Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES): a Powerful Analytical Technique for Elemental Analysis
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Semiconductor ultraviolet detectors
Razeghi, M., & Rogalski, A. (1996) · Journal of Applied Physics · doi:10.1063/1.362677 · Cited by 1,477
Bruins, A. P., Covey, T. R., & Henion, J. D. (1987) · Analytical Chemistry · doi:10.1021/ac00149a003 · Cited by 879 · cited 1×
“In the case of the ICP-OES instrument, firstly samples are converted into liquid form, and with the help of a peristaltic pump, samples are pumped into the instrument by a device named a nebulizer which converts the liquid into an aerosol or mist (Bruins et al. 1987).”
MethodHandbook of Inductively Coupled Plasma Spectrometry
Thompson, M., & Walsh, J. N. (1989) · Springer eBooks · doi:10.1007/978-1-4613-0697-9 · Cited by 502 · cited 6×
“2013; Thompson 2012).”
BackgroundMethodInfluentialAescin: pharmacology, pharmacokinetics and therapeutic profile
Sirtori, C. R. (2001) · Pharmacological Research · doi:10.1006/phrs.2001.0847 · Cited by 423 · cited 2×
“Nowadays, formulations from plant origin have been widely developed and marked by many industries for medicinal as well as nutraceutical purpose (Sirtori 2001; Jarzebski et al. 2019).”
BackgroundAnalytical Chemistry in Archaeology
Pollard, A. M., Batt, C. M., Stern, B., & Young, S. M. M. (2007) · Cambridge University Press eBooks · doi:10.1017/cbo9780511607431 · Cited by 382
Günther, D., Jackson, S. E., & Longerich, H. P. (1999) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/s0584-8547(99)00011-7 · Cited by 249 · cited 1×
“In a nutshell, sample introduction techniques studies in an ICP-OES instrument have been a broad area and will continue to be an active area of research soon (Günther et al. 1999).”
MethodDynamics of Short-Pulse Excitation, Ionization and Harmonic Conversion
Kulander, K. C., Schafer, K. J., & Krause, J. L. (1993) · NATO ASI Series · doi:10.1007/978-1-4615-7963-2_10 · Cited by 234 · cited 1×
“When electrons return from an excited energy level to a lower energy level, ions and atoms release photons which are called ionic or atomic emission, and the emission is then collected to a detector using Echelle or Rowland circle optics, which separate different emission wavelengths from each other (Kulander et al. 1…”
BackgroundThe determination of trace elements in crude oil and its heavy fractions by atomic spectrometry
Duyck, C., Miekeley, N., Porto da Silveira, C. L., Aucélio, R. Q., Campos, R. C., Grinberg, P., & Brandão, G. P. (2007) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2007.04.013 · Cited by 187 · cited 1×
“The ICP-OES technique is not ideally suited as a part of the sample introduction system with any other chromatographic technique like gas chromatography (GC) or liquid chromatography (LC), whereas the ICP-MS is ideally suited with chromatographic techniques (Duyck et al. 2007).”
Balaram, V. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.02.001 · Cited by 186 · cited 2×
“Nowadays, ICPOES has proved to be an important instrument in elemental impurities determination in various sample matrices and is being used in the various pharmaceutical industries to measure trace metal contents of active pharmaceutical ingredients (API) or intermediates against specification limits specified in var…”
BackgroundInductively Coupled Plasma‐Optical Emission Spectrometry
Hou, X., & Jones, B. T. (2008) · Encyclopedia of Analytical Chemistry · doi:10.1002/9780470027318.a5110.pub2 · Cited by 174 · cited 2×
“Each of the exit slit polychromators is aligned to a specific element and the most popular configuration in polychromator type is the Paschen-Runge mount type (Hou et al. 2006; Wang 2004).”
BackgroundMethodKhan, N., Jeong, I. S., Hwang, I. M., Kim, J. S., Choi, S. H., Nho, E. Y., Choi, J. Y., Kwak, B., Ahn, J., Yoon, T., et al. (2013) · Food Chemistry · doi:10.1016/j.foodchem.2013.06.034 · Cited by 145 · cited 1×
“The results revealed that the sample preparation techniques of wet digestion and microwave provided satisfactory results (Khan et al. 2013).”
ResultRecent advances in inductively coupled plasma optical emission spectrometry
Donati, G. L., Amais, R. S., & Williams, C. B. (2017) · Journal of Analytical Atomic Spectrometry · doi:10.1039/c7ja00103g · Cited by 141 · cited 1×
“In ICP-OES, a sample usually introduced as a liquid sample into the instrument that is injected towards the central channel of radiofrequency (RF) induced argon plasma, where a liquid sample is transformed in the form of an aerosol called as the aerosol nebulization process, whereas solid samples previously required t…”
BackgroundKannamkumarath, S. S., Wróbel, K., Wróbel, K., B’Hymer, C., & Caruso, J. A. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01218-9 · Cited by 137 · cited 1×
“The mass detector coupled with ICPMS makes this hyphenation technique highly sensitive and highly specific as compared to ICP-OES and this hyphenation technique leads to the identification of the compound via mass to charge ratio (Kannamkumarath et al. 2002).”
MethodBakircioglu, D., Kurtulus, Y. B., & Yurtsever, S. (2012) · Food Chemistry · doi:10.1016/j.foodchem.2012.10.089 · Cited by 133 · cited 3×
“Trace elements like Mg, Mn, and Co responsible for oil rancidity while ill-effects in humans are caused by elements such as Cd, Hg, and Pb (Bakircioglu et al. 2013).”
BackgroundMethodInfluentialLi, L., Chen, Y., Yang, L., Wang, Z., & Liu, H. (2020) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213235 · Cited by 100 · cited 1×
“It is a modern and multi-functional analytical technique that is primarily used for the analysis of an element in different samples like environmental, industrial, plant, tissue, and pharmaceutical samples with a wide variety of concentrations (Li et al. 2020).”
BackgroundAguilera, J. A., Aragón, C., Cristoforetti, G., & Tognoni, E. (2009) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2009.06.002 · Cited by 100 · cited 1×
“The detector then measures the emission signal intensities of respective wavelengths and this emission wavelength corresponds to the energy difference between the excited state and ground state of the electron and the emission signal strength is proportional to the element’s abundance in the plasma (Bibinov et al. 200…”
BackgroundPhotocurrent generation in lateral graphene p-n junction created by electron-beam irradiation
Yu, X., Shen, Y., Liu, T., Wu, T., & Wang, Q. J. (2015) · Scientific Reports · doi:10.1038/srep12014 · Cited by 85 · cited 1×
“In the 1960s, solid-state devices based on silicon properties such as transistors and diodes were introduced into the electronic sector in the form of an integrated circuit (IC), which were expanded to the digital sector electronics and the cost of these devices and systems such as digital computers, was gradually red…”
BackgroundDevelopment of an atomic fluorescence spectrometer for the hydride-forming elements
Corns, W. T., Stockwell, P. B., Ebdon, L., & Hill, S. J. (1993) · Journal of Analytical Atomic Spectrometry · doi:10.1039/ja9930800071 · Cited by 78 · cited 1×
“At its core, ICP-OES maintains very high temperatures (8000–10000K) to rapidly dry and vaporized the aerosol, releasing the elements as an analyte in the gaseous state as free atoms (Warren 1993).”
BackgroundThiagarajan, V., Selvaraju, C., Malar, E. J. P., & Ramamurthy, P. (2004) · ChemPhysChem · doi:10.1002/cphc.200400064 · Cited by 76 · cited 1×
“The detector then measures the emission signal intensities of respective wavelengths and this emission wavelength corresponds to the energy difference between the excited state and ground state of the electron and the emission signal strength is proportional to the element’s abundance in the plasma (Bibinov et al. 200…”
BackgroundCortez, J., & Pasquini, C. (2013) · Analytical Chemistry · doi:10.1021/ac302755h · Cited by 69 · cited 2×
“2013; Cortez and Pasquini 2013).”
BackgroundD’Archivio, A. A., Foschi, M., Aloia, R., Maggi, M. A., Rossi, L., & Ruggieri, F. (2018) · Food Chemistry · doi:10.1016/j.foodchem.2018.09.088 · Cited by 64 · cited 3×
“Therefore, %RSD was still below 15 % of the analyzed components which is within the acceptable limits for ICP-OES analysis and for most of the garlic samples, the recovery rate of each garlic sample was determined and acceptable mean recoveries (86–95%) were observed (D’Archivio et al. 2019).”
BackgroundMethodInfluentialKarasakal, A. (2020) · Biological Trace Element Research · doi:10.1007/s12011-019-02024-7 · Cited by 58
Luis, G., Rubio, C., Revert, C., Hernández-Espinosa, A. K., González‐Weller, D., Gutiérrez, A. J., & Hardisson, A. (2015) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2014.11.013 · Cited by 58 · cited 4×
“These milk derivatives contain numerous dietary supplements like proteins, vitamins mainly of B12 and B2, and minerals likely Ca, Mg, and Zn which produce a beneficial effect on human health predominantly to balance the intestinal flora and diminish the blood cholesterol level as well as a preventive effect against co…”
BackgroundInfluentialSchenk, E. R., & Almirall, J. R. (2011) · Forensic Science International · doi:10.1016/j.forsciint.2011.11.009 · Cited by 47 · cited 2×
“…of radiofrequency discharge (RF) while in the ICP-MS technique analyte ions are transported through a mass spectrometer where the ions of analyte are separated through the magnetic field according to their mass to charge ratio (m/z) (Thomas 2001; Tyler and Jobin 1995; Schenk and Almirall 2012).”
BackgroundDetermination of Phosphorus in Soil by ICP-OES Using an Improved Standard Addition Method
Yang, J., Bai, J., Liu, M., Chen, Y., Wang, S., & Yang, Q. (2018) · Journal of Analytical Methods in Chemistry · doi:10.1155/2018/1324751 · Cited by 44 · cited 2×
“The presence of phosphorous in the soil is mainly due to the phosphorous cycle in the ecosystem as well as due to the ecology and geology of the soil (Yang et al. 2018).”
BackgroundKlostermeier, A., Engelhard, C., Evers, S., Sperling, M., & Buscher, W. (2005) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b416632a · Cited by 39 · cited 1×
“0 L/min and this gas flow is utilized generally when organic samples are analyzed which reduces the carbon formation over the tip of the injector tube (Klostermeier et al. 2005; Wiederin et al. 1991; Johnson et al. 2004).”
BackgroundPradhan, S. K., & Ambade, B. (2020) · Journal of Analytical Atomic Spectrometry · doi:10.1039/d0ja00190b · Cited by 38 · cited 2×
“The accuracy of the method developed for all lanthanides was checked by analysis of recovery test and the recovery studies were analyzed and the recovery of all lanthanides was found to be in the range of 90–100% (Pradhan and Ambade 2020).”
MethodSheeran, P. S., Daghighi, Y., Yoo, K., Williams, R., Chérin, E., Foster, F. S., & Burns, P. N. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.11.012 · Cited by 37 · cited 2×
“The second type of radio frequency (RF) generators is the free-running generators which operate based on oscillation frequency which depends on two conditions such as electronic components of the generator circuitry as well as plasma discharge conditions (Ghosh et al. 2013; Sheeran et al. 2016).”
BackgroundMartínez, S., Sánchez, R., Lefevre, J., & Torró, J. L. T. (2020) · Journal of Analytical Atomic Spectrometry · doi:10.1039/d0ja00112k · Cited by 20 · cited 1×
“Barium was also found in frying oil as well as used cooking oil (Martinez et al. 2020).”
BackgroundWełna, M., Borkowska-Burnecka, J., & Popko, M. (2015) · Talanta · doi:10.1016/j.talanta.2015.07.058 · Cited by 18 · cited 2×
“In calcium-rich materials like dolomites, Pb estimation was performed by atomic spectrometric techniques such as ICP-OES, AAS, and AFS and can be utilized mainly for the plumbane generation which is a very effective technique for separating Pb from complex matrices but among them, hydride generation (HG) coupled with…”
MethodVallapragada, V. V., Inti, G., & Ramulu, J. S. (2011) · American Journal of Analytical Chemistry · doi:10.4236/ajac.2011.26082 · Cited by 17 · cited 1×
“have successfully carried out in vitro phosphate binding study in Eliphos tablet samples for estimation of free calcium and phosphorous (Vallapragada et al. 2011).”
Background
Cited by
Measuring chloride binding in cementitious materials: A review by RILEM TC 298-EBD
Georget, F., Babaahmadi, A., Machner, A., Mrak, M., Dolenec, S., Xiong, Q. X., Shiju, J., Snoeck, D., Suraneni, P., & Wilson, W. (2025) · Materials and Structures · doi:10.1617/s11527-025-02802-x · Cited by 10
Metadata
- Authors
- Khan, S. R., Sharma, B., Chawla, P. A., & Bhatia, R.
- Venue
- Food Analytical Methods
- Published
- 2021-11-02
- Volume
- 15
- Issue
- 3
- Pages
- 666-688
- ISSN
- 1936-9751 (ISSN-L)
- 1936-976X
- OpenAlex
- W3208930468
- Cited by
- 228
- References
- 31
- FWCI
- 10.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.