Dopant-controlled synthesis of water-soluble hexagonal NaYF4 nanorods with efficient upconversion fluorescence for multicolor bioimaging
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A novel strategy is proposed to directly synthesize water-soluble hexagonal NaYF4 nanorods by doping rare-earth ions with large ionic radius (such as La3+, Ce3+, Pr3+, Nd3+, Sm3+, Eu3+, and Gd3+), and the dopantcontrolled growth mechanism is studied. Based on the doping effect, we fabricated water-soluble hexagonal NaYF4:(Yb,Er)/La and NaYF4:(Yb,Er)/Ce nanorods, which exhibited much brighter upconversion fluorescence than the corresponding cubic forms. The sizes of the nanorods can be adjusted over a broad range by changing the dopant concentration and reaction time. Furthermore, we successfully demonstrated a novel depth-sensitive multicolor bioimaging for in vivo use by employing the as-synthesized NaYF4:(Yb,Er)/La nanorods as probes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shape control of CdSe nanocrystals
Peng, X., Manna, L., Yang, W., Wickham, J., Scher, E., Kadavanich, A., & Alivisatos, A. P. (2000) · Nature · doi:10.1038/35003535 · Cited by 4,487
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265 · cited 1×
“It is interesting that the observed output color is depth-sensitive in the leg tissues because the emitted red light has much deeper tissue penetration than the green light [51].”
Background
Cited by
Near-infrared fluorophores for biomedical imaging
Hong, G., Antaris, A. L., & Dai, H. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0010 · Cited by 2,985
Upconversion Nanoparticles: Design, Nanochemistry, and Applications in Theranostics
Chen, G., Qiu, H., Prasad, P. N., & Chen, X. (2014) · Chemical Reviews · doi:10.1021/cr400425h · Cited by 2,699
Haase, M., & Schäfer, H. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201005159 · Cited by 2,503
Upconversion nanophosphors for small-animal imaging
Zhou, J., Liu, Z., & Li, F. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15187h · Cited by 1,581
Upconversion nanoparticles in biological labeling, imaging, and therapy
Wang, F., Banerjee, D., Liu, Y., Chen, X., & Liu, X. (2010) · The Analyst · doi:10.1039/c0an00144a · Cited by 1,409
Wang, F., Wang, J., & Liu, X. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.201003959 · Cited by 954
Tian, G., Gu, Z., Zhou, L., Yin, W., Liu, X., Yan, L., Jin, S., Ren, W., Xing, G., Li, S., et al. (2012) · Advanced Materials · doi:10.1002/adma.201104741 · Cited by 827
Rare earth fluoride nano-/microcrystals: synthesis, surface modification and application
Li, C., & Lin, J. (2010) · Journal of Materials Chemistry · doi:10.1039/c0jm00031k · Cited by 675
Cheng, L., Yang, K., Li, Y., Chen, J., Wang, C., Shao, M., Lee, S., & Liu, Z. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201101447 · Cited by 650
Self-citationGu, Z., Yan, L., Tian, G., Li, S., Chai, Z., & Zhao, Y. (2013) · Advanced Materials · doi:10.1002/adma.201301197 · Cited by 491
Sedlmeier, A., & Gorris, H. H. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00186a · Cited by 482
Yang, Y., Shao, Q., Deng, R., Wang, C., Teng, X., Cheng, K., Cheng, Z., Huang, L., Liu, Z., Liu, X., et al. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201107919 · Cited by 467
Upconverting luminescent nanoparticles for use in bioconjugation and bioimaging
Mader, H. S., Kele, P., Saleh, S. M., & Wolfbeis, O. S. (2010) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2010.08.014 · Cited by 446
Gorris, H. H., & Wolfbeis, O. S. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201208196 · Cited by 436
Lanthanide upconversion nanoparticles and applications in bioassays and bioimaging: A review
DaCosta, M. V., Doughan, S., Han, Y., & Krull, U. J. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.04.030 · Cited by 404
Lanthanide-doped up-converting nanoparticles: Merits and challenges
Gnach, A., & Bednarkiewicz, A. (2012) · Nano Today · doi:10.1016/j.nantod.2012.10.006 · Cited by 393
Wang, Y., Wang, H., Liu, D., Song, S., Wang, X., & Zhang, H. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.06.045 · Cited by 373
Sun, L.-D., Wang, Y.-F., & Yan, C.-H. (2014) · Accounts of Chemical Research · doi:10.1021/ar400218t · Cited by 363
Cheng, L., Wang, C., & Liu, Z. (2013) · Nanoscale · doi:10.1039/c2nr32311g · Cited by 359
Upconverting and NIR emitting rare earth based nanostructures for NIR-bioimaging
Hemmer, E., Venkatachalam, N., Hyodo, H., Hattori, A., Ebina, Y., Kishimoto, H., & Soga, K. (2013) · Nanoscale · doi:10.1039/c3nr02286b · Cited by 343
Lin, M., Zhao, Y., Wang, S., Liu, M., Duan, Z., Chen, Y., Li, F., Xu, F., & Lu, T. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2012.04.009 · Cited by 325
Tian, G., Ren, W., Yan, L., Jian, S., Gu, Z., Zhou, L., Jin, S., Yin, W., Li, S., & Zhao, Y. (2013) · Small · doi:10.1002/smll.201201437 · Cited by 193
Metadata
- Authors
- Yu, X., Li, M., Xie, M., Chen, L., Li, Y., & Wang, Q.
- Venue
- Nano Research
- Publisher
- Tsinghua University Press
- Published
- 2010-01
- Volume
- 3
- Issue
- 1
- Pages
- 51-60
- ISSN
- 1998-0000 (ISSN-L)
- 1998-0124
- OpenAlex
- W1982200858
- Cited by
- 215
- References
- 2
- FWCI
- 13.28
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.