Cited by 692Power Systems and Renewable EnergyBattery Modeling and ManagementAdvancements in Battery Materials

The DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.

Applications of Lithium-Ion Batteries in Grid-Scale Energy Storage Systems

Open access
Chen, Tianmei, Jin, Yi, Lv, Hanyu, Yang, Antao, Liu, Meiyi, Chen, Bing, Xie, Ying, Chen, Qiang·2020·Transactions of Tianjin University

Abstract

Abstract In the electrical energy transformation process, the grid-level energy storage system plays an essential role in balancing power generation and utilization. Batteries have considerable potential for application to grid-level energy storage systems because of their rapid response, modularization, and flexible installation. Among several battery technologies, lithium-ion batteries (LIBs) exhibit high energy efficiency, long cycle life, and relatively high energy density. In this perspective, the properties of LIBs, including their operation mechanism, battery design and construction, and advantages and disadvantages, have been analyzed in detail. Moreover, the performance of LIBs applied to grid-level energy storage systems is analyzed in terms of the following grid services: (1) frequency regulation; (2) peak shifting; (3) integration with renewable energy sources; and (4) power management. In addition, the challenges encountered in the application of LIBs are discussed and possible research directions aimed at overcoming these challenges are proposed to provide insight into the development of grid-level energy storage systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s12209-020-00236-w

Cites

74 of 74 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 74 references

Research works printed but not linked: 2

  1. Albright G, Edie J, Al-Hallaj S (2012) A comparison of lead acid to lithium-ion in stationary storage applications. All Cell Technologies LLC, New York
  2. Mukai D, Kobayashi K, Kurahashi T et al (2012) Development of large high-performance lithium-ion batteries for power storage and industrial use. Mitsubishi Heavy Ind Tech Rev 49(1):6

Cited by

Sorted by citations

Metadata

Authors
Chen, T., Jin, Y., Lv, H., Yang, A., Liu, M., Chen, B., Xie, Y., & Chen, Q.
Affiliations
State Grid Corporation of China (China) (CN)
Corresponding author
Chen, Tianmei
Venue
Transactions of Tianjin University
Published
2020-02-08
Volume
26
Issue
3
Pages
208-217
ISSN
  • 1006-4982 (ISSN-L)
  • 1995-8196
OpenAlex
W3005112572
Cited by
692
References
74
Citations by year
2026: 104 · 2025: 142 · 2024: 135 · 2023: 138 · 2022: 83 · 2021: 71 · 2020: 19
FWCI
22.72
Type
journal article
Language
en
Open access
Locations
Transactions of Tianjin University (publishedVersion, cc-by)
Topics
  • Physical Sciences › Energy › Energy Engineering and Power Technology › Power Systems and Renewable Energy
  • Physical Sciences › Engineering › Automotive Engineering › Battery Modeling and Management
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Battery Materials
Keywords
lithium-ion batteries, grid-scale energy storage, frequency regulation, peak shaving, renewable energy integration, power management, battery design, grid services

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review