CoChat

What is the Minimum Clinically Important Difference in Grip Strength?

Open access
Kim, Jae Kwang, Park, Min Gyue, Shin, Sung Joon · 2014 · Clinical Orthopaedics & Related Research
Cited by 182

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Grip strength reflects functional status of the upper extremity and has been used in many of the clinical studies regarding upper extremity disease or fracture. However, the smallest difference in grip strength that a patient would notice as an improvement resulting from treatment (defined as the minimum clinically important difference [MCID]), to our knowledge has not been determined. QUESTIONS/PURPOSES: We asked (1) how 1-year postsurgery grip strength compares with preinjury values; (2) if grip strength correlated with patient's ratings; (3) what the MCID is in the grip strength; and (4) if these values are equivalent to or greater than what can be explained by measurement errors in patients treated for distal radius fracture. METHODS: Fifty patients treated by volar locking plate fixation for a distal radius fracture constituted the study cohort. Grip strengths were measured 1 year after surgery on the injured and uninjured sides using a dynamometer. Grip strengths before injury were estimated using the grip strengths of the uninjured side with consideration of hand dominance. Patients were asked to rate their subjective level of grip strength weakness at 1 year postoperatively. Receiver operator characteristic curve analysis was used to determine MCIDs. Minimal detectable change in grip strength, which is a statistical estimate of the smallest change between two measurement points expected by measurement error or chance alone, also was determined using the formula 1.65 × √2 × standard error of measurement. RESULTS: One year after surgery, grip strength (23 kg; 95% CI, 20-27) was less compared with calculated preinjury values (28 kg; 95% CI, 25-31; p < 0.001). Patients' rating of grip strength and measured grip strength changes correlated well (p = 0.56). MCIDs were 6.5 kg for grip strength and 19.5% for percentage grip strength. The MCID was not less than the minimum detectable change for grip strength (also 6.5 kg). CONCLUSIONS: The MCID of the grip strength was a decrease of 6.5 kg (19.5%). We believe the MCID of grip strength is useful for evaluating effectiveness of new treatments and for determining appropriate sample size in clinical trials of distal radius fractures. LEVEL OF EVIDENCE: Level III diagnostic study. See the Instructions for Authors for a complete description of levels of evidence.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s11999-014-3666-y

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 182

Metadata

Authors
Kim, J. K., Park, M. G., & Shin, S. J.
Venue
Clinical Orthopaedics & Related Research
Published
2014-08
Volume
472
Issue
8
Pages
2536-2541
ISSN
0009-921X (ISSN-L)
OpenAlex
W2068562571
Cited by
182
References
15
FWCI
8.66
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: What is the Minimum Clinically Important Difference in Grip Strength? https://app.cochat.ai/papers/10.1007/s11999-014-3666-y
The paper
Kim, J. K., Park, M. G., & Shin, S. J. (2014). What is the Minimum Clinically Important Difference in Grip Strength? Clinical Orthopaedics & Related Research. https://doi.org/10.1007/s11999-014-3666-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.