What Was the Survival of Megaprostheses in Lower Limb Reconstructions After Tumor Resections?
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Prosthetic replacement is the most commonly used option for reconstruction of osteoarticular bone loss resulting from bone neoplasm resection or prosthetic failure. Starting in late 2001, we began exclusively using a single system for large-segment osteoarticular reconstruction after tumor resection; to our knowledge, there are no published series from one center evaluating the use of this implant. QUESTIONS/PURPOSES: We investigated the following issues: (1) What is the overall survival, excluding local tumor recurrence, for these endoprostheses used for tumor reconstructions of the lower extremities (knee and hip)? (2) What types of failure were observed in these reconstructions? (3) Do the survival and complications vary according to site of implant? METHODS: Between September 2001 and March 2012, we exclusively used this implant for tumor reconstructions. During that time, 278 patients underwent tumor reconstructions of the hip or knee, of whom 200 (72%) were available at a minimum 2 years followup. Seventy-eight patients were excluded from the study for insufficient followup as a result of early death (42) or loss at followup (36). The reconstruction types were the following: proximal femur (69 cases), distal femur (87), proximal tibia (32), and total knee (12). Failures were classified according to the Henderson classification. Nine patients among those with followup shorter than 2 years had presented one or more failures and they were included in our analysis but separately evaluated. RESULTS: Overall survival (no further surgical procedures of any type after primary surgery), excluding Type 5 failure (tumor recurrence), was 75.9% at 5 years and 66.2% at 10 years. Seventy-one failures occurred in 58 implants (29%). Mechanical failures accounted for 59.2% and nonmechanical failures for 40.8%. The first causes of failure of the implants were the result of soft tissue failure in 6%, aseptic loosening in 3%, structural failure in 7%, infection in 8.5%, and tumor recurrence in 4.5% of the whole series. Nine implants sustained two or more failures. Overall incidence of infection was 9.5%. No statistically significant differences were observed according to anatomical site. CONCLUSIONS: Like in the case with many such complex oncologic reconstructions, the failure rate at short- to midterm in this group was over 20%. Comparative trials are called for to ascertain whether one implant is superior to another. Infection and structural failure were the most frequent modes of failure in our experience. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Berry, D. J., Harmsen, W. S., Cabanela, M. E., & Morrey, B. F. (2002) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200202000-00002 · Cited by 679
The long-term results of endoprosthetic replacement of the proximal tibia for bone tumours
Myers, G. J. C., Abudu, A., Carter, S. R., Tillman, R. M., & Grimer, R. J. (2007) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.89b12.19481 · Cited by 184 · cited 2×
“The proximal tibia in fact is usually considered at highest risk for septic complications [18, 24, 27, 29].”
Late Complications and Survival of Endoprosthetic Reconstruction after Resection of Bone Tumors
Shehadeh, A. M., Noveau, J., Malawer, M. M., & Henshaw, R. M. (2010) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-010-1454-x · Cited by 162 · cited 3×
“Prosthetic replacement with modular implants has become the most common reconstructive technique of bone loss of the lower limb after tumor resection [1, 16, 17, 25, 26, 31, 33, 34].”
Söderman, P., Malchau, H., & Herberts, P. (2000) · Acta Orthopaedica Scandinavica · doi:10.1080/000164700317393330 · Cited by 146
Schwartz, A. J., Kabo, M. J., Eilber, F. C., Eilber, F. R., & Eċkardt, J. J. (2009) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-009-1197-8 · Cited by 132
Allograft-Prosthetic Composite in the Proximal Tibia After Bone Tumor Resection
Donati, D. M., Colangeli, M., Colangeli, S., Bella, C. D., & Mercuri, M. (2008) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-007-0055-9 · Cited by 120 · cited 2×
“For this reason, allograft-prosthesis composites have been introduced with the aim of combining the advantages of endoprostheses with the functional improvement resulting from biologic tendinous reattachment of the hip abductors and patellar tendon [2, 7, 8, 15, 38].”
Pala, E., Henderson, E. R., Calabrò, T., Angelini, A., Abati, C. N., Trovarelli, G., & Ruggieri, P. (2013) · Journal of Surgical Oncology · doi:10.1002/jso.23414 · Cited by 119 · cited 4×
“Prosthetic replacement with modular implants has become the most common reconstructive technique of bone loss of the lower limb after tumor resection [1, 16, 17, 25, 26, 31, 33, 34].”
InfluentialBenedetti, M. G., Bonatti, E., Malfitano, C., & Donati, D. M. (2013) · Acta Orthopaedica · doi:10.3109/17453674.2013.773119 · Cited by 72 · cited 2×
“For this reason, allograft-prosthesis composites have been introduced with the aim of combining the advantages of endoprostheses with the functional improvement resulting from biologic tendinous reattachment of the hip abductors and patellar tendon [2, 7, 8, 15, 38].”
Gilbert, N. F., Yasko, A. W., Oates, S. D., Lewis, V. O., Cannon, C. P., & Lin, P. P. (2009) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.g.01542 · Cited by 67 · cited 2×
“For this reason, allograft-prosthesis composites have been introduced with the aim of combining the advantages of endoprostheses with the functional improvement resulting from biologic tendinous reattachment of the hip abductors and patellar tendon [2, 7, 8, 15, 38].”
Multiple testing in orthopedic literature: a common problem?
Walenkamp, M. M. J., Roes, K. C. B., Bhandari, M., Goslings, J. C., & Schep, N. W. L. (2013) · BMC Research Notes · doi:10.1186/1756-0500-6-374 · Cited by 13 · cited 1×
“04 for differences among different reconstructions with distal femur and extraarticular knee reconstructions faring worse, but significance of this finding was not confirmed in analysis with Bonferroni correction [36].”
Cited by
Current and future therapeutic approaches for osteosarcoma
Harrison, D. J., Geller, D. S., Gill, J. D., Lewis, V. O., & Gorlick, R. (2018) · Expert Review of Anticancer Therapy · doi:10.1080/14737140.2018.1413939 · Cited by 689
Quality of life after bone sarcoma surgery around the knee: A long-term follow-up study
Bekkering, W. P., van Egmond-van Dam, J. C., Bramer, J. A. M., Beishuizen, A., Fiocco, M., & Dijkstra, P. D. S. (2017) · European Journal of Cancer Care · doi:10.1111/ecc.12603 · Cited by 28
Metadata
- Authors
- Capanna, R., Scoccianti, G., Frenos, F., Vilardi, A., Beltrami, G., & Campanacci, D. A.
- Venue
- Clinical Orthopaedics & Related Research
- Published
- 2015-03
- Volume
- 473
- Issue
- 3
- Pages
- 820-830
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W1988560818
- Cited by
- 159
- References
- 10
- FWCI
- 7.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: What Was the Survival of Megaprostheses in Lower Limb Reconstructions After Tumor Resections? https://app.cochat.ai/papers/10.1007/s11999-014-3736-1
- The paper
- Capanna, R., Scoccianti, G., Frenos, F., Vilardi, A., Beltrami, G., & Campanacci, D. A. (2015). What Was the Survival of Megaprostheses in Lower Limb Reconstructions After Tumor Resections? Clinical Orthopaedics & Related Research. https://doi.org/10.1007/s11999-014-3736-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.