The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Transvenous Lead Extraction: Heart Rhythm Society Expert Consensus on Facilities, Training, Indications, and Patient Management
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Systemic Infection Related to Endocarditis on Pacemaker Leads: Clinical Presentation and Management
Klug, D., Lacroix, D., Savoye, C., Goullard, L., Grandmougin, D., Hennequin, J. L., Kacet, S., & Lekieffre, J. (1997) · Circulation · doi:10.1161/01.cir.95.8.2098 · Cited by 593
Research works printed but not linked: 127
- Love, 2000, Recommendations for Extraction of Chronically Implanted Transvenous Pacing and Defibrillator Leads: Indications, Facilities, Training, Pacing Clin Electrophysiol. April, 23, 544, 10.1111/j.1540-8159.2000.tb00845.x · DOI · Paper page
- Lead Extraction 2008: Critical Review and Implementation of HRS Guidelines, HR 2008 satellite symposium co-sponsored by Cleveland Clinic and Heart Rhythm Society, Course directors Bruce Wilkoff, Charles Love, Charles Byrd, May 15, 2008. San Francisco, CA.
- Anderson, 1988, Inflammatory response to implants, ASAIO J, 11, 101, 10.1097/00002480-198804000-00005 · DOI · Paper page
- Stokes, 1986, Ten-year experience with implanted polyurethane lead insulation, Pacing Clin Electrophysiol, 9, 1160, 10.1111/j.1540-8159.1986.tb06687.x · DOI
- Stokes, 1990, The in vivo auto-oxidation of polyether polyurethanes by metal ions, J Biomater Sci Polym Ed, 1, 207, 10.1163/156856290X00062 · DOI
- Schoen, 1988, Biomaterial-associated calcification: pathology, mechanisms, and strategies for prevention, J Biomed Mater Res, 22, 11
- Hecker, 1985, Roughness and thrombogenicity of the outer surfaces of intravascular catheters, J Biomed Mater Res, 19, 381, 10.1002/jbm.820190404 · doi:10.1002/jbm.820190404
- Rozmus, 2005, Venous thrombosis and stenosis after implantation of pacemakers and defibrillators, J Interv Card Electrophysiol, 13, 9, 10.1007/s10840-005-1140-1 · doi:10.1007/s10840-005-1140-1
- Altman, 1998, Rotary bending fatigue of coils and wires used in cardiac lead design, J Biomed Mater Res, 43, 21, 10.1002/(SICI)1097-4636(199821)43:1<21::AID-JBM3>3.0.CO;2-O · doi:10.1002/(sici)1097-4636(199821)43:1<21::aid-jbm3>3.0.co;2-o
- Antonelli, 1998, Insulation lead failure: is it a matter of insulation coating, venous approach, or both?, Pacing Clin Electrophysiol, 21, 418, 10.1111/j.1540-8159.1998.tb00066.x · doi:10.1111/j.1540-8159.1998.tb00066.x
- Woscoboinik, 1992, Pacing lead survival: performance of different models, Pacing Clin Electrophysiol, 15, 1991, 10.1111/j.1540-8159.1992.tb03008.x · doi:10.1111/j.1540-8159.1992.tb03008.x
- Wilkoff, 2007, Lead failures: Dealing with even less perfect, Heart Rhythm, 4, 897, 10.1016/j.hrthm.2007.05.002 · doi:10.1016/j.hrthm.2007.05.002
- Goode, 1991, Development of a new technique for explantation of chronic transvenous pacemaker leads: five initial case studies, Biomed Instrum Technol, 25, 50
- Lakkireddy DR, Verma A, Wilkoff BL. Current concepts in intravascular pacemaker and defibrillator lead extraction, in New Arrhythmia Technologies. Editor: Paul J. Wang. Co-editors: Gerald V. Naccarelli, Michael R. Rosen, N.A. Mark Estes III, David L. Hayes, David E. Haines. 2005. pp 124–133. · doi:10.1002/9780470988725.ch14
- Love, 2007, Lead extraction, Heart Rhythm, 4, 1238, 10.1016/j.hrthm.2007.07.017 · DOI
- Verma, Atul, Wilkoff, Bruce L. Intravascular pacemaker and defibrillator lead extraction: A state-of-the-art review Heart Rhythm Volume:1, Issue:6, December, 2004. pp. 739–745. · doi:10.1016/j.hrthm.2004.09.020
- Jarwe, 1999, Single center experience with femoral extraction of permanent endocardial pacing leads, Pacing Clin Electrophysiol, 22, 1202, 10.1111/j.1540-8159.1999.tb00601.x · DOI
- Byrd, 1991, Intravascular techniques for extraction of permanent pacemaker leads, J Thorac Cardiovasc Surg, 101, 989, 10.1016/S0022-5223(19)36615-2 · doi:10.1016/s0022-5223(19)36615-2
- Byrd, 1990, Intravascular lead extraction using locking stylets and sheaths, Pacing Clin Electrophysiol, 13, 1871, 10.1111/j.1540-8159.1990.tb06906.x · doi:10.1111/j.1540-8159.1990.tb06906.x
- Belott, 2007, Lead extraction using the femoral vein, Heart Rhythm, 4, 1102, 10.1016/j.hrthm.2007.06.010 · doi:10.1016/j.hrthm.2007.06.010
- Byrd, 1985, Technique for the surgical extraction of permanent pacing leads and electrodes, J Thorac Cardiovasc Surg, 89, 142, 10.1016/S0022-5223(19)38860-9 · doi:10.1016/s0022-5223(19)38860-9
- Byrd, 2001, Advances in device lead extraction, Curr Cardiol Rep, 3, 324, 10.1007/s11886-001-0087-9 · doi:10.1007/s11886-001-0087-9
- Varma, 1998, Chronic atrial lead explantation using a staged percutaneous laser and open surgical approach, Pacing Clin Electrophysiol, 21, 1483, 10.1111/j.1540-8159.1998.tb00223.x · doi:10.1111/j.1540-8159.1998.tb00223.x
- Smith, 2008, Extraction of transvenous pacing and ICD leads, Pacing Clin Electrophysiol, 31, 736, 10.1111/j.1540-8159.2008.01079.x · DOI · Paper page
- Bongiorni, 2008, Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: high success rate and safety in more than 2000 leads, Eur Heart J, 29, 2886, 10.1093/eurheartj/ehn461 · doi:10.1093/eurheartj/ehn461
- Wilkoff, 1999, Pacemaker Lead Extraction with the Laser Sheath: Results of the Pacing Lead Extraction With the Excimer Sheath (PLEXES) Trial, Journal of the American College of Cardiology, 33, 1671, 10.1016/S0735-1097(99)00074-1 · DOI · Paper page
- Epstein, 1999, Initial Experience with Larger Laser Sheaths for the Removal of Transvenous Pacemaker and Implantable Defibrillator Leads, Circulation, 100, 516, 10.1161/01.CIR.100.5.516 · DOI
- Kennergren, 2007, PLESSE investigators group, Europace, 9, 651, 10.1093/europace/eum098 · DOI
- Neuzil, 2007, Pacemaker and ICD lead extraction with electrosurgical dissection sheaths and standard transvenous extraction systems: results of a randomized trial, Europace, 9, 98, 10.1093/europace/eul171 · DOI
- Borek, 2008, Pacemaker and ICD leads: Strategies for long-term management, J Interv Card Electrophysiol, 10.1007/s10840-008-9249-7 · DOI
- Jones, 2008, Large, single-center, single-operator experience with transvenous lead extraction: outcomes and changing indications, Heart Rhythm, 5, 520, 10.1016/j.hrthm.2008.01.009 · DOI · Paper page
- Saad, 2003, Nonthoracotomy implantable defibrillator lead extraction: results and comparison with extraction of pacemaker leads, Pacing Clin Electrophysiol, 26, 1944, 10.1046/j.1460-9592.2003.00300.x · DOI
- Mathur, 2003, Cardiac pacemaker lead extraction using conventional techniques: a single centre experience, Int J Cardiol, 91, 215, 10.1016/S0167-5273(03)00025-1 · doi:10.1016/s0167-5273(03)00025-1
- Byrd, 2001, Advances in device lead extraction, Curr Cardiol Rep, 3, 324, 10.1007/s11886-001-0087-9 · doi:10.1007/s11886-001-0087-9
- Kennergren, 2009, A single-centre experience of over one thousand lead extractions, Europace, 11, 612, 10.1093/europace/eup054 · DOI · Paper page
- Henrikson, 2008, How to prevent, recognize, and manage complications of lead extraction, Heart Rhythm, 5, 1083, 10.1016/j.hrthm.2007.10.018 · doi:10.1016/j.hrthm.2007.10.018
- Henrikson, 2008, How to prevent, recognize, and manage complications of lead extraction, Heart Rhythm, 5, 1221, 10.1016/j.hrthm.2007.10.017 · doi:10.1016/j.hrthm.2007.10.017
- Henrikson, 2008, How to prevent, recognize, and manage complications of lead extraction, Heart Rhythm, 5, 1352, 10.1016/j.hrthm.2008.02.037 · DOI
- Byrd, 2002, Clinical Study of the laser sheath for lead extraction: The total experience in the United States, Pacing Clin Electrophysiology, 25, 804, 10.1046/j.1460-9592.2002.t01-1-00804.x · DOI · Paper page
- Fearnot, 1990, Intravascular lead extraction using locking stylets, sheaths, and other techniques, Pacing Clin Electrophysiol, 13, 1864, 10.1111/j.1540-8159.1990.tb06905.x · doi:10.1111/j.1540-8159.1990.tb06905.x
- Smith, 1994, Five-years experience with intravascular lead extraction, Pacing Clin Electrophysiol, 17, 2016, 10.1111/j.1540-8159.1994.tb03792.x · DOI · Paper page
- Byrd, 1999, Intravascular extraction of problematic or infected permanent pacemaker leads: 1994–1996, Pacing Clin Electrophysiol, 22, 1348, 10.1111/j.1540-8159.1999.tb00628.x · DOI · Paper page
- Wilkoff, 1999, Trends in Intravascular Lead Extraction: Analysis of Data from 5339 Procedures in 10 Years, Pacing Clin Electrophysiol, 22, A207
- Bracke, 1998, Learning curve characteristics of pacing lead extraction with a laser sheath, Pacing Clin Electrophysiol, 21, 2309, 10.1111/j.1540-8159.1998.tb01172.x · DOI
- Smith, 1992, Intravascular extraction of chronic pacing leads: the effect of physician experience, Pacing Clin Electrophysiol, 15, 513
- Ghosh, 2005, Laser Lead Extraction, Pacing Clin Electrophysiol, 28, 180, 10.1111/j.1540-8159.2005.09368.x · DOI
- Naccarelli, 2008, Task Force 6: Training in Specialized Electrophysiology, Cardiac Pacing, and Arrhythmia Management, J Am Coll Cardiol, 51, 374, 10.1016/j.jacc.2007.11.014 · DOI
- Al-Khatib, 2005, The relation between patients' outcomes and the volume of cardioverter-defibrillator implantation procedures performed by physicians treating Medicare beneficiaries, J Am Coll Cardiol, 46, 1536, 10.1016/j.jacc.2005.04.063 · DOI · Paper page
- Binstadt, 2007, A Comprehensive Medical Simulation Education Curriculum for Emergency Medicine Residents Annals of Emergency Medicine, 49, 4
- Lammers, 2007, Simulation: The New Teaching Tool, Annals of Emergency Medicine, 49, 505, 10.1016/j.annemergmed.2006.11.001 · doi:10.1016/j.annemergmed.2006.11.001
- Bower, 1997, Using patient simulators to train surgical team members, AORN Journal, 65, 805, 10.1016/S0001-2092(06)63003-2 · doi:10.1016/s0001-2092(06)63003-2
- Rosen, 2008, The history of medical simulation, Journal of Critical Care, 23, 157, 10.1016/j.jcrc.2007.12.004 · DOI · Paper page
- Friedrich, 2002, Practice makes perfect: risk-free training with patient simulators, JAMA, 288, 2808
- Reznick, 2006, Teaching surgical skills—changes in the wind, N Engl J Med, 355, 2664, 10.1056/NEJMra054785 · DOI · Paper page
- Gallagher, 2004, Approval of virtual reality training for carotid stenting: what this means for procedural-based medicine, JAMA, 292, 3024, 10.1001/jama.292.24.3024 · DOI · Paper page
- Kennergren, 2000, Cardiac lead extraction with a novel locking stylet, J Interv Card Electrophysiol, 4, 591, 10.1023/A:1026561414148 · doi:10.1023/a:1026561414148
- Bongiorni, 2008, Intracardiac Echocardiography in patients with pacing and defibrillating leads: a Feasibility study, Echocardiography, 25, 632, 10.1111/j.1540-8175.2008.00656.x · DOI
- Fowler, 1997, Role of echocardiography in evaluation of patients with Staphylococcus aureus bacteremia: experience in 103 patients, J Am Coll Cardiol, 30, 1072, 10.1016/S0735-1097(97)00250-7 · DOI · Paper page
- Lo, 2006, Incidence and prognosis of pacemaker lead associated masses: a study of 1,569 transesophageal echocardiograms, J Invas Cardiol, 18, 599
- Zei, 2006, “Modified Temporary Cardiac Pacing Using Transvenous Active Fixation Leads and External Re-Sterilized Pulse Generators.”, J Am Coll Card, 47, 1487, 10.1016/j.jacc.2006.01.006 · DOI
- Trohman, 1991, Successful percutaneous extraction of a chronic left ventricular pacing lead, Pacing and Clinical Electrophysiology, 14, 1448, 10.1111/j.1540-8159.1991.tb04063.x · doi:10.1111/j.1540-8159.1991.tb04063.x
- Garrigue, 2001, Comparison of chronic biventricular pacing between epicardial and endocardial left ventricular stimulation using Doppler tissue imaging in patients with heart failure, Am J Cardiol, 88, 858, 10.1016/S0002-9149(01)01892-6 · DOI · Paper page
- Faris, 2003, Endocardial versus epicardial electrical synchrony during LV free-wall pacing, Am J Physiol Heart Circ Physiol, 285, H1864, 10.1152/ajpheart.00282.2003 · doi:10.1152/ajpheart.00282.2003
- van Gelder, 2007, Transseptal endocardial left ventricular pacing: an alternative technique for coronary sinus lead placement in cardiac resynchronization therapy, Heart Rhythm, 4, 454, 10.1016/j.hrthm.2006.11.023 · DOI
- Khan, 2005, Delayed lead perforation: a disturbing trend, Pacing Clin Electrophysiol, 28, 251, 10.1111/j.1540-8159.2005.40003.x · DOI · Paper page
- Laborderie, 2008, Management of subacute and delayed right ventricular perforation with a pacing or an implantable cardioverter-defibrillator lead, Am J Cardiol, 102, 1352, 10.1016/j.amjcard.2008.07.025 · doi:10.1016/j.amjcard.2008.07.025
- Champagne, 2002, Permanent pacemaker lead entrapment: role of the transesophageal echocardiography, Pacing Clin Electrophysiol, 25, 1131, 10.1046/j.1460-9592.2002.01131.x · DOI
- Henrikson, 2006, Computed tomography to assess possible cardiac lead perforation, Pacing Clin Electrophysiol, 29, 509, 10.1111/j.1540-8159.2006.00385.x · doi:10.1111/j.1540-8159.2006.00385.x
- Love CJ. Current concepts in extraction of transvenous pacing and ICD leads Cardiology Clinics, Volume 18, Issue 1, Pages 193–217. · doi:10.1016/s0733-8651(05)70134-x
- Zhan, 2007, Cardiac device implantation in the United States from 1997 through 2004: a population-based analysis, J Gen Intern Med, 23, 13
- Uslan, 2008, Temporal trends in permanent pacemaker implantation: a population-based study, Am Heart J, 155, 896, 10.1016/j.ahj.2007.12.022 · DOI · Paper page
- Lin, 2008, Age and gender trends in implantable cardioverter defibrillator utilization: a population based study, J Interv Card Electrophysiol, 22, 65, 10.1007/s10840-008-9213-6 · DOI
- Mond, 2004, The World survey of cardiac pacing and cardioverter defibrillators: calendar year 2001, Pacing Clin Electrophysiol, 27, 955, 10.1111/j.1540-8159.2004.00565.x · DOI
- Voigt, 2006, Rising rates of cardiac rhythm management device infections in the United States: 1996 through 2003, J Am Coll Cardiol, 48, 590, 10.1016/j.jacc.2006.05.016 · DOI · Paper page
- Hamid, 2009, Extraction of chronic pacemaker and defibrillator leads from the coronary sinus: laser infrequently used but required, Europace, 11, 213, 10.1093/europace/eun374 · doi:10.1093/europace/eun374
- Kasravi, 2005, Coronary sinus lead extraction in the era of cardiac resynchronization therapy: single center experience, Pacing Clin Electrophysiol, 28, 51, 10.1111/j.1540-8159.2005.09353.x · doi:10.1111/j.1540-8159.2005.09353.x
- Nagele, 2007, First experience with a new active fixation coronary sinus lead, Europace, 9, 437, 10.1093/europace/eum061 · doi:10.1093/europace/eum061
- Wilkoff, 2005, Improved extraction of ePTFE and medical adhesive modified defibrillation leads from the coronary sinus and great cardiac vein, Pacing Clin Electrophysiol, 28, 205, 10.1111/j.1540-8159.2005.40029.x · DOI
- Cesario, 2004, Azygos vein lead implantation: a novel adjunctive technique for implantable cardioverter defibrillator placement, J Cardiovasc Electrophysiol, 15, 780, 10.1046/j.1540-8167.2004.03649.x · doi:10.1046/j.1540-8167.2004.03649.x
- Chiu, 1998, Pacemaker lead extraction in pacemaker endocarditis with lead vegetation: usefulness of transesophageal echocardiography, Can J Cardiol, 14, 87
- Sohail, 2008, Infective endocarditis complicating permanent pacemaker and implantable cardioverter-defibrillator infection, Mayo Clin Proc, 83, 46, 10.4065/83.1.46 · DOI · Paper page
- Reek, 2003, Clinical efficacy of a wearable defibrillator in acutely terminating episodes of ventricular fibrillation using biphasic shocks, Pacing Clin Electrophysiol, 26, 2016, 10.1046/j.1460-9592.2003.00311.x · DOI
- Feldman, 2004, Use of a wearable defibrillator in terminating tachyarrhythmias in patients at high risk for sudden death: results of the WEARIT/BIROAD, Pacing Clin Electrophysiol, 27, 4, 10.1111/j.1540-8159.2004.00378.x · DOI · Paper page
- Uslan, 2007, Permanent pacemaker and implantable cardioverter defibrillator infection: a population-based study, Arch Intern Med, 167, 669, 10.1001/archinte.167.7.669 · DOI · Paper page
- Sohail, 2007, Risk factor analysis of permanent pacemaker infection, Clin Infect Dis, 45, 166, 10.1086/518889 · DOI · Paper page
- Klug, 2007, Risk factors related to infections of implanted pacemakers and cardioverter-defibrillators: results of a large prospective study, Circulation, 116, 1349, 10.1161/CIRCULATIONAHA.106.678664 · DOI · Paper page
- Uslan, 2006, Frequency of permanent pacemaker or implantable cardioverter-defibrillator infection in patients with gram-negative bacteremia, Clin Infect Dis, 43, 731, 10.1086/506942 · DOI
- Bailey, 2006, Complications of pacemakers and defibrillators in the elderly, Am J Geriatr Cardiol, 15, 102, 10.1111/j.1076-7460.2006.04815.x · DOI
- Klug, 2005, Detailed bacteriologic tests to identify the origin of transvenous pacing system infections indicate a high prevalence of multiple organisms, Am Heart J, 149, 322, 10.1016/j.ahj.2004.07.032 · DOI
- Wilkoff, 2007, How to treat and identify device infections, Heart Rhythm, 4, 1467, 10.1016/j.hrthm.2007.08.007 · DOI
- Chua, 2000, Diagnosis and management of infections involving implantable electrophysiologic cardiac devices, Ann Intern Med, 133, 604, 10.7326/0003-4819-133-8-200010170-00011 · DOI · Paper page
- Sohail, 2007, Management and outcome of permanent pacemaker and implantable cardioverter-defibrillator infections, J Am Coll Cardiol, 49, 1851, 10.1016/j.jacc.2007.01.072 · DOI · Paper page
- Baddour, 2001, Long-term suppressive antimicrobial therapy for intravascular device-related infections, Am J Med Sci, 322, 209, 10.1097/00000441-200110000-00011 · DOI · Paper page
- Chamis, 2001, Staphylococcus aureus bacteremia in patients with permanent pacemakers or implantable cardioverter-defibrillators, Circulation, 104, 1029, 10.1161/hc3401.095097 · DOI · Paper page
- Dy Chua, 2005, The role of swab and tissue culture in the diagnosis of implantable cardiac device infection, Pacing Clin Electrophysiol, 28, 1276, 10.1111/j.1540-8159.2005.00268.x · DOI
- Mansur, 1984, Dura mater valve endocarditis related to retained fragment of postoperative temporary epicardial pacemaker lead, Am Heart J, 108, 1049, 10.1016/0002-8703(84)90482-4 · doi:10.1016/0002-8703(84)90482-4
- Klug, 2003, Involvement of adherence and adhesion Staphylococcus epidermidis genes in pacemaker lead-associated infections, J Clin Microbiol, 41, 3348, 10.1128/JCM.41.7.3348-3350.2003 · DOI
- Klug, 2004, Local symptoms at the site of pacemaker implantation indicate latent systemic infection, Heart, 90, 882, 10.1136/hrt.2003.010595 · DOI · Paper page
- Uslan, 2006, Frequency of permanent pacemaker or implantable cardioverter-defibrillator infection in patients with gram-negative bacteremia, Clin Infect Dis, 43, 731, 10.1086/506942 · DOI
- Kay, 1999, The Risks of Spontaneous Injury and Extraction of an Active Fixation Pacemaker Lead: Report of the Accufix Multicenter Clinical Study and World-Wide Registry, Circulation, 100, 2344, 10.1161/01.CIR.100.23.2344 · DOI
- Lee, 2009, ICD lead proarrhythmia cured by lead extraction, Heart Rhythm, 6, 613, 10.1016/j.hrthm.2009.01.039 · DOI
- Gula, 2005, Central venous occlusion is not an obstacle to device upgrade with the assistance of laser extraction, Pacing Clin Electrophysiol, 28, 661, 10.1111/j.1540-8159.2005.00163.x · DOI
- Cooper, 2003, Implantable Cardioverter-Defibrillator Lead Complications and Laser Extraction in Children and Young Adults with Congenital heart Disease, J Cardiovasc Electrophys, 14, 344, 10.1046/j.1540-8167.2003.02500.x · DOI
- Fischer, 2009, Transfemoral snaring and stabilization of pacemaker and defibrillator leads to maintain vascular access during lead extraction, Pacing Clin Electrophysiol, 32, 336, 10.1111/j.1540-8159.2008.02241.x · doi:10.1111/j.1540-8159.2008.02241.x
- Chan, 2002, Percutaneous treatment for pacemaker-associated superior vena cava syndrome, Pacing Clin Electrophysiol, 25, 1628, 10.1046/j.1460-9592.2002.01628.x · doi:10.1046/j.1460-9592.2002.01628.x
- Worley, 2008, Over the wire lead extraction and focused force venoplasty to regain venous access in a totally occluded subclavian vein, J Interv Card Electrophysiol, 23, 135, 10.1007/s10840-008-9261-y · doi:10.1007/s10840-008-9261-y
- Henrikson, 2006, Laser recanalization of the subclavian vein, Pacing Clin Electrophysiol, 29, 436, 10.1111/j.1540-8159.2006.00368.x · doi:10.1111/j.1540-8159.2006.00368.x
- Pfitzner, 1998, Oversensing in a cardioverter defibrillator caused by interaction between two endocardial defibrillation leads in the right ventricle, Pacing and Clin Electrophysiol, 21, 764, 10.1111/j.1540-8159.1998.tb00136.x · doi:10.1111/j.1540-8159.1998.tb00136.x
- Lickfett, 1999, Inappropriate implantable defibrillator discharge caused by a retained pacemaker lead fragment, J Interv Card Electrophysiol, 3, 163, 10.1023/A:1009877715662 · doi:10.1023/a:1009877715662
- Lloyd, 1996, Extraction of the Telectronics Accufix 330-801 atrial lead: the Mayo Clinic experience, Mayo Clin Proc, 71, 230, 10.4065/71.3.230 · doi:10.4065/71.3.230
- Daoud, 1996, Evaluation and extraction of the Accufix atrial J lead, Am Heart J, 131, 266, 10.1016/S0002-8703(96)90352-X · doi:10.1016/s0002-8703(96)90352-x
- Kawanishi, 1998, Kaplan-Meier analysis of freedom from extraction or death in patients with an Accufix J retention wire atrial permanent pacemaker lead: a potential management tool, Pacing Clin Electrophysiol, 21, 2318, 10.1111/j.1540-8159.1998.tb01174.x · doi:10.1111/j.1540-8159.1998.tb01174.x
- Kawanishi, 1998, Spontaneous versus extraction related injuries associated with Accufix J-wire atrial pacemaker lead: tracking changes in patient management, Pacing Clin Electrophysiol, 21, 2314, 10.1111/j.1540-8159.1998.tb01173.x · doi:10.1111/j.1540-8159.1998.tb01173.x
- Kapa, 2008, Effects of scatter radiation on ICD and CRT function, Pacing Clin Electrophysiol, 31, 727, 10.1111/j.1540-8159.2008.01077.x · doi:10.1111/j.1540-8159.2008.01077.x
- Munshi, 2008, Radiation therapy planning of a breast cancer patient with in situ pacemaker–challenges and lessons, Acta Oncol, 47, 255, 10.1080/02841860701678779 · doi:10.1080/02841860701678779
- Nordbeck, 2009, Measuring RF-induced currents inside implants: Impact of device configuration on MRI safety of cardiac pacemaker leads, Magn Reson Med, 61, 570, 10.1002/mrm.21881 · DOI · Paper page
- Sutton, 2008, Safety of magnetic resonance imaging of patients with a new Medtronic EnRhythm MRI SureScan pacing system: clinical study design, Trials, 9, 68, 10.1186/1745-6215-9-68 · doi:10.1186/1745-6215-9-68
- Sommer, 2006, Strategy for safe performance of extrathoracic magnetic resonance imaging at 1.5 tesla in the presence of cardiac pacemakers in non-pacemaker-dependent patients: a prospective study with 115 examinations, Circulation, 114, 1285, 10.1161/CIRCULATIONAHA.105.597013 · DOI · Paper page
- Faris, 2006, Food and Drug Administration perspective: Magnetic resonance imaging of pacemaker and implantable cardioverter-defibrillator patients, Circulation, 114, 1232, 10.1161/CIRCULATIONAHA.106.647800 · DOI
- de Cock, 2000, Long-term outcome of patients with multiple (> or =3) noninfected transvenous leads: a clinical and echocardiographic study, Pacing Clin Electrophysiol, 23, 423, 10.1111/j.1540-8159.2000.tb00821.x · DOI
- Bracke, 2003, Venous occlusion of the access vein in patients referred for lead extraction: influence of patient and lead characteristics, Pacing Clin Electrophyisiol, 26, 1649, 10.1046/j.1460-9592.2003.t01-1-00247.x · doi:10.1046/j.1460-9592.2003.t01-1-00247.x
- Figa, 1997, Risk factors for venous obstruction in children with transvenous pacing leads, Pacing Clin Electrophysiol, 20, 1902, 10.1111/j.1540-8159.1997.tb03594.x · DOI
- Suga C, Hayes DL, Hyberger LK, Lloyd MA. Is there an adverse outcome from abandoned pacing leads? J Interv Card Electrophysiol 4:493–499. · DOI
- Bohm, 2001, Complications due to abandoned noninfected pacemaker leads, Pacing Clin Electrophysiol, 24, 1721, 10.1046/j.1460-9592.2001.01721.x · DOI
- Silvetti, 2008, Outcome of young patients with abandoned, nonfunctional endocardial leads, Pacing Clin Electrophysiol, 31, 473, 10.1111/j.1540-8159.2008.01017.x · DOI
- Glikson, 2009, Do abandoned leads pose risk to implantable cardioverter-defibrillator patients?, Heart Rhythm, 6, 65, 10.1016/j.hrthm.2008.10.012 · DOI
- Gould, 2006, Complications associated with implantable cardioverter-defibrillator replacement in response to device advisories, Jama, 295, 1907, 10.1001/jama.295.16.1907 · DOI · Paper page
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Wilkoff, B. L., Berul, C. I., Birgersdotter-Green, U. M., Carrillo, R., Cha, Y.-M., Clancy, J., Deharo, J.-C., Ellenbogen, K. A., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.09.001 · Cited by 1,199
Self-citationKhairy, P., Van Hare, G. F., Balaji, S., Berul, C. I., Cecchin, F., Cohen, M. I., Daniels, C. J., Deal, B. J., Dearani, J. A., Groot, N. D., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.05.009 · Cited by 709
Superior Vena Cava Defibrillator Coils Make Transvenous Lead Extraction More Challenging and Riskier
Epstein, L. M., Love, C. J., Wilkoff, B. L., Chung, M. K., Hackler, J. W., Bongiorni, M. G., Segreti, L., Carrillo, R. G., Baltodano, P., Fischer, A., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.12.014 · Cited by 467
Self-citationSandoe, J. A. T., Barlow, G., Chambers, J. B., Gammage, M., Guleri, A., Howard, P., Olson, E., Perry, J. D., Prendergast, B. D., Spry, M. J., et al. (2015) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dku383 · Cited by 403
Bongiorni, M. G., Burri, H., Deharo, J. C., Starck, C., Kennergren, C., Saghy, L., Rao, A., Tascini, C., Lever, N., Kutarski, A., et al. (2018) · EP Europace · doi:10.1093/europace/euy050 · Cited by 401
Self-citation
Metadata
- Authors
- Wilkoff, B. L., Love, C. J., Byrd, C. L., Bongiorni, M. G., Carrillo, R. G., Crossley, G. H., Epstein, L. M., Friedman, R. A., Kennergren, C. E. H., Mitkowski, P., Schaerf, R. H. M., & Wazni, O. M.
- Venue
- Heart Rhythm
- Publisher
- Elsevier BV
- Published
- 2009-07
- Volume
- 6
- Issue
- 7
- Pages
- 1085-1104
- ISSN
- 1547-5271 (ISSN-L)
- OpenAlex
- W2062398305
- Cited by
- 1,024
- References
- 1
- FWCI
- 40.73
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Funders
- Heart Rhythm Society
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transvenous Lead Extraction: Heart Rhythm Society Expert Consensus on Facilities, Training, Indications, and Patient Management. https://app.cochat.ai/papers/10.1016/j.hrthm.2009.05.020
- The paper
- Wilkoff, B. L., Love, C. J., Byrd, C. L., Bongiorni, M. G., Carrillo, R. G., Crossley, G. H., Epstein, L. M., Friedman, R. A., Kennergren, C. E. H., Mitkowski, P., Schaerf, R. H. M., & Wazni, O. M. (2009). Transvenous Lead Extraction: Heart Rhythm Society Expert Consensus on Facilities, Training, Indications, and Patient Management. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2009.05.020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.