Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Digital PET/CT allows for shorter acquisition protocols or reduced radiopharmaceutical dose in [18F]-FDG PET/CT

Open access

Abstract

Purpose: To establish the feasibility of shorter acquisition times (and by analogy, applied activity) on tumour detection and lesion contrast in digital PET/CT. Methods: Twenty-one randomly selected patients who underwent oncological [18 F]-FDG PET/CT on a digital PET/CT were retrospectively evaluated. Scan data were anonymously obtained and reconstructed in list-mode acquisition for a standard 2 min/bed position (bp), 1 min/bp and 30 s/bp (100%, 50% and 25% time or applied activity, respectively). Scans were randomized and read by two nuclear medicine physicians in a consensus read. Readers were blind to clinical details. Scans were evaluated for the number of pathological lesions detected. Measured uptake for lesions was evaluated by maximum and mean standardized uptake value (SUVmax and SUVmean, respectively) and tumour-to-backround ratio (TBR) were compared. Agreement between the three acquisitions was compared by Krippendorf’s alpha. Results: Overall n = 100 lesions were identified in the 2 min and 1 min/bp acquisitions and n = 98 lesions in the 30 s/bp acquisitions. Agreement between the three acquisitions with respect to lesion number and tumour-to-background ratio showed almost perfect agreement (K’s α = 0.999). SUVmax, SUVmean and TBR likewise showed > 98% agreement, with longer acquisitions being associated with slightly higher mean TBR (2 min/bp 7.94 ± 4.41 versus 30 s/bp 7.84 ± 4.22, p < 0.05). Conclusion: Shorter acquisition times have traditionally been associated with reduced lesion detectability or the requirement for larger amounts of radiotracer activity. These data confirm that this is not the case for new-generation digital PET scanners, where the known higher sensitivity results in clinically adequate images for shorter acquisitions. Only a small variation in the semi-quantitative parameters SUVmax, SUVmean and TBR was seen, confirming that either reduction of acquisition time or (by analogy) applied activity can be reduced as much as 75% in digital PET/CT without apparent clinical detriment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s12149-021-01588-6

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Tumour-to-background ratio for the three acquisitions [30 s/bed position (bp); 1 min/bp; 2 min/bp]. The bars represent the standard error in the mean. No clear relationship between list-mode acquisition length and TBR was observed
Fig. 1 Tumour-to-background ratio for the three acquisitions [30 s/bed position (bp); 1 min/bp; 2 min/bp]. The bars represent the standard error in the mean. No clear relationship between list-mode acquisition length and TBR was observedCC BY · PubMed Central
Fig. 2 Example of lesion missed at shorter acquisition (30 s/bp) but easily identified at 1 min and 2 min/bp list-mode acquisition. This retropharyngeal lymph node (blue arrow) was overlooked owing to increased noise in the 30 s/bp acquisitions, and is much better delineated at 2 min and 1 min/bp. The top row represents the PET data, the bottom row fusion of PET and CT. Bottom right shows colour look-up table (scale 0–8 SUV)
Fig. 2 Example of lesion missed at shorter acquisition (30 s/bp) but easily identified at 1 min and 2 min/bp list-mode acquisition. This retropharyngeal lymph node (blue arrow) was overlooked owing to increased noise in the 30 s/bp acquisitions, and is much better delineated at 2 min and 1 min/bp. The top row represents the PET data, the bottom row fusion of PET and CT. Bottom right shows colour look-up table (scale 0–8 SUV)CC BY · PubMed Central
Fig. 3 Example of increased noise for the 30 s/bp acquisitions in the maximum intensity projection images (MIP), left most image 2 min/bp, middle 1 min/bp, rightmost 30 s/bp. Note that the increased noise, while subjectively reducing image quality, does not influence the detectability of mediastinal and cervical lymph node lesions in this patient
Fig. 3 Example of increased noise for the 30 s/bp acquisitions in the maximum intensity projection images (MIP), left most image 2 min/bp, middle 1 min/bp, rightmost 30 s/bp. Note that the increased noise, while subjectively reducing image quality, does not influence the detectability of mediastinal and cervical lymph node lesions in this patientCC BY · PubMed Central
Fig. 4 SUVmax for each lesion by acquisition duration (light grey). In bold (black) is the mean SUVmax ± standard deviation
Fig. 4 SUVmax for each lesion by acquisition duration (light grey). In bold (black) is the mean SUVmax ± standard deviationCC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Research works printed but not linked: 1

  1. van Sluis J, Boellaard R, Dierckx RA, Stormezand G, Glaudemans A, Noordzij W. Image quality and activity optimization in oncological (18)F-FDG PET using the digital Biograph Vision PET/CT. J Nucl Med. 2019. https://doi.org/10.2967/jnumed.119.234351. · DOI

Cited by

See all 70

Metadata

Authors
Alberts, I., Sachpekidis, C., Prenosil, G., Viscione, M., Bohn, K. P., Mingels, C., Shi, K., Ashar-Oromieh, A., & Rominger, A.
Affiliations
University of Bern (CH)
Corresponding author
Alberts, Ian
Venue
Annals of Nuclear Medicine
Published
2021-02-07
Volume
35
Issue
4
Pages
485-492
ISSN
  • 0914-7187 (ISSN-L)
  • 1864-6433
OpenAlex
W3127712352
Cited by
70
References
27
Citations by year
2026: 10 · 2025: 12 · 2024: 14 · 2023: 13 · 2022: 17 · 2021: 4
FWCI
6.33
Type
journal article
Language
en
Open access
Licence
Locations
  • Annals of Nuclear Medicine (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • BORIS (University Library Bern) (submittedVersion, cc-by)
  • eScholarship (California Digital Library) (submittedVersion, cc-by)
Funders
Universität Bern
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
Keywords
digital PET/CT, 18F-FDG, acquisition time reduction, list-mode reconstruction, cancer detection, lesion contrast, tumor-to-background ratio, standardized uptake value, scanner sensitivity
MeSH terms
Positron Emission Tomography Computed Tomography, Body Weight, Humans, Image Processing, Computer-Assisted, Neoplasms, Retrospective Studies, Sensitivity and Specificity, Radiopharmaceuticals, Fluorodeoxyglucose F18, Signal-To-Noise Ratio

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Digital PET/CT allows for shorter acquisition protocols or reduced radiopharmaceutical dose in [18F]-FDG PET/CT. https://app.cochat.ai/papers/10.1007/s12149-021-01588-6
The paper
Alberts, I., Sachpekidis, C., Prenosil, G., Viscione, M., Bohn, K. P., Mingels, C., Shi, K., Ashar-Oromieh, A., & Rominger, A. (2021). Digital PET/CT allows for shorter acquisition protocols or reduced radiopharmaceutical dose in [18F]-FDG PET/CT. Annals of Nuclear Medicine. https://doi.org/10.1007/s12149-021-01588-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.