The DOI matches its Crossref record.
Highly-sensitive multiplexed in vivo imaging using pegylated upconversion nanoparticles
Open accessAbstract
Lanthanide-based upconversion nanoparticles (UCNPs) have been widely explored in various fields, including optical imaging, in recent years. Although earlier work has shown that UCNPs with different lanthanide (Ln3+) dopants exhibit various colors, multicolor-especially in vivo multiplexed biomedical imaging-using UCNPs has rarely been reported. In this work, we synthesize a series of UCNPs with different emission colors and functionalize them with an amphiphilic polymer to confer water solubility. Multicolor in vivo upconversion luminescence (UCL) imaging is demonstrated by imaging subcutaneously injected UCNPs and applied in multiplexed in vivo lymph node mapping. We also use UCNPs for multicolor cancer cell labeling and realize in vivo cell tracking by UCL imaging. Moreover, for the first time we compare the in vivo imaging sensitivity of quantum dot (QD)-based fluorescence imaging and UCNP-based UCL imaging side by side, and find the in vivo detection limit of UCNPs to be at least one order of magnitude lower than that of QDs in our current non-optimized imaging system. Our data suggest that, by virtue of their unique optical properties, UCNPs have great potential for use in highly-sensitive multiplexed biomedical imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cheng, L., Yang, K., Li, Y., Zeng, X., Shao, M., Lee, S.-T., & Liu, Z. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.11.069 · Cited by 386
Self-citationLiu, K., Liu, X., Zeng, Q., Zhang, Y., Tu, L., Liu, T., Kong, X., Wang, Y., Cao, F., Lambrechts, S. A. G., et al. (2012) · ACS Nano · doi:10.1021/nn300436b · Cited by 382
Upconversion-based photodynamic cancer therapy
Liu, Y., Meng, X., & Bu, W. (2019) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.09.006 · Cited by 319
Xu, H., Cheng, L., Wang, C., Ma, X., Li, Y., & Liu, Z. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.08.053 · Cited by 301
Metadata
- Authors
- Cheng, L., Yang, K., Zhang, S., Shao, M., Lee, S., & Liu, Z.
- Venue
- Nano Research
- Publisher
- Tsinghua University Press
- Published
- 2010-09-21
- Volume
- 3
- Issue
- 10
- Pages
- 722-732
- ISSN
- 1998-0000 (ISSN-L)
- 1998-0124
- OpenAlex
- W2016146050
- Cited by
- 303
- References
- 0
- FWCI
- 13.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly-sensitive multiplexed in vivo imaging using pegylated upconversion nanoparticles. https://app.cochat.ai/papers/10.1007/s12274-010-0036-2
- The paper
- Cheng, L., Yang, K., Zhang, S., Shao, M., Lee, S., & Liu, Z. (2010). Highly-sensitive multiplexed in vivo imaging using pegylated upconversion nanoparticles. Nano Research. https://doi.org/10.1007/s12274-010-0036-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.