Identifying cases of heroin toxicity where 6-acetylmorphine (6-AM) is not detected by toxicological analyses
Open accessThe DOI matches its Crossref record.
Abstract
PURPOSE: Heroin has a half-life of 2-6 min and is metabolized too quickly to be detected in autopsy samples. The presence of 6-acetylmophine (6-AM) in urine, blood, or other samples is convincing evidence of heroin use by a decedent, but 6-AM itself has a half-life of 6-25 min before it is hydrolyzed to morphine, so 6-AM may not be present in sufficient concentration to detect in postmortem samples. Codeine is often present in heroin preparations as an impurity and is not a metabolite of heroin. Studies report that a ratio of morphine to codeine greater than one indicates heroin use. We hypothesize that the ratio of morphine to codeine in our decedents abusing drugs intravenously will be no different in individuals with 6-AM present than in individuals where no 6-AM is detected, and we report our study of this hypothesis. METHODS: All accidental deaths investigated by the Jefferson County Coroner/Medical Examiner Office from 2010 to 2013 with morphine detected in blood samples collected at autopsy were reviewed. Five deaths where trauma caused or contributed to death were excluded from the review. The presence or absence of 6-AM and the concentrations of morphine and codeine were recorded for each case. The ratio of morphine to codeine was calculated for all decedents. Any individual in whom no morphine or codeine was detected in a postmortem sample was excluded from further study. Absence or presence of drug paraphernalia or evidence of intravascular (IV) drug use was documented in each case to identify IV drug users. The proportion of the IV drug users with and without 6-AM present in a postmortem sample was compared to the M/C ratio for the individuals. RESULTS: Of the 230 deaths included in the analysis, 103 IV drug users with quantifiable morphine and codeine in a postmortem sample were identified allowing for calculation of an M/C ratio. In these IV drug users, the M/C ratio was greater than 1 in 98 % of decedents. When controlling for the absence or presence of 6-AM there was no statistically significant difference in the proportion of IV drug users when compared to non IV drug users with an M/C ratio of greater than 1 (p = 1.000). CONCLUSION: The M/C ratio in IV drug users, if greater than 1, is seen in deaths due to heroin toxicity where 6-AM is detected in a postmortem sample. This study provides evidence that a M/C ratio greater than one in an IV drug user is evidence of a death due to heroin toxicity even if 6-AM is not detected in the blood. Using the M/C ratio, in addition to scene and autopsy findings, provides sufficient evidence to show heroin is the source of the morphine and codeine. Listing heroin as a cause or contributing factor in deaths with evidence of IV drug abuse and where the M/C ratio exceeds 1 will improve identification of heroin fatalities, which will allow better allocation of resources for public health initiatives.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Corrected US opioid‐involved drug poisoning deaths and mortality rates, 1999–2015
Ruhm, C. J. (2018) · Addiction · doi:10.1111/add.14144 · Cited by 169
Geographic variation in opioid and heroin involved drug poisoning mortality rates
Ruhm, C. J. (2017) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2017.06.009 · Cited by 152
Jones, A. W., Holmgren, A., & Ahlner, J. (2016) · Forensic Science International · doi:10.1016/j.forsciint.2016.08.015 · Cited by 41
A retrospective analysis of data from forensic toxicology at the Academy of Forensic Science in 2017
Pan, M., Wang, X., Zhao, Y., Liu, W., & Xiang, P. (2019) · Forensic Science International · doi:10.1016/j.forsciint.2019.02.039 · Cited by 31
Metadata
- Authors
- Ellis, A. D., McGwin, G., Davis, G. G., & Dye, D. W.
- Venue
- Forensic Science, Medicine, and Pathology
- Published
- 2016-04-25
- Volume
- 12
- Issue
- 3
- Pages
- 243-247
- ISSN
- 1547-769X (ISSN-L)
- 1556-2891
- OpenAlex
- W2344712368
- Cited by
- 40
- References
- 0
- FWCI
- 11.01
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.