The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Diagnostic accuracy of novel serological biomarkers to detect acute mesenteric ischemia: a systematic review and meta-analysis
Open accessAbstract
Laparotomy remains the gold standard for diagnosis of acute mesenteric ischemia (AMI), but is often unhelpful or too late due to non-specific clinical and radiological signs. This systematic review and meta-analysis aims to evaluate the diagnostic accuracy of the novel serological biomarkers intestinal fatty acid-binding protein (I-FABP), α-glutathione S-transferase (α-GST), D-lactate, ischemia modified albumin (IMA), and citrulline to detect AMI. A systematic search of electronic databases was performed to identify all published diagnostic accuracy studies on I-FABP, α-GST, D-lactate, IMA, and citrulline. Articles were selected based on pre-defined inclusion and exclusion criteria. Risk of bias and applicability were assessed. Two-by-two contingency tables were constructed to calculate accuracy standards. Summary estimates were computed using random-effects models. The search yielded 1925 papers, 21 were included in the final analysis. Pooled sensitivity and specificity for investigated biomarkers were: I-FABP (Uden); 79.0 (95% CI 66.5-88.5) and 91.3 (87.0-94.6), I-FABP (Osaka); 75.0 (67.9-81.2) and 79.2 (76.2-82.0), D-lactate; 71.7 (58.6-82.5) and 74.2 (69.0-79.0), α-GST; 67.8 (54.2-79.5) and 84.2 (75.3-90.9), IMA; 94.7 (74.0-99.9) and 86.4 (65.1-97.1), respectively. One study investigated accuracy standards for citrulline: sensitivity 39% and specificity 100%. The novel serological biomarkers I-FABP, α-GST, IMA, and citrulline may offer improved diagnostic accuracy of acute mesenteric ischemia; however, further research is required to specify threshold values and accuracy standards for different aetiological forms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“No breakthrough in defining a reliable biomarker with acceptable sensitivity and specificity was observed however [5, 6].”
From Diagnostic accuracy of biomarkers to detect acute mesenteric ischaemia in adult patients: a systematic review and meta-analysis (2023) · cites this paper as [5]
The cited source says what the claim attributes to it.
In the citing paper
“Novel biomarkers such as IMA and alpha glutathione S transferase (alpha-GST) were associated with great hope a few years ago, but no newer studies were identified than those in the systematic review by Treskes in 2017 [5].”
From Diagnostic accuracy of biomarkers to detect acute mesenteric ischaemia in adult patients: a systematic review and meta-analysis (2023) · cites this paper as [5]
The cited source says what the claim attributes to it.
In the citing paper
“Treskes et al. reported pooled sensitivity and specificity, respectively, for investigated biomarkers as follows: IFABP (human enzyme linked immunosorbent assay [ELISA] kit) 79.0% (95% CI 66.5 e 88.5%) and 91.3% (95% CI 87.0 e 94.6%);”
The cited source says what the claim attributes to it.
In the citing paper
“and ischaemia modified albumin 94.7% (95% CI 74.0 e 99.9%) and 86.4% (95% CI 65.1 e 97.1%). 124”
The cited source says what the claim attributes to it.
In the citing paper
“a -glutathione S-transferase 67.8% (95% CI 54.2 e 79.5%) and 84.2% (95% CI 75.3 e 90.9%);”
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000100 · Cited by 28,164
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.06.006 · Cited by 10,578
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Meta-DiSc: a software for meta-analysis of test accuracy data
Zamora, J., Abraira, V., Muriel, A., Khan, K., & Coomarasamy, A. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-31 · Cited by 1,883
Mannervik, B., Alin, P., Guthenberg, C., Jensson, H., Tahir, M. K., Warholm, M., & Jörnvall, H. (1985) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.82.21.7202 · Cited by 1,071
Bar–Or, D., Lau, E., & Winkler, J. V. (2000) · The Journal of Emergency Medicine · doi:10.1016/s0736-4679(00)00255-9 · Cited by 867
Crenn, P., Coudray–Lucas, C., Thuillier, F., Cynober, L., & Messing, B. (2000) · Gastroenterology · doi:10.1053/gast.2000.20227 · Cited by 498
ESTES guidelines: acute mesenteric ischaemia
Tilsed, J. V. T., Casamassima, A., Kurihara, H., Mariani, D., Martinez, I., Pereira, J., Ponchietti, L., Shamiyeh, A., al-Ayoubi, F., Barco, L. A. B., et al. (2016) · European Journal of Trauma and Emergency Surgery · doi:10.1007/s00068-016-0634-0 · Cited by 382
Cited by
Acute mesenteric ischemia: guidelines of the World Society of Emergency Surgery
Bala, M., Kashuk, J., Moore, E. E., Kluger, Y., Biffl, W., Gomes, C. A., Ben-Ishay, O., Rubinstein, C., Balogh, Z. J., Civil, I., et al. (2017) · World Journal of Emergency Surgery · doi:10.1186/s13017-017-0150-5 · Cited by 574
“(Recommendation 1C) Abbreviations alpha–GST: Serum alpha-glutathione S-transferase; AMI: Acute mesenteric ischemia; CABA: Cobalt-albumin binding assay; CMI: Chronic mesenteric ischemia; CTA: Computed tomography angiography; DCS: Damage control surgery; I-FABP: Intestinal fatty acid binding protein; MDCT: Multi-detecto…”
BackgroundAcute mesenteric ischemia: updated guidelines of the World Society of Emergency Surgery.
Bala, M., Catena, F., Kashuk, J., De Simone, B., Gomes, C. A., Weber, D., Sartelli, M., Coccolini, F., Kluger, Y., Abu-Zidan, F. M., et al. (2022) · World Journal of Emergency Surgery · doi:10.1186/s13017-022-00443-x · Cited by 380
“Other biomarkers reported to be of use in the diagnosis of AMI include intestinal fatty acid-binding protein (I-FABP), serum alpha-glutathione S-transferase (alphaGST), and cobalt–albumin binding assay (CABA) [55, 56].”
BackgroundResulton behalf of the Working Group on Gastrointestinal Function within the Section of Metabolism, E. A. N. (. S. O. E., Reintam Blaser, A., Preiser, J.-C., Fruhwald, S., Wilmer, A., Wernerman, J., Benstoem, C., Casaer, M. P., Starkopf, J., van Zanten, A., et al. (2020) · Critical Care · doi:10.1186/s13054-020-02889-4 · Cited by 219
Koelemay, M. J., Geelkerken, R. H., Kärkkäinen, J., Leone, N., Antoniou, G. A., de Bruin, J. L., Gombert, A., Gottsätter, A., Iborra, E., Ronchey, S., et al. (2025) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2025.06.010 · Cited by 123
Biochemical markers of acute intestinal ischemia: Possibilities and limitations
Montagnana, M., Danese, E., & Lippi, G. (2018) · Annals of Translational Medicine · doi:10.21037/atm.2018.07.22 · Cited by 108
Metadata
- Authors
- Treskes, N., Persoon, A. M., & van Zanten, A. R. H.
- Affiliations
- Ziekenhuis Gelderse Vallei (NL)
- St. Antonius Ziekenhuis (NL)
- Venue
- Internal and Emergency Medicine
- Published
- 2017-05-06
- Volume
- 12
- Issue
- 6
- Pages
- 821-836
- ISSN
- 1828-0447 (ISSN-L)
- 1970-9366
- PMC
- PMC5559578
- OpenAlex
- W2611677687
- Cited by
- 135
- References
- 63
- Citations by year
- 2026: 12 · 2025: 10 · 2024: 16 · 2023: 16 · 2022: 19 · 2021: 20 · 2020: 14 · 2019: 18 · 2018: 7 · 2017: 3
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Internal and Emergency Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Abdominal vascular conditions and treatments
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Sepsis Diagnosis and Treatment
- Health Sciences › Medicine › Emergency Medicine › Appendicitis Diagnosis and Management
- Keywords
- acute mesenteric ischemia, serological markers, diagnostic accuracy, intestinal fatty acid binding protein, alpha-glutathione S-transferase, D-lactate, ischemia-modified albumin, citrulline, intestinal ischemia
- MeSH terms
- Acute Disease, Humans, Predictive Value of Tests, Biomarkers, Mesenteric Ischemia
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic accuracy of novel serological biomarkers to detect acute mesenteric ischemia: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1007/s11739-017-1668-y
- The paper
- Treskes, N., Persoon, A. M., & van Zanten, A. R. H. (2017). Diagnostic accuracy of novel serological biomarkers to detect acute mesenteric ischemia: a systematic review and meta-analysis. Internal and Emergency Medicine. https://doi.org/10.1007/s11739-017-1668-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.