The relationship between exercise intensity and the sweat lactate excretion rate
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to determine the effect of increases in exercise intensity on the sweat lactate concentration and lactate excretion rate. Eight healthy male volunteers complete a 90-min exercise bout of treadmill walking in a 35 degrees C and 40% relative humidity environmental chamber. During the exercise trial, the subjects performed three 30-min ordered exercise bouts at 60, 70, and 80% of their age-predicted maximum heart rate (HR(max)), with 10 min of rest outside the chamber between bouts. Sweat rate was measured volumetrically during each of the three exercise bouts on the flexor surface of the proximal half of the right forearm. Sweat lactate concentration ([lactate](sweat)) was measured in each sample and multiplied by the forearm sweat rate to calculate the lactate excretion rate (LER). There was a significant (P < 0.05) decrease in the [lactate](sweat) at the 70 and 80% HR(max) exercise intensities compared to the 60% HR(max) exercise intensity. Conversely, the LER increased significantly at the highest two exercise intensities compared to the 60% HR(max) exercise intensity. Such data suggest that increases in exercise intensity require an increase in lactate production, as measured by the LER. Furthermore, the decreased [lactate](sweat) at the higher exercise intensities is most likely the result of increased sweat production causing a dilution effect on the [lactate](sweat), thus limiting its ability to accurately indicate the metabolic activity of the sweat gland.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This observation can be attributed to the increase in both lactate excretion rate and sweat rate upon the increase of the workload31.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [31]
In the citing paper
“Studies have found a direct relation between sweating rate and lactate excretion rate in terms of mmol/cm2/min”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Buono et al. 2010
In the citing paper
“There seems to be an inverse relation between flow rate and lactate concentration such that sweat lactate concentration decreases as sweating rate increases, possibly as a result of dilution”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Buono et al. 2010
In the citing paper
“This is consistent with the notion that sweat lactate concentrations become diluted with higher volumes of sweat (Buono et al. 2010).”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Buono et al. 2010
In the citing paper
“These and other studies (Buono et al. 2010) illustrate the lack of support for using sweat lactate or ammonia as biomarker for exercise intensity.”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Buono et al. 2010
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robinson, S., & Robinson, A. H. (1954) · Physiological Reviews · doi:10.1152/physrev.1954.34.2.202 · Cited by 514
Variations in Regional Sweat Composition in Normal Human Males
Patterson, M. J., Galloway, S. D. R., & Nimmo, M. A. (2000) · Experimental Physiology · doi:10.1111/j.1469-445x.2000.02058.x · Cited by 438
The physiology, pharmacology, and biochemistry of the eccrine sweat gland
Sato, K. (1977) · Reviews of Physiology, Biochemistry and Pharmacology · doi:10.1007/bfb0037089 · Cited by 384 · cited 3×
“In isolated human forearm sweat glands, the metabolism of glucose appears to consist equally of both oxidative phosphorylation in the abundant mitochondria located in the clear cells of the secretory coil and substrate-level phosphorylation via glycolysis [18, 19, 22].”
BackgroundEffect of hyperosmolality on control of blood flow and sweating
Fortney, S. M., Wenger, C. B., Bove, J. R., & Nadel, E. R. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.57.6.1688 · Cited by 194 · cited 1×
“We hypothesize that this was the result of exercise-induced hyperosmolality which has previously been shown to reduce thermoregulatory sweating [23].”
BackgroundQuinton, P. M. (1983) · Annual Review of Medicine · doi:10.1146/annurev.me.34.020183.002241 · Cited by 103 · cited 2×
“In isolated human forearm sweat glands, the metabolism of glucose appears to consist equally of both oxidative phosphorylation in the abundant mitochondria located in the clear cells of the secretory coil and substrate-level phosphorylation via glycolysis [18, 19, 22].”
BackgroundSweat lactate response between males with high and low aerobic fitness
Green, J. M., Pritchett, R. C., Crews, T. R., McLester, J. R., & Tucker, D. C. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0968-2 · Cited by 70
Effect of age and gender on sweat lactate and ammonia concentrations during exercise in the heat
Meyer, F., Laitano, O., Bar-Or, O., McDougall, D., & Heigenhauser, G. J. F. (2007) · Brazilian Journal of Medical and Biological Research · doi:10.1590/s0100-879x2006005000044 · Cited by 70
Quinton, P. M., & Tormey, J. M. (1976) · The Journal of Membrane Biology · doi:10.1007/bf01868972 · Cited by 69 · cited 1×
“Both of these steps are energy dependent and driven by the ouabainsensitive Na- K ATPase located in the basolateral membrane of both the secretory coil and the distal reabsorption duct [20].”
BackgroundQuinton, P. M. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00581513 · Cited by 65 · cited 1×
“This is supported by the fact that ouabain blocks sweat secretion and sodium reabsorption [8, 21].”
BackgroundMetabolic studies of isolated human eccrine sweat glands
Wolfe, S., Cage, G., Epstein, M., Tice, L., Miller, H., & Gordon, R. S. (1970) · Journal of Clinical Investigation · doi:10.1172/jci106407 · Cited by 64 · cited 3×
“It has been previously shown that blood glucose is the major substrate for energy production by the human eccrine sweat gland [5, 7, 8].”
Background
Cited by
Items 101–128 of 128
Impact of Active Break with Guided Dance in University Classes
Lobach, Y., Ramos, Ó. R., Romero-Ramos, N., Niznikowski, Т., & Fernández-Rodríguez, E. (2023) · Polish Journal of Sport and Tourism · doi:10.2478/pjst-2023-0025 · Cited by 7
Kishi, R., Nishitani, S., Kudo, H., & Sakata, T. (2024) · ACS Omega · doi:10.1021/acsomega.4c06671 · Cited by 2
Perceiving exertion in others: From interoception to exteroception
Liu, M., Dudarev, V., de Brouwer, A. J., & Enns, J. T. (2025) · Psychonomic Bulletin & Review · doi:10.3758/s13423-025-02753-y · Cited by 2
“Sweat rates increase with higher exercise intensity in both aerobic (Buono et al., 2010) and resistance exercise settings (Kondo et al., 2000), making them potentially available as a visual signal about exertion in others.”
Recent Advances in Electrospun Nanofiber-Based Wearable Sweat Sensors
Mei, X., Liu, X., Peng, X., Xiong, W., Xiao, S., Leng, X., Cheng, L., Li, Y., & Wang, B. (2026) · ACS Sensors · doi:10.1021/acssensors.6c00132 · Cited by 2
Acute Effect of Passive Hyperthermia on Lactate Concentrations
Siquier-Coll, J., Flores, J. M., Pérez, F. J. G., Bartolomé, I., Maynar-Mariño, M., & Toro-Román, V. (2024) · Applied Sciences · doi:10.3390/app14072895 · Cited by 2
Integrated flexible sensors with amplifier circuit for pH and temperature analysis
Liu, G., Shu, X., Li, J., Xu, T., Sui, C., Zhang, S., & Yang, R. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.117024 · Cited by 2
Wax, B., Hilton, L., Vickers, B., Gilliland, K. J., & Conrad, M. (2013) · Journal of Dietary Supplements · doi:10.3109/19390211.2012.758216 · Cited by 2
Flow injection system for real-time monitoring of lactic acid at the outer surface of the skin
Kudo, H., Enomoto, K., & Jingushi, Y. (2016) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2016.7758199 · Cited by 2
“It is known that sweat LA during an exercise depends on the aerobic metabolic capacity [14] and elevates 315 folds under the high intensity exercise that requests anaerobic metabolism [15-19], hence the results were consistent with previously reported papers.”
ResultOkawara, H., Sawada, T., Nakashima, D., Maeda, Y., Minoji, S., Morisue, T., Katsumata, Y., Matsumoto, M., Nakamura, M., & Nagura, T. (2022) · Sensors · doi:10.3390/s22155473 · Cited by 4
Yamagata, T., & Shigemori, Y. (2023) · Gazzetta Medica Italiana Archivio per le Scienze Mediche · doi:10.23736/s0393-3660.22.04780-5 · Cited by 2
Dielectric-response enabled continuous multi-analyte monitoring in sweat with high specificity
Wang, J., Liu, C., Sun, A., Ju, F., Du, X., Ding, Y., Wang, J., & Wang, L. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.115478 · Cited by 1
Zhang, Y., Zhong, B., Yuan, Y., Xu, K., Yu, Y., Lou, Z., & Wang, L. (2026) · Advanced Materials Technologies · doi:10.1002/admt.202502662 · Cited by 3
Lee, J., Moon, J.-H., kim, Y., Kim, H., Kim, E., Lee, H., Yoon, S., Chon, S., Lee, Y., & Park, J. (2026) · Scientific Reports · doi:10.1038/s41598-026-47148-8 · Cited by 3
“CBT demonstrated a moderate positive association with BLa ( r = 0.563, P 0.001), aligning with previous findings that elevated internal temperature parallels increased lactate accumulation owing to enhanced glycolytic flux under thermal load 13,17 .”
InfluentialHeck, H. (2022) · Springer eBooks · doi:10.1007/978-3-662-59835-1_18 · Cited by 1
Development of a Non-enzymatic, Non-invasive Sensor for Detection of Lactate in Sweat
ljungh, A. (2018) · Chalmers Publication Library (Chalmers University of Technology)
Development of electrochemical biosensors and sensors for the determination of interest analytes
Cunha‐Silva, H. (2019) · Repositorio Institucional de la Universidad de Burgos (University of Burgos) · doi:10.36443/10259/5391
Merante, F. (2020) · Biomedical Journal of Scientific & Technical Research · doi:10.26717/bjstr.2020.25.004169
“18949 blood [17,26-28]; and baseline lactate concentrations across the skin surface do not vary [21].”
BackgroundGoto, Y., Suzuki, Y., Morisawa, K., Hosoyama, A., Taira, Y., & Kudo, H. (2021) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/1192/1/012006
Cáparra, parada y fonda en la Vía de la Plata
Uceta, A. D. (2003) · La Aventura de la historia
Análisis de la estructura del juego y parámetros morfológicos y fisiológicos en bádminton
Vicen, P. A. (2015) · UPM Digital Archive (Technical University of Madrid) · doi:10.20868/upm.thesis.35047 · Cited by 5
Wang, X., Shi, H., Xu, H., Qin, X., Yuan, Y., Deng, F., Wang, Z., Li, Z., Li, L., Lou, Z., et al. (2026) · Materials Today Electronics · doi:10.1016/j.mtelec.2026.100212
Adaptive amphiphobic Janus fabric with pH-triggered one-way transport ability
Chi, H., Cao, H., Xu, Z., & Zhao, Y. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.176020
Conde, D., Ibarra-Mejía, G., Gomez, M., & Gurovich, A. N. (2026) · Biology · doi:10.3390/biology15130998
“In the field of exercise science, lactate is often used as an indicator of exercise intensity, as it correlates with changes in exercise intensity [36,37].”
Laser-written high-entropy metal–oxy patch for non-enzymatic lactate–pH sweat sensing
Fan, L., Wang, J., Xin, Y., & Zhang, Z. D. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.119028
Lin, W., Xue, T., Zhou, J., Luo, C., Zhou, Z., Zhang, X., & Zhu, G. (2026) · Talanta · doi:10.1016/j.talanta.2026.130335
Science‐in‐brief: Wearable sweat lactate sensors in equine athletes: Science fiction or reality?
Decloedt, A., Gijssel, M., Cuartero, M., & Crespo, G. A. (2026) · Equine Veterinary Journal · doi:10.1002/evj.70206
Meng, L., Yoshida, T., Oshima, S., Wang, H., Fujii, N., & Amano, T. (2026) · European Journal of Applied Physiology · doi:10.1007/s00421-026-06407-2
Xue, T., Lin, W., Zhou, J., Luo, C., Li, B., Zhang, X., Chen, C.-J., Liu, J., & Zhu, G. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01436-5
“Lactate levels serve as a key indicator for evaluating athletes ’ aerobic and anaerobic capacities, offering valuable insights for optimizing training intensity and recovery strategies 11,17 – 19 .”
Metadata
- Authors
- Buono, M. J., Lee, N. V. L., & Miller, P. W.
- Affiliations
- San Diego State University (US)
- Corresponding author
- Buono, Michael J.
- ORCID
- Buono, Michael J.
- Venue
- The Journal of Physiological Sciences
- Publisher
- Elsevier BV
- Published
- 2010-03
- Volume
- 60
- Issue
- 2
- Pages
- 103-107
- ISSN
- 1880-6546 (ISSN-L)
- PMC
- PMC10717057
- OpenAlex
- W1994964334
- Cited by
- 128
- References
- 23
- Citations by year
- 2026: 12 · 2025: 11 · 2024: 13 · 2023: 13 · 2022: 10 · 2021: 14 · 2020: 12 · 2019: 7 · 2018: 7 · 2017: 9 · 2016: 6 · 2015: 4 · 2014: 1 · 2013: 4 · 2012: 4
- FWCI
- 0.88
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc-nd
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor, 5420 d)
- Locations
- The Journal of Physiological Sciences (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Keywords
- sweat lactate, exercise intensity, sweat rate, treadmill walking, heat stress, lactic acid production, age-predicted maximum heart rate
- MeSH terms
- Adult, Physical Exertion, Humans, Male, Models, Biological, Statistics as Topic, Sweat, Sweating, Exercise, Lactic Acid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.