N. (2011) · Nanoscale · doi:10.1039/c1nr10091b · Cited by 29
Self-citationZirconia-based planar NO2 sensor using ultrathin NiO or laminated NiO–Au sensing electrode
Plashnitsa, V. V., Ueda, T., Elumalai, P., Kawaguchi, T., & Miura, N. (2007) · Ionics · doi:10.1007/s11581-007-0158-z · Cited by 29
Self-citationEffect of nanocomposite Au–YSZ electrodes on potentiometric sensor response to NO and CO
Striker, T., Ramaswamy, V., Armstrong, E. N., Willson, P., Wachsman, E. D., & Ruud, J. A. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.02.039 · Cited by 28
Sato, T., Plashnitsa, V. V., Utiyama, M., & Miura, N. (2011) · Journal of The Electrochemical Society · doi:10.1149/1.3573780 · Cited by 26
Self-citationYamaguchi, M., Anggraini, S. A., Fujio, Y., Breedon, M., Plashnitsa, V. V., & Miura, N. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.04.126 · Cited by 25
Self-citationAnggraini, S. A., Breedon, M., Ikeda, H., & Miura, N. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am403952w · Cited by 24
Self-citationSuetsugu, Y., Sato, T., Breedon, M., & Miura, N. (2011) · Electrochimica Acta · doi:10.1016/j.electacta.2011.08.108 · Cited by 23
Self-citationElumalai, P., Plashnitsa, V. V., Fujio, Y., & Miura, N. (2009) · Journal of The Electrochemical Society · doi:10.1149/1.3174390 · Cited by 20
Self-citationTeranishi, S., Kondo, K., Nishida, M., Kanematsu, W., & Hibino, T. (2009) · Electrochemical and Solid-State Letters · doi:10.1149/1.3156836 · Cited by 19
Wama, R., Plashnitsa, V. V., Elumalai, P., Kawaguchi, T., Fujio, Y., Utiyama, M., & Miura, N. (2009) · Journal of The Electrochemical Society · doi:10.1149/1.3090168 · Cited by 18
Self-citationSato, T., Breedon, M., & Miura, N. (2013) · Journal of The Electrochemical Society · doi:10.1149/2.007309jes · Cited by 14
Self-citationAnggraini, S. A., Breedon, M., & Miura, N. (2013) · Journal of The Electrochemical Society · doi:10.1149/2.091309jes · Cited by 10
Self-citation
Cited by
Editors’ Choice—Critical Review—A Critical Review of Solid State Gas Sensors
Hunter, G. W., Akbar, S., Bhansali, S., Daniele, M., Erb, P. D., Johnson, K., Liu, C.-C., Miller, D., Oralkan, O., Hesketh, P. J., et al. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab729c · Cited by 163
Ueda, T., Oide, N., Kamada, K., Hyodo, T., & Shimizu, Y. (2022) · ECS Sensors Plus · doi:10.1149/2754-2726/ac63d2 · Cited by 84
Editors’ Choice—Review—Recent Advances in Mixed Potential Sensors
Ramaiyan, K. P., & Mukundan, R. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67ab · Cited by 52
Zhang, Y., Liu, T., Wang, T., Li, W., Hao, X., Lu, Q., Yu, H., Liang, X., Liu, F., Liu, F., et al. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.130438 · Cited by 21
Cubic Bi 2 O 3 -Based Electrochemical Nitric Oxide Sensor Using Double Perovskite Oxide Electrodes
Bhardwaj, A., Bae, H., Mathur, L., Mathur, S., & Song, S.-J. (2022) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/aca2e0 · Cited by 7
Metadata
- Authors
- Miura, N., Sato, T., Anggraini, S. A., Ikeda, H., & Zhuiykov, S.
- Venue
- Ionics
- Published
- 2014-05-28
- Volume
- 20
- Issue
- 7
- Pages
- 901-925
- ISSN
- 0947-7047 (ISSN-L)
- 1862-0760
- OpenAlex
- W2074553389
- Cited by
- 334
- References
- 61
- FWCI
- 13.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.