Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 163

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Improved separation of conjugated fatty acid methyl esters by silver ion‐high‐performance liquid chromatography

Sehat, Najibullah, Rickert, Rainer, Mossoba, Magdi M., Kramer, John K. G., Yurawecz, Martin P., Roach, John A. G., Adlof, Richard O., Morehouse, Kim M., Fritsche, Jan, Eulitz, Klaus D., Steinhart, Hans, Ku, Yuoh · 1999 · Lipids

Abstract

Operating from one to six silver ion‐high‐performance liquid chromatography (Ag+‐HPLC) columns in series progressively improved the resolution of the methyl esters of conjugated linoleic acid (CLA) isomeric mixtures from natural and commercial products. In natural products, the 8 trans, 10 cis‐octadecadienoic (18∶2) acid was resolved from the more abundant 7 trans, 9 cis‐18∶2, and the 10 trans, 12 cis‐18∶2 was separated from the major 9 cis, 11 trans‐18∶2 peak. In addition, both 11 trans, 13 cis‐18∶2 and 11 cis, 13 trans‐18∶2 isomers were found in natural products and were separated; the presence of the latter, 11 cis, 13 trans‐18∶2, was established in commercial CLA preparations. Three Ag+‐HPLC columns in series appeared to be the best compromise to obtain satisfactory resolution of most CLA isomers found in natural products. A single Ag+‐HPLC column in series with one of several normal‐phase columns did not improve the resolution of CLA isomers as compared to that of the former alone. The 20∶2 conjugated fatty acid isomers 11 cis, 13 trans‐20∶2 and 12 trans, 14 cis‐20∶2, which were synthesized by alkali isomerization from 11 cis, 14 cis‐20∶2, eluted in the same region of the Ag+‐HPLC chromatogram just before the corresponding geometric CLA isomers. Therefore, CLA isomers will require isolation based on chain length prior to Ag+‐HPLC separation. The positions of conjugated double bonds in 20∶2 and 18∶2 isomers were established by gas chromatography‐electron ionization mass spectrometry as their 4,4‐dimethyloxazoline derivatives. The double‐bond geometry was determined by gas chromatography‐direct deposition‐Fourier transform infrared spectroscopy and by the Ag+‐HPLC relative elution order.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s11745-999-0379-3

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 163

Metadata

Authors
Sehat, N., Rickert, R., Mossoba, M. M., Kramer, J. K. G., Yurawecz, M. P., Roach, J. A. G., Adlof, R. O., Morehouse, K. M., Fritsche, J., Eulitz, K. D., Steinhart, H., & Ku, Y.
Venue
Lipids
Publisher
Wiley
Published
1999-04
Volume
34
Issue
4
Pages
407-413
ISSN
  • 0024-4201 (ISSN-L)
  • 1558-9307
OpenAlex
W2077005399
Cited by
163
References
1
FWCI
7.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improved separation of conjugated fatty acid methyl esters by silver ion‐high‐performance liquid chromatography. https://app.cochat.ai/papers/10.1007/s11745-999-0379-3
The paper
Sehat, N., Rickert, R., Mossoba, M. M., Kramer, J. K. G., Yurawecz, M. P., Roach, J. A. G., Adlof, R. O., Morehouse, K. M., Fritsche, J., Eulitz, K. D., Steinhart, H., & Ku, Y. (1999). Improved separation of conjugated fatty acid methyl esters by silver ion‐high‐performance liquid chromatography. Lipids. https://doi.org/10.1007/s11745-999-0379-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.