Fixation of Bovine Pericardium-Based Tissue Biomaterial with Irreversible Chemistry Improves Biochemical and Biomechanical Properties
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Bioprosthetic heart valves (BHVs), derived from glutaraldehyde crosslinked (GLUT) porcine aortic valve leaflets or bovine pericardium (BP), are used to replace defective heart valves. However, valve failure can occur within 12–15 years due to calcification and/or progressive structural degeneration. We present a novel fabrication method that utilizes carbodiimide, neomycin trisulfate, and pentagalloyl glucose crosslinking chemistry (TRI) to better stabilize the extracellular matrix of BP. We demonstrate that TRI-treated BP is more compliant than GLUT-treated BP. GLUT-treated BP exhibited permanent geometric deformation and complete alteration of apparent mechanical properties when subjected to induced static strain. TRI BP, on the other hand, did not exhibit such permanent geometric deformations or significant alterations of apparent mechanical properties. TRI BP also exhibited better resistance to enzymatic degradation in vitro and calcification in vivo when implanted subcutaneously in juvenile rats for up to 30 days.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Perrotta, I., Russo, E., Camastra, C., Filice, G., Di Mizio, G., Colosimo, F., Ricci, P., Tripepi, S., Amorosi, A., Triumbari, F., et al. (2011) · Histopathology · doi:10.1111/j.1365-2559.2011.03977.x · Cited by 77
Cited by
Degeneration of Bioprosthetic Heart Valves: Update 2020
Kostyunin, A. E., Yuzhalin, A. E., Rezvova, M. A., Ovcharenko, E. A., Glushkova, T. V., & Kutikhin, A. G. (2020) · Journal of the American Heart Association · doi:10.1161/jaha.120.018506 · Cited by 347
Saleh, T., Ahmed, E., Yu, L., Hussein, K., Park, K.-M., Lee, Y.-S., Kang, B.-J., Choi, K.-Y., Choi, S., Kang, K.-S., et al. (2018) · Artificial Cells, Nanomedicine, and Biotechnology · doi:10.1080/21691401.2018.1457037 · Cited by 41
“This finding was in agreement with previous studies [3,5,42].”
BackgroundResultMammalian Pericardium‐Based Bioprosthetic Materials in Xenotransplantation and Tissue Engineering
Grebenik, E. A., Gafarova, E. R., Istranov, L. P., Istranova, E. V., Ma, X., Xu, J., Guo, W., Atala, A., & Timashev, P. S. (2020) · Biotechnology Journal · doi:10.1002/biot.201900334 · Cited by 30
Walker, S., Dittfeld, C., Jakob, A., Schönfelder, J., König, U., & Tugtekin, S.-M. (2022) · The Thoracic and Cardiovascular Surgeon · doi:10.1055/s-0040-1705100 · Cited by 11
Metadata
- Authors
- Tam, H., Zhang, W., Infante, D., Parchment, N., Sacks, M., & Vyavahare, N.
- Venue
- Journal of Cardiovascular Translational Research
- Published
- 2017-02-17
- Volume
- 10
- Issue
- 2
- Pages
- 194-205
- ISSN
- 1937-5387 (ISSN-L)
- 1937-5395
- OpenAlex
- W2589082900
- Cited by
- 69
- References
- 1
- FWCI
- 8.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fixation of Bovine Pericardium-Based Tissue Biomaterial with Irreversible Chemistry Improves Biochemical and Biomechanical Properties. https://app.cochat.ai/papers/10.1007/s12265-017-9733-5
- The paper
- Tam, H., Zhang, W., Infante, D., Parchment, N., Sacks, M., & Vyavahare, N. (2017). Fixation of Bovine Pericardium-Based Tissue Biomaterial with Irreversible Chemistry Improves Biochemical and Biomechanical Properties. Journal of Cardiovascular Translational Research. https://doi.org/10.1007/s12265-017-9733-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.