The 2020 national diagnostic reference levels for nuclear medicine in Japan
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The diagnostic reference levels (DRLs) are one of several effective tools for optimizing nuclear medicine examinations and reducing patient exposure. With the advances in imaging technology and alterations of examination protocols, the DRLs must be reviewed periodically. The first DRLs in Japan were established in 2015, and since 5 years have passed, it is time to review and revise the DRLs. We conducted a survey to investigate the administered activities of radiopharmaceuticals and the radiation doses of computed tomography (CT) in hybrid CT accompanied by single photon emission computed tomography (SPECT)/CT and positron emission tomography (PET)/CT. We distributed a Web-based survey to 915 nuclear medicine facilities throughout Japan and survey responses were provided by 256 nuclear medicine facilities (response rate 28%). We asked for the facility's median actual administered activity and median radiation dose of hybrid CT when SPECT/CT or PET/CT was performed for patients with standard habitus in the standard protocol of the facility for each nuclear medicine examination. We determined the new DRLs based on the 75th percentile referring to the 2015 DRLs, drug package inserts, and updated guidelines. The 2020 DRLs are almost the same as the 2015 DRLs, but for the relatively long-lived radionuclides, the DRLs are set low due to the changes in the Japanese delivery system. There are no items set higher than the previous values. Although the DRLs determined this time are roughly equivalent to the DRLs used in the US, overall they tend to be higher than the European DRLs. The DRLs of the radiation dose of CT in hybrid CT vary widely depending on each imaging site and the purpose of the examination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preface, Executive Summary and Glossary
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.10.003 · Cited by 2,106
ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging
Vañó, E., Miller, D. L., Martin, C. J., Rehani, M. M., Kang, K., Rosenstein, M., Ortiz-López, P., Mattsson, S., Padovani, R., & Rogers, A. (2017) · Annals of the ICRP · doi:10.1177/0146645317717209 · Cited by 1,043
Limitations of diagnostic reference level (DRL) and introduction of acceptable quality dose (AQD)
Rehani, M. M. (2015) · The British Journal of Radiology · doi:10.1259/bjr.20140344 · Cited by 67
Cited by
Establishment of diagnostic reference levels in computed tomography in two large hospitals in Oman
Bouchareb, Y., Al-Maimani, A., Al-Balushi, A.-Y., Al-Kalbani, M., Al-Maskari, H., Al-Dhuhli, H., & Al-Kindi, F. (2023) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncad225 · Cited by 7
Alhorani, Q., Alkhybari, E., Rawashdeh, M., Sabarudin, A., Latiff, R. A., Al-Ibraheem, A., & Mohamad, M. (2024) · Journal of Radiological Protection · doi:10.1088/1361-6498/ad2c62 · Cited by 6
“For instance, this resulted in the NDRL for the AA of 18 F-FDG ranging from 240 to 590 MBq across nine countries [14, 15].”
InfluentialAloufi, K. M., Gameraddin, M., Alhazmi, F. H., Almazroui, I. S., Osman, H., & Khandaker, M. U. (2025) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2024.111583 · Cited by 5
Metadata
- Authors
- Abe, K., Hosono, M., Igarashi, T., Iimori, T., Ishiguro, M., Ito, T., Nagahata, T., Tsushima, H., & Watanabe, H.
- Venue
- Annals of Nuclear Medicine
- Published
- 2020-08-27
- Volume
- 34
- Issue
- 11
- Pages
- 799-806
- ISSN
- 0914-7187 (ISSN-L)
- 1864-6433
- OpenAlex
- W3081061444
- Cited by
- 72
- References
- 3
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.