The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Noise Considerations for PET Quantification Using Maximum and Peak Standardized Uptake Value
Open accessAbstract
UNLABELLED: In tumor response monitoring studies with (18)F-FDG PET, maximum standardized uptake value (SUV(max)) is commonly applied as a quantitative metric. Although it has several advantages due to its simplicity of determination, concerns about the influence of image noise on single-pixel SUV(max) persist. In this study, we measured aspects of bias and reproducibility associated with SUV(max) and the closely related peak SUV (SUV(peak)) using real patient data to provide a realistic noise context. METHODS: List-mode 3-dimensional PET data were acquired for 15 min over a single bed position in twenty (18)F-FDG oncology patients. For each patient, data were sorted so as to form 2 sets of images: respiration-gated images such that each image had statistical quality comparable to a 3 min/bed position scan, and 5 statistically independent (ungated) images of different durations (1, 2, 3, 4, and 5 min). Tumor SUV(max) and SUV(peak) (12-mm-diameter spheric region of interest positioned so as to maximize the enclosed average) were analyzed in terms of reproducibility and bias. The component of reproducibility due to statistical noise (independent of physiologic and other variables) was measured using paired SUVs from 2 comparable respiration-gated images. Bias was measured as a function of scan duration. RESULTS: Replicate tumor SUV measurements had a within-patient SD of 5.6% ± 0.9% for SUV(max) and 2.5% ± 0.4% for SUV(peak). SUV(max) had average positive biases of 30%, 18%, 12%, 4%, and 5% for the 1-, 2-, 3-, 4-, and 5-min images, respectively. SUV(peak) was also biased but to a lesser extent: 11%, 8%, 5%, 1%, and 4% for the 1-, 2-, 3-, 4-, and 5-min images, respectively. CONCLUSION: The advantages of SUV(max) are best exploited when PET images have a high statistical quality. For images with noise properties typically associated with clinical whole-body studies, SUV(peak) provides a slightly more robust alternative for assessing the most metabolically active region of tumor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946
A Systematic Review of the Factors Affecting Accuracy of SUV Measurements
Adams, M. C., Turkington, T. G., Wilson, J. M., & Wong, T. Z. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.10.4923 · Cited by 662
Cited by
Practical PERCIST: A Simplified Guide to PET Response Criteria in Solid Tumors 1.0
O, J. H., Lodge, M. A., & Wahl, R. L. (2016) · Radiology · doi:10.1148/radiol.2016142043 · Cited by 521
Self-citationA review on segmentation of positron emission tomography images
Foster, B., Bagci, U., Mansoor, A., Xu, Z., & Mollura, D. J. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.04.014 · Cited by 370
Repeatability of SUV in Oncologic 18F-FDG PET
Lodge, M. A. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.186353 · Cited by 214
Self-citationFeasibility of state of the art PET/CT systems performance harmonisation
Kaalep, A., Sera, T., Rijnsdorp, S., Yaqub, M., Talsma, A., Lodge, M. A., & Boellaard, R. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-3977-4 · Cited by 160
Self-citationSher, A., Lacoeuille, F., Fosse, P., Vervueren, L., Cahouet-Vannier, A., Dabli, D., Bouchet, F., & Couturier, O. (2016) · EJNMMI Research · doi:10.1186/s13550-016-0177-8 · Cited by 111
Metadata
- Authors
- Lodge, M. A., Chaudhry, M. A., & Wahl, R. L.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2012-05-24
- Volume
- 53
- Issue
- 7
- Pages
- 1041-1047
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W1968597302
- Cited by
- 226
- References
- 4
- FWCI
- 9.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noise Considerations for PET Quantification Using Maximum and Peak Standardized Uptake Value. https://app.cochat.ai/papers/10.2967/jnumed.111.101733
- The paper
- Lodge, M. A., Chaudhry, M. A., & Wahl, R. L. (2012). Noise Considerations for PET Quantification Using Maximum and Peak Standardized Uptake Value. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.111.101733
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.