The relationship between exercise intensity and the sweat lactate excretion rate
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to determine the effect of increases in exercise intensity on the sweat lactate concentration and lactate excretion rate. Eight healthy male volunteers complete a 90-min exercise bout of treadmill walking in a 35 degrees C and 40% relative humidity environmental chamber. During the exercise trial, the subjects performed three 30-min ordered exercise bouts at 60, 70, and 80% of their age-predicted maximum heart rate (HR(max)), with 10 min of rest outside the chamber between bouts. Sweat rate was measured volumetrically during each of the three exercise bouts on the flexor surface of the proximal half of the right forearm. Sweat lactate concentration ([lactate](sweat)) was measured in each sample and multiplied by the forearm sweat rate to calculate the lactate excretion rate (LER). There was a significant (P < 0.05) decrease in the [lactate](sweat) at the 70 and 80% HR(max) exercise intensities compared to the 60% HR(max) exercise intensity. Conversely, the LER increased significantly at the highest two exercise intensities compared to the 60% HR(max) exercise intensity. Such data suggest that increases in exercise intensity require an increase in lactate production, as measured by the LER. Furthermore, the decreased [lactate](sweat) at the higher exercise intensities is most likely the result of increased sweat production causing a dilution effect on the [lactate](sweat), thus limiting its ability to accurately indicate the metabolic activity of the sweat gland.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This observation can be attributed to the increase in both lactate excretion rate and sweat rate upon the increase of the workload31.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [31]
In the citing paper
“Studies have found a direct relation between sweating rate and lactate excretion rate in terms of mmol/cm2/min”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Buono et al. 2010
In the citing paper
“There seems to be an inverse relation between flow rate and lactate concentration such that sweat lactate concentration decreases as sweating rate increases, possibly as a result of dilution”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Buono et al. 2010
In the citing paper
“This is consistent with the notion that sweat lactate concentrations become diluted with higher volumes of sweat (Buono et al. 2010).”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Buono et al. 2010
In the citing paper
“These and other studies (Buono et al. 2010) illustrate the lack of support for using sweat lactate or ammonia as biomarker for exercise intensity.”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Buono et al. 2010
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robinson, S., & Robinson, A. H. (1954) · Physiological Reviews · doi:10.1152/physrev.1954.34.2.202 · Cited by 514
Variations in Regional Sweat Composition in Normal Human Males
Patterson, M. J., Galloway, S. D. R., & Nimmo, M. A. (2000) · Experimental Physiology · doi:10.1111/j.1469-445x.2000.02058.x · Cited by 438
The physiology, pharmacology, and biochemistry of the eccrine sweat gland
Sato, K. (1977) · Reviews of Physiology, Biochemistry and Pharmacology · doi:10.1007/bfb0037089 · Cited by 384 · cited 3×
“In isolated human forearm sweat glands, the metabolism of glucose appears to consist equally of both oxidative phosphorylation in the abundant mitochondria located in the clear cells of the secretory coil and substrate-level phosphorylation via glycolysis [18, 19, 22].”
BackgroundEffect of hyperosmolality on control of blood flow and sweating
Fortney, S. M., Wenger, C. B., Bove, J. R., & Nadel, E. R. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.57.6.1688 · Cited by 194 · cited 1×
“We hypothesize that this was the result of exercise-induced hyperosmolality which has previously been shown to reduce thermoregulatory sweating [23].”
BackgroundQuinton, P. M. (1983) · Annual Review of Medicine · doi:10.1146/annurev.me.34.020183.002241 · Cited by 103 · cited 2×
“In isolated human forearm sweat glands, the metabolism of glucose appears to consist equally of both oxidative phosphorylation in the abundant mitochondria located in the clear cells of the secretory coil and substrate-level phosphorylation via glycolysis [18, 19, 22].”
BackgroundSweat lactate response between males with high and low aerobic fitness
Green, J. M., Pritchett, R. C., Crews, T. R., McLester, J. R., & Tucker, D. C. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0968-2 · Cited by 70
Effect of age and gender on sweat lactate and ammonia concentrations during exercise in the heat
Meyer, F., Laitano, O., Bar-Or, O., McDougall, D., & Heigenhauser, G. J. F. (2007) · Brazilian Journal of Medical and Biological Research · doi:10.1590/s0100-879x2006005000044 · Cited by 70
Quinton, P. M., & Tormey, J. M. (1976) · The Journal of Membrane Biology · doi:10.1007/bf01868972 · Cited by 69 · cited 1×
“Both of these steps are energy dependent and driven by the ouabainsensitive Na- K ATPase located in the basolateral membrane of both the secretory coil and the distal reabsorption duct [20].”
BackgroundQuinton, P. M. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00581513 · Cited by 65 · cited 1×
“This is supported by the fact that ouabain blocks sweat secretion and sodium reabsorption [8, 21].”
BackgroundMetabolic studies of isolated human eccrine sweat glands
Wolfe, S., Cage, G., Epstein, M., Tice, L., Miller, H., & Gordon, R. S. (1970) · Journal of Clinical Investigation · doi:10.1172/jci106407 · Cited by 64 · cited 3×
“It has been previously shown that blood glucose is the major substrate for energy production by the human eccrine sweat gland [5, 7, 8].”
Background
Cited by
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
“This observation can be attributed to the increase in both lactate excretion rate and sweat rate upon the increase of the workload 31 .”
BackgroundElectrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
Physiology of sweat gland function: The roles of sweating and sweat composition in human health
Baker, L. B. (2019) · Temperature · doi:10.1080/23328940.2019.1632145 · Cited by 732
“Accordingly, sweat lactate concentration decreases with increasing exercise intensity [161,162].”
BackgroundSkin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
A MXene‐Based Wearable Biosensor System for High‐Performance In Vitro Perspiration Analysis
Lei, Y., Zhao, W., Zhang, Y., Jiang, Q., He, J., Baeumner, A. J., Wolfbeis, O. S., Wang, Z. L., Salama, K. N., & Alshareef, H. N. (2019) · Small · doi:10.1002/smll.201901190 · Cited by 441
A wearable multisensing patch for continuous sweat monitoring
Anastasova, S., Crewther, B., Bembnowicz, P., Curto, V., Ip, H. M., Rosa, B., & Yang, G.-Z. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.038 · Cited by 443
“Lactate concentrations also varied between subjects, which is probably related to differences in lactate excretion and sweat rates with increasing workloads (Buono et al. 2010).”
BackgroundSkin-interfaced systems for sweat collection and analytics
Choi, J., Ghaffari, R., Baker, L. B., & Rogers, J. A. (2018) · Science Advances · doi:10.1126/sciadv.aar3921 · Cited by 433
Bandodkar, A. J., You, J.-M., Kim, N.-H., Gu, Y., Kumar, R., Mohan, A. M. V., Kurniawan, J., Imani, S., Nakagawa, T., Parish, B., et al. (2017) · Energy & Environmental Science · doi:10.1039/c7ee00865a · Cited by 412
A physicochemical-sensing electronic skin for stress response monitoring
Xu, C., Song, Y., Sempionatto, J. R., Solomon, S. A., Yu, Y., Nyein, H. Y. Y., Tay, R. Y., Li, J., Heng, W., Min, J., et al. (2024) · Nature Electronics · doi:10.1038/s41928-023-01116-6 · Cited by 399
“During vigorous exercise, profound activation of the HPA axis led to dramatic changes of all physiological signals as well as sweat metabolites and electrolytes (for example, Na + ), in agreement with previous studies on exercise-induced stress response 42,52 .”
ResultYin, L., Cao, M., Kim, K. N., Lin, M., Moon, J.-M., Sempionatto, J. R., Yu, J., Liu, R., Wicker, C., Trifonov, A., et al. (2022) · Nature Electronics · doi:10.1038/s41928-022-00843-6 · Cited by 358
Physiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367
Epidermal Biofuel Cells: Energy Harvesting from Human Perspiration
Jia, W., Valdés‐Ramírez, G., Bandodkar, A. J., Windmiller, J. R., & Wang, J. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201302922 · Cited by 324
Tattoo‐Based Wearable Electrochemical Devices: A Review
Bandodkar, A. J., Jia, W., & Wang, J. (2015) · Electroanalysis · doi:10.1002/elan.201400537 · Cited by 312
Lactate in human sweat: a critical review of research to the present day
Derbyshire, P. J., Barr, H., Davis, F., & Higson, S. P. J. (2012) · The Journal of Physiological Sciences · doi:10.1007/s12576-012-0213-z · Cited by 280
“However, the overwhelming majority of the literature indicates that that blood and sweat lactate concentration are independent of one another since lactate within sweat is entirely a by-product of sweat gland metabolism, and evidence from a wide variety of studies can be used to support this view [8, 21, 40, 45, 46].”
BackgroundResultArdalan, S., Hosseinifard, M., Vosough, M., & Golmohammadi, H. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112450 · Cited by 195
Wang, R., Zhai, Q., An, T., Gong, S., & Cheng, W. (2021) · Talanta · doi:10.1016/j.talanta.2020.121484 · Cited by 193
A fingertip-wearable microgrid system for autonomous energy management and metabolic monitoring
Ding, S., Saha, T., Yin, L., Liu, R., Khan, M. I., Chang, A.-Y., Lee, H., Zhao, H., Liu, Y., Nazemi, A. S., et al. (2024) · Nature Electronics · doi:10.1038/s41928-024-01236-7 · Cited by 168
“The performance of a single BFC was tested using linear scan voltammetry (LSV) at different lactate concentrations (from 5 to 35 mM), which are the typical physiological levels found in sweat 19,42–44 .”
Cactus‐Spine‐Inspired Sweat‐Collecting Patch for Fast and Continuous Monitoring of Sweat
Son, J., Bae, G. Y., Lee, S., Lee, G., Kim, S. W., Kim, D., Chung, S., & Cho, K. (2021) · Advanced Materials · doi:10.1002/adma.202102740 · Cited by 164
Zhong, B., Jiang, K., Wang, L., & Shen, G. (2022) · Advanced Science · doi:10.1002/advs.202103257 · Cited by 164
Han, W., He, H., Zhang, L., Dong, C., Zeng, H., Dai, Y., Xing, L., Zhang, Y., & Xue, X. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b07990 · Cited by 149
Choi, J., Xue, Y., Xia, W., Ray, T. R., Reeder, J. T., Bandodkar, A. J., Kang, D., Xu, S., Huang, Y., & Rogers, J. A. (2017) · Lab on a Chip · doi:10.1039/c7lc00525c · Cited by 146
Recent Progress in Wearable Biosensors: From Healthcare Monitoring to Sports Analytics
Ye, S., Feng, S., Huang, L. J., & Bian, S. (2020) · Biosensors · doi:10.3390/bios10120205 · Cited by 163
A wearable freestanding electrochemical sensing system
Zhao, Y., Wang, B., Hojaiji, H., Wang, Z., Lin, S., Yeung, C. J., Lin, H., Nguyen, P., Chiu, K., Salahi, K., et al. (2020) · Science Advances · doi:10.1126/sciadv.aaz0007 · Cited by 150
Can Wearable Sweat Lactate Sensors Contribute to Sports Physiology?
Hoovels, K. V., Xuan, X., Cuartero, M., Gijssel, M., Swarén, M., & Crespo, G. A. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01403 · Cited by 143
A thread-based wearable sweat nanobiosensor
Zhao, C., Li, X., Wu, Q., & Liu, X. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113270 · Cited by 125
Biagi, S., Ghimenti, S., Onor, M., & Bramanti, E. (2012) · Biomedical Chromatography · doi:10.1002/bmc.2713 · Cited by 110
“Furthermore, lactate values during exercise may vary owing to sex, age, body mass index, muscle mass percentage and composition, and sweating rate (Buono et al., 2010).”
BackgroundKomkova, M. A., Eliseev, A. A., Poyarkov, A. A., Daboss, E. V., Evdokimov, P. V., Eliseev, A. A., & Karyakin, A. A. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.113970 · Cited by 116
Poletti, F., Zanfrognini, B., Favaretto, L., Quintano, V., Sun, J., Treossi, E., Melucci, M., Palermo, V., & Zanardi, C. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.130253 · Cited by 106
Printed, Flexible Lactate Sensors: Design Considerations Before Performing On-Body Measurements
Payne, M. E., Zamarayeva, A. M., Pister, V. I., Yamamoto, N. A. D., & Arias, A. C. (2019) · Scientific Reports · doi:10.1038/s41598-019-49689-7 · Cited by 106
Wearable physiological systems and technologies for metabolic monitoring
Gao, W., Brooks, G. A., & Klonoff, D. C. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00407.2017 · Cited by 91
Wearable Osmotic-Capillary Patch for Prolonged Sweat Harvesting and Sensing
Saha, T., Fang, J., Mukherjee, S., Dickey, M. D., & Velev, O. D. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c22730 · Cited by 89
Klous, L., de Ruiter, C. J., Scherrer, S., Gerrett, N., & Daanen, H. A. M. (2021) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04562-8 · Cited by 86
“, lower lactate concentrations once LSR gets higher) (Buono et al. 2010).”
BackgroundGarland, N. T., Schmieder, J., Johnson, Z. T., Hjort, R. G., Chen, B., Andersen, C., Sanborn, D., Kjeldgaard, G., Pola, C. C., Li, J., et al. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c04665 · Cited by 90
Wearable device for continuous sweat lactate monitoring in sports: a narrative review
Yang, G., Hong, J., & Park, S.-B. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1376801 · Cited by 101
“Monitoring lactate levels is especially signi fi cant, as it provides insights into an athlete ’ s aerobic and anaerobic capacities that provide valuable insights for developing tailored training and recovery strategies (Goodwin et al., 2007; Buono et al., 2010; Casado et al., 2022).”
BackgroundVaquer, A., Barón, E., & de la Rica, R. (2021) · ACS Sensors · doi:10.1021/acssensors.0c01980 · Cited by 75
A novel device for detecting anaerobic threshold using sweat lactate during exercise
Seki, Y., Nakashima, D., Shiraishi, Y., Ryuzaki, T., Ikura, H., Miura, K., Suzuki, M., Watanabe, T., Nagura, T., Matsumato, M., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-84381-9 · Cited by 86
Potentiometric sensor for non invasive lactate determination in human sweat
Onor, M., Gufoni, S., Lomonaco, T., Ghimenti, S., Salvo, P., Sorrentino, F., & Bramanti, E. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.07.050 · Cited by 73
Analysis of Dehydration and Strength in Elite Badminton Players
Abián-Vicén, J., Del Coso, J., González-Millán, C., Salinero, J. J., & Abián, P. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037821 · Cited by 68
“will be mainly influenced by the intensity of effort [11].”
BackgroundPérez, D., & Orozco, J. (2022) · Microchimica Acta · doi:10.1007/s00604-022-05228-2 · Cited by 72
“Analytes like lactate undergo increased production and excretion rate at highly intensive exercise, but its concentration in the total produced sweat decreases, probably because of a dilutional effect [36].”
BackgroundCheng, X., Wang, B., Zhao, Y., Hojaiji, H., Lin, S., Shih, R. M., Lin, H., Tamayosa, S., Ham, B., Stout, P., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201908507 · Cited by 66
Mugo, S. M., Robertson, S. V., & Lu, W. (2023) · Talanta · doi:10.1016/j.talanta.2023.124531 · Cited by 66
Minamiki, T., Tokito, S., & Menami, T. (2018) · Analytical Sciences · doi:10.2116/analsci.18sdn02 · Cited by 58
Khan, A., Haque, M. N., Kabiraz, D. C., Yeasin, A., Rashid, H. A., Sarker, A. C., & Hossain, G. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.114093 · Cited by 57
Wearable Carbon Nanotube-Based Biosensors on Gloves for Lactate
Luo, X., Shi, W., Yu, H., Xie, Z., Li, K., & Cui, Y. (2018) · Sensors · doi:10.3390/s18103398 · Cited by 56
Highly sensitive non-enzymatic lactate biosensor driven by porous nanostructured nickel oxide
Kim, S.-J., Yang, W. S., Kim, H.-J., Lee, H., Park, T. J., Seo, S., & Park, Y. M. (2019) · Ceramics International · doi:10.1016/j.ceramint.2019.08.037 · Cited by 54
Cunha‐Silva, H., & Arcos‐Martínez, M. J. (2018) · Talanta · doi:10.1016/j.talanta.2018.06.054 · Cited by 49
Golparvar, A. J., Kim, J., Boukhayma, A., Briand, D., & Carrara, S. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.133814 · Cited by 50
Yin, L., Sandhu, S. S., Liu, R., Khan, M. I., Wicker, C., García‐Gradilla, V., Zhou, J., Chang, A., Wu, S., Moon, J., et al. (2022) · Advanced Energy Materials · doi:10.1002/aenm.202203418 · Cited by 46
Effects of the cycling workload on core and local skin temperatures
Priego‐Quesada, J. I., Martínez, N., Palmer, R. S., Psikuta, A., Annaheim, S., Rossi, R. M., Corberán, J. M., de Anda, R. M. C. O., & Pérez‐Soriano, P. (2016) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2016.04.008 · Cited by 46
Yu, Y., Zhai, J., Xia, Y., & Dong, S. (2017) · Nanoscale · doi:10.1039/c7nr04335j · Cited by 43
Sweat rate and sweat composition during heat acclimation
Klous, L., de Ruiter, C. J., Alkemade, P., Daanen, H. A. M., & Gerrett, N. (2020) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2020.102697 · Cited by 45
Osmotically Enabled Wearable Patch for Sweat Harvesting and Lactate Quantification
Saha, T., Fang, J., Mukherjee, S., Knisely, C. T., Dickey, M. D., & Velev, O. D. (2021) · Micromachines · doi:10.3390/mi12121513 · Cited by 39
“On a contrary note, it is also proven that the sweat lactate concentration varies inversely with sweat rate [17].”
BackgroundResultInfluentialCinca-Morros, S., García-Rey, S., Álvarez‐Herms, J., Basabe‐Desmonts, L., & Benito‐Lopez, F. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.342988 · Cited by 39
Optical sensors for transdermal biomarker detection: A review
Amjad, A., & Xian, X. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116844 · Cited by 41
Choi, D.-H., Kitchen, G. B., Stewart, K. J., & Searson, P. C. (2020) · Scientific Reports · doi:10.1038/s41598-020-64406-5 · Cited by 35
Non-Invasive Multiparametric Approach To Determine Sweat–Blood Lactate Bioequivalence
Rabost-Garcia, G., Colmena-Rubil, V., Aguilar-Torán, J., Galí, J. V., Punter-Villagrasa, J., Casals‐Terré, J., Miribel‐Català, P. L., Muñoz, F. X., Cadefau, J. A., Padullés, J., et al. (2023) · ACS Sensors · doi:10.1021/acssensors.2c02614 · Cited by 41
A Wearable Amperometric Biosensor on a Cotton Fabric for Lactate
Luo, X., Yu, H., & Cui, Y. (2017) · IEEE Electron Device Letters · doi:10.1109/led.2017.2777474 · Cited by 39
“Sweat is secreted from skin, and lactate is a biomarker in sweat, which is closely related to the health condition [26], [27].”
BackgroundNoninvasive On-Skin Biosensors for Monitoring Diabetes Mellitus
Sedighi, A., Kou, T., Huang, H., & Li, Y. (2025) · Nano-Micro Letters · doi:10.1007/s40820-025-01843-9 · Cited by 52
Fujii, N., Halili, L., Singh, M. S., Meade, R. D., & Kenny, G. P. (2015) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00261.2015 · Cited by 33
Wu, Z., Cao, X., Yu, H., & Yu, C. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.3c05216 · Cited by 45
Wang, S., Zhang, G., Meng, H., & Li, L. (2012) · Skin Research and Technology · doi:10.1111/j.1600-0846.2012.00645.x · Cited by 37
Zhang, Y., Li, Z., Fan, X., Liu, Y., Li, Z., Zheng, Z., Lin, Z., Zhang, W., Mu, Q., Mo, G., et al. (2025) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.159209 · Cited by 50
Advanced Microfluidic‐Based Wearable Electrochemical Sensors for Continuous Biochemical Monitoring
Park, S., Kim, S., Lee, S.-J., Tsukruk, V. V., Park, S., & Lim, H. (2025) · Advanced Electronic Materials · doi:10.1002/aelm.202500010 · Cited by 31
Rao, L. T., Mandal, C. K., & Patolsky, F. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202503096 · Cited by 45
Rovira, M., Lafaye, C., Demuru, S., Kunnel, B. P., Aymerich, J., Cuenca, J., Serra-Graells, F., Margarit, J. M., Haque, R. I., Saubade, M., et al. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116560 · Cited by 28
Sweat rate and sweat composition following active or passive heat re-acclimation: A pilot study
Klous, L., de Ruiter, C. J., Alkemade, P., Daanen, H. A. M., & Gerrett, N. (2020) · Temperature · doi:10.1080/23328940.2020.1826287 · Cited by 26
Alginate Bead Biosystem for the Determination of Lactate in Sweat Using Image Analysis
García-Rey, S., Ojeda, E., Gunatilake, U. B., Basabe‐Desmonts, L., & Benito‐Lopez, F. (2021) · Biosensors · doi:10.3390/bios11100379 · Cited by 29
“Despite the different lactate levels previously reported, its concentration in sweat always shows higher levels during the first measurements and begins to decrease when the sweat rate increases, which dilutes the lactate, until a plateau is reached [18].”
BackgroundJia, Y., & Yan, B. (2023) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2023.122764 · Cited by 23
Recent Advances in Noninvasive Biosensors for Forensics, Biometrics, and Cybersecurity
McGoldrick, L. K., & Halámek, J. (2020) · Sensors · doi:10.3390/s20215974 · Cited by 33
Implications of the Onset of Sweating on the Sweat Lactate Threshold
Maeda, Y., Okawara, H., Sawada, T., Nakashima, D., Nagahara, J., Fujitsuka, H., Ikeda, K., Hoshino, S., Kobari, Y., Katsumata, Y., et al. (2023) · Sensors · doi:10.3390/s23073378 · Cited by 27
Effect of saddle height on skin temperature measured in different days of cycling
Priego‐Quesada, J. I., Carpes, F. P., Palmer, R. S., Pérez‐Soriano, P., & de Anda, R. M. C. O. (2016) · SpringerPlus · doi:10.1186/s40064-016-1843-z · Cited by 25
Amperometric Measurements by a Novel Aerosol Jet Printed Flexible Sensor for Wearable Applications
Tonello, S., Fapanni, T., Bonaldo, S., Giorgi, G., Narduzzi, C., Paccagnella, A., Serpelloni, M., Sardini, E., & Carrara, S. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3225014 · Cited by 21
“This large concentration of lactate in sweat and the large variation of this metabolite after physical exercises make its fluctuations optimal to be monitored quite easily [5] with respect to other electrolytes or metabolites that, on the contrary, present lower sensitivities [11].”
BackgroundSweat Analysis-Based Fatigue Monitoring during Construction Rebar Bending Tasks
Ma, J., Li, H., Yu, X., Fang, X., Fang, B., Zhao, Z., Huang, X., Anwer, S., & Xing, X. (2023) · Journal of Construction Engineering and Management · doi:10.1061/jcemd4.coeng-13233 · Cited by 21
Paper‐Based Wearable Patches for Real‐Time, Quantitative Lactate Monitoring
Ruggeri, E., Matzeu, G., Vergine, A., Nicolao, G. D., & Omenetto, F. G. (2023) · Advanced Sensor Research · doi:10.1002/adsr.202300141 · Cited by 19
Epidermal Biofuel Cells: Energy Harvesting from Human Perspiration
Jia, W., Valdés‐Ramírez, G., Bandodkar, A. J., Windmiller, J. R., & Wang, J. (2013) · Angewandte Chemie · doi:10.1002/ange.201302922 · Cited by 20
Anaerobic threshold using sweat lactate sensor under hypoxia
Okawara, H., Iwasawa, Y., Sawada, T., Sugai, K., Daigo, K., Seki, Y., Ichihara, G., Nakashima, D., Sano, M., Nakamura, M., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-49369-7 · Cited by 21
“In addition, in a respiratory infection epidemic such as COVID-19, using respiratory gas analyzers has become difficult due to the possibility of cross-infection.”
BackgroundOn-demand lactate monitoring towards assessing physiological responses in sedentary populations
Bhide, A., Lin, K., Muthukumar, S., & Prasad, S. (2021) · The Analyst · doi:10.1039/d1an00455g · Cited by 19
Simultaneous multi-location wireless monitoring of sweat lactate trends
Gillan, L., Teerinen, T., Suhonen, M., Kivimäki, L., & Alastalo, A. T. (2021) · Flexible and Printed Electronics · doi:10.1088/2058-8585/ac13c4 · Cited by 19
Metabolite Biometrics for the Differentiation of Individuals
Hair, M. E., Mathis, A. I., Brunelle, E., Halámková, L., & Halámek, J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00414 · Cited by 24
Rosati, G., Gherardi, G., Grigoletto, D., Marcolin, G., Cancellara, P., Mammucari, C., Scaramuzza, M., Toni, A. D., Reggiani, C., Rizzuto, R., et al. (2018) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2018.10.004 · Cited by 19
Dual-Valved Skin-Interfaced Microfluidic Device for Programmed Time-Control Sweat Collection
Yang, J. H., David, U., Noh, Y. S., & Koh, A. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.134441 · Cited by 22
Wearable Sweat Management Technologies
Wei, L., Li, Z., Dai, Z., Ding, L., Wei, H., Li, J., Zhu, H., & Zhu, Y. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202301812 · Cited by 21
Katsumata, Y., Muramoto, Y., Ishida, N., Takemura, R., Nagashima, K., Ikoma, T., Kawamatsu, N., Araki, M., Goda, A., Okawara, H., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-70001-9 · Cited by 16
“It is not surprising that the sensor using sweat cannot be utilized for all patients due to the diversity of sweat dynamics during exercise, including sweat volume [30].”
BackgroundThe effect of sweat sample storage condition on sweat content
Klous, L., Folkerts, M. A., Daanen, H. A. M., & Gerrett, N. (2021) · Temperature · doi:10.1080/23328940.2020.1867294 · Cited by 16
Elstub, L. J., Fine, S. J., & Zelik, K. E. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph182413115 · Cited by 13
“In addition, since thermal discomfort is related to skin sweating [35], it is possible that for some individuals a decrease in thermal comfort only occurs with tasks of longer duration, or when undertaking more demanding activities which cause increased sweat production [36].”
BackgroundMonitoring blood lactate dynamics through sweat and interstitial fluid biofluids
Boscarino, T., Djassemi, O., Khan, M. I., Chaiya, N., Moonla, C., Choi, B., Chang, A., Schena, E., Pecchia, L., Piemonte, V., et al. (2025) · Talanta · doi:10.1016/j.talanta.2025.128985 · Cited by 18
Cheng, C., Ganguly, S., Li, P., & Tang, X. S. (2024) · Biosensors · doi:10.3390/bios14120584 · Cited by 15
“The lactate concentration in eccrine sweat is influenced by various factors, including the kind of effort, duration, intensity, and sweat rate [25].”
Choi, D., Kitchen, G. B., Kim, J. S., Li, Y., Kim, K., Jeong, I. C., Nguyen, J., Stewart, K. J., Zeger, S. L., & Searson, P. C. (2019) · Scientific Reports · doi:10.1038/s41598-019-54202-1 · Cited by 12
Talukder, A., & Jo, J. (2025) · Wearable Technologies · doi:10.1017/wtc.2025.2 · Cited by 13
“The users of the passive exosuits may be able to perform longer, which will cause more sweat and skin heat production (Buono et al., 2010).”
Rodents and humans are able to detect the odour of L-Lactate
Mosienko, V., Chang, A. J., Alenina, N. V., Teschemacher, A. G., & Kasparov, S. (2017) · PLoS ONE · doi:10.1371/journal.pone.0178478 · Cited by 10
Sawada, T., Okawara, H., Nakashima, D., Ikeda, K., Nagahara, J., Fujitsuka, H., Hoshino, S., Maeda, Y., Katsumata, Y., Nakamura, M., et al. (2022) · Sensors · doi:10.3390/s22249585 · Cited by 11
Huynh, C., Brunelle, E., Agudelo, J., & Halámek, J. (2017) · Talanta · doi:10.1016/j.talanta.2017.04.016 · Cited by 11
Physical exercise and skin microcirculation
Lenasi, H. (2014) · Periodicum Biologorum · Cited by 14
The effect of heat acclimation on the sweat lactate concentration vs. sweat rate relationship
Weller, R. S., & Buono, M. J. (2022) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2022.103325 · Cited by 8
Self-citationSasaki, Y., & Minami, T. (2025) · Analytical Sciences · doi:10.1007/s44211-025-00750-8 · Cited by 8
The valley of death in translation: Challenges and pathways for wearable microfluidic sweat sensors
Yan, H., Fu, S., & Guo, Z. (2025) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.170306 · Cited by 6
Real-time on-body sweat sensing: Electrochemical insights, progress, and prospects
Saikrithika, S., Zahra, L., Theyagarajan, K., & Kim, Y.-J. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.118882 · Cited by 8
Merritt, J. R., Ozga, M., Chavez, P. J. D. D., Boolani, A., & Baker, L. B. (2024) · Scientific Reports · doi:10.1038/s41598-024-63057-0 · Cited by 3
“Additionally, previous studies have reported similar local sweat lactate concentrations 34,35 and local sweat cytokine concentrations and excretion rates for EGF and IL-8 36 as our study.”
Result
Metadata
- Authors
- Buono, M. J., Lee, N. V. L., & Miller, P. W.
- Affiliations
- San Diego State University (US)
- Corresponding author
- Buono, Michael J.
- ORCID
- Buono, Michael J.
- Venue
- The Journal of Physiological Sciences
- Publisher
- Elsevier BV
- Published
- 2010-03
- Volume
- 60
- Issue
- 2
- Pages
- 103-107
- ISSN
- 1880-6546 (ISSN-L)
- PMC
- PMC10717057
- OpenAlex
- W1994964334
- Cited by
- 128
- References
- 23
- Citations by year
- 2026: 12 · 2025: 11 · 2024: 13 · 2023: 13 · 2022: 10 · 2021: 14 · 2020: 12 · 2019: 7 · 2018: 7 · 2017: 9 · 2016: 6 · 2015: 4 · 2014: 1 · 2013: 4 · 2012: 4
- FWCI
- 0.88
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc-nd
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor, 5420 d)
- Locations
- The Journal of Physiological Sciences (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Keywords
- sweat lactate, exercise intensity, sweat rate, treadmill walking, heat stress, lactic acid production, age-predicted maximum heart rate
- MeSH terms
- Adult, Physical Exertion, Humans, Male, Models, Biological, Statistics as Topic, Sweat, Sweating, Exercise, Lactic Acid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.