Lactate in human sweat: a critical review of research to the present day
Open accessThe DOI matches its Crossref record; 66 of the 67 references it cites were found in a registry or an index.
Abstract
This review provides a critical overview of the literature published in the area of lactate in human sweat between 1934 and the present. The first section summarizes the relevant pieces of literature, the second evaluates the literature across a range of topics and the third presents potential applications for sweat lactate measurements. Key factors that may affect sweat lactate are discussed in detail in the second section of this review. Both acetylcholine and catecholamine hormonal signals can trigger sweating independently of one another; differences in sweat output and lactate concentrations are compared. The primary triggers for sweating, exercise and heat are also compared, with exercise-induced sweating being further examined with respect to the exercise intensity. This review examines the significant variations in sweat lactate between bodily sites as well the relationship to physiological parameters such as gender, age and physical fitness, along with the effect of climate adaptation on sweat lactate concentrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“However, lactate concentration becomes relatively stable after 1,100 s, indicating the stabilization of physiological responses to continuous, sub-maximal constant-exercise power output22.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [22]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Sweat is an attractive biofluid for point-of-care health monitoring because it can be locally and noninvasively induced and carries diverse biomolecules ranging from small electrolytes and metabolites to hormones and larger proteins that filter in from deeper in the body (1–5).”
From Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat (2019) · cites this paper as [5]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“sweat lactate can potentially serve as a sensitive marker of pressure ischaemia22;”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [22]
The cited source says what the claim attributes to it.
In the citing paper
“sweat lactate concentration typically exceeds that of blood lactate”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Derbyshire et al. 2012
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnostic and Statistical Manual of Mental Disorders
Williams, J. B. W., & First, M. (2013) · Encyclopedia of Social Work · doi:10.1093/acrefore/9780199975839.013.104 · Cited by 109,519
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90318-p · Cited by 5,737
Biochemistry of exercise-induced metabolic acidosis
Robergs, R. A., Ghiasvand, F., & Parker, D. (2004) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00114.2004 · Cited by 1,304 · cited 1×
“It is now known that blood lactate is not the cause of muscle fatigue per se, but remains an important indicator of oxygen-independent metabolism in muscles [38].”
BackgroundVariations in Regional Sweat Composition in Normal Human Males
Patterson, M. J., Galloway, S. D. R., & Nimmo, M. A. (2000) · Experimental Physiology · doi:10.1111/j.1469-445x.2000.02058.x · Cited by 438 · cited 1×
“A more detailed article on the topic of sweat composition variation was not published until 2000 [50].”
BackgroundThe physiology, pharmacology, and biochemistry of the eccrine sweat gland
Sato, K. (1977) · Reviews of Physiology, Biochemistry and Pharmacology · doi:10.1007/bfb0037089 · Cited by 384 · cited 3×
“In contrast to normal sympathetic postganglionic neurons which release norepinephrine, the neurons that terminate within sweat glands release acetylcholine, which then activates muscarinic receptors [12, 26].”
BackgroundPerspectives in Exercise Science and Sports Medicine
Lamb, D. R. (1988) · Cited by 263
The physiology of human perspiration
久野, 寧. (1934) · Churchill eBooks · Cited by 208
Analysis of metabolites in sweat as a measure of physical condition
Mitsubayashi, K., Suzuki, M., Tamiya, E., & Karube, I. (1994) · Analytica Chimica Acta · doi:10.1016/0003-2670(94)80004-9 · Cited by 153 · cited 1×
“Research by a group that had developed a novel lactate biosensor [44] involved an undisclosed number of untrained subjects performing a 3,000 m endurance run and an exhaustive stair sprint.”
BackgroundRegional and Individual Variations in the Function of the Human Eccrine Sweat Gland
Sato, K., & Dobson, R. L. (1970) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12259272 · Cited by 147 · cited 1×
“testing and discussing site variability of sweat lactate is very limited, although some literature compares sweat output without investigating lactate [48, 49].”
BackgroundHeat reactions of male and female Caucasians
Wyndham, C. H., Morrison, J. F., & Williams, C. G. (1965) · Journal of Applied Physiology · doi:10.1152/jappl.1965.20.3.357 · Cited by 135 · cited 1×
“, women require less sweat output to effectively regulate their core temperature [53, 54].”
Background
Research works printed but not linked: 3
- Javle, 1989, Lactate excretion in sweat produced with and without pharmacological stimulation before and during steady state exercise, Brit J Clin Pharmacol, 28, 746
- Javle H, Keaney NP, Smy JR, Lee M, Dillon S (1990) The effect of late restimulation with pilocarpine on the output of lactate in sweat in volunteers. Br J Clin Pharmacol 29:636-637
- Javle H, Keaney NP, Smy JR, Lee M, Dillon S (1990) The effect of restimulation with pilocarpine on the output of lactate in sweat. Br J Clin Pharmacol 29:150
Cited by
Items 101–200 of 316
Detection of lactate in human sweat via surface-modified, screen-printed carbon electrodes
Kumar, N., Lin, Y.-J., Huang, Y.-C., Liao, Y.-T., & Lin, S. (2023) · Talanta · doi:10.1016/j.talanta.2023.124888 · Cited by 45
Sweat rate and sweat composition during heat acclimation
Klous, L., de Ruiter, C. J., Alkemade, P., Daanen, H. A. M., & Gerrett, N. (2020) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2020.102697 · Cited by 45
Yu, Y., Zhai, J., Xia, Y., & Dong, S. (2017) · Nanoscale · doi:10.1039/c7nr04335j · Cited by 43
Rao, L. T., Mandal, C. K., & Patolsky, F. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202503096 · Cited by 45
Jia, S., Gao, H., Xue, Z., & Meng, X. (2022) · Biosensors · doi:10.3390/bios12111057 · Cited by 42
Non-Invasive Multiparametric Approach To Determine Sweat–Blood Lactate Bioequivalence
Rabost-Garcia, G., Colmena-Rubil, V., Aguilar-Torán, J., Galí, J. V., Punter-Villagrasa, J., Casals‐Terré, J., Miribel‐Català, P. L., Muñoz, F. X., Cadefau, J. A., Padullés, J., et al. (2023) · ACS Sensors · doi:10.1021/acssensors.2c02614 · Cited by 41
Recent advances in flexible sweat glucose biosensors
Zhou, W., He, Q., Ye, H., Ye, C., Wu, X., & Chu, J. (2021) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/ac14ef · Cited by 40
An Inkjet-Printed Flexible Non-Enzymatic Lactate Sensor for Clinical Blood Plasma Test
Huang, Y.-S., Chen, K., Cheng, Y., Lee, C., & Tsai, H. (2020) · IEEE Electron Device Letters · doi:10.1109/led.2020.2973343 · Cited by 40
“RECENT technology needs for real-time human health monitoring focus on the continuous detection of metabolites in human body for clinical diagnosis [1], [2].”
BackgroundOsmotically Enabled Wearable Patch for Sweat Harvesting and Lactate Quantification
Saha, T., Fang, J., Mukherjee, S., Knisely, C. T., Dickey, M. D., & Velev, O. D. (2021) · Micromachines · doi:10.3390/mi12121513 · Cited by 39
“Critical lactate levels in the body can abruptly alter the fluid pH and cause several detrimental effects on human health such as seizures, sepsis, renal failure, tumors [9], cerebral stroke [10], and panic disorders [11].”
BackgroundRecent Advances in Two-Dimensional MXene-Based Electrochemical Biosensors for Sweat Analysis
Ganesan, S., Ramajayam, K., Kokulnathan, T., & Palaniappan, A. (2023) · Molecules · doi:10.3390/molecules28124617 · Cited by 39
“Compared to other biofluids, sweat is high in several essential analytes such as glucose [17], lactate [18], cortisol [18], uric acid [19], interleukin [20], ammonium [21], sodium [22], potassium [23], calcium [24], iron [25], and zinc [26].”
BackgroundWearable Sensors for Physiological Condition and Activity Monitoring
Srikrishnarka, P., Haapasalo, J. A., Hinestroza, J. P., Sun, Z., & Nonappa, N. (2024) · Small Science · doi:10.1002/smsc.202300358 · Cited by 38
He, Q., Wang, C., Jain, R., Byrnes, J., Farquhar, E. R., Reed, E., Berezovsky, E., Chance, M. R., Lodowski, D. T., & An, R. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e34301 · Cited by 38
“Meanwhile, physiological lactate concentrations in sweat fall between 5 and 25 mM but can escalate to 43.7 mM during endurance exercise and peak at 115.8 mM in scenarios of exhaustive exercise [24,25].”
BackgroundInfluentialCinca-Morros, S., García-Rey, S., Álvarez‐Herms, J., Basabe‐Desmonts, L., & Benito‐Lopez, F. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.342988 · Cited by 39
Koushanpour, A., Gamella, M., & Katz, E. (2017) · Electroanalysis · doi:10.1002/elan.201700126 · Cited by 38
A Biomimetric Lactate Imprinted Smart Polymers as Capacitive Sweat Sensors
Mugo, S. M., Dhanjai, D., & Alberkant, J. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2974851 · Cited by 38
“Depending on the physical exertion state, the sweat lactate concentrations could increase to ∼50-80 mM [16]–[18].”
BackgroundXia, Q., Chen, J., & Dong, H. (2023) · Environmental Science & Technology · doi:10.1021/acs.est.3c00033 · Cited by 37
Iula, G., Miglione, A., Kalligosfyri, P. M., Spinelli, M., Amoresano, A., Natale, C. D., Darwısh, I. A., & Cinti, S. (2025) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-025-05905-0 · Cited by 37
Ma, C., Shang, X., Zhu, Z., Zheng, L., Sun, M., Cao, M., Bai, J., Du, Y., & Zhou, M. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117889 · Cited by 35
Next generation luminol derivative as powerful benchmark probe for chemiluminescence assays
Rink, S., Duerkop, A., von Wangelin, A. J., Seidel, M., & Baeumner, A. J. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.339161 · Cited by 35
Multifunctional Wearable System for Mapping Body Temperature and Analyzing Sweat
Alam, M. S., Kim, J. K., & Choi, J. (2023) · ACS Sensors · doi:10.1021/acssensors.3c00098 · Cited by 36
The Evolving Role of Proteins in Wearable Sweat Biosensors
Saldanha, D. J., Cai, A., & Courchesne, N. D. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.1c00699 · Cited by 34
Kim, H. J., Park, I., Pack, S. P., Lee, G., & Hong, Y. (2022) · Biosensors · doi:10.3390/bios12040248 · Cited by 34
“8 mM during endurance and intense exercise, respectively [27,28].”
BackgroundOsman, A. A. A., Geipel, G., Barkleit, A., & Bernhard, G. (2015) · Chemical Research in Toxicology · doi:10.1021/tx5004084 · Cited by 33
Noninvasive monitoring of diabetes and hypoxia by wearable flow-through biosensors
Karpova, E. V., & Karyakin, A. A. (2020) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2020.02.018 · Cited by 33
Recent Advances in Noninvasive Biosensors for Forensics, Biometrics, and Cybersecurity
McGoldrick, L. K., & Halámek, J. (2020) · Sensors · doi:10.3390/s20215974 · Cited by 33
Nelis, J. L. D., Bose, U., Broadbent, J. A., Hughes, J. M., Sikes, A. L., Anderson, A. R., Caron, K., Schmoelzl, S., & Colgrave, M. L. (2022) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.12935 · Cited by 32
Daboss, E. V., Tikhonov, D. V., Shcherbacheva, E. V., & Karyakin, A. A. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c02208 · Cited by 32
Mukundan, G., Ravipati, M., & Badhulika, S. (2024) · Microchimica Acta · doi:10.1007/s00604-024-06687-5 · Cited by 32
“The significance of analysing l -lactic acid ( l -LA) as a potential biomarker has always gained prominence, primarily due to its association with various conditions like restricted oxygen levels, pressure ischaemia, cystic fibrosis, Frey’s syndrome, etc. [1].”
Advanced Microfluidic‐Based Wearable Electrochemical Sensors for Continuous Biochemical Monitoring
Park, S., Kim, S., Lee, S.-J., Tsukruk, V. V., Park, S., & Lim, H. (2025) · Advanced Electronic Materials · doi:10.1002/aelm.202500010 · Cited by 31
The positioning of biofuel cells-based biobatteries for net-zero energy future
Patra, S., Verma, J., Mishra, Y. K., Kurinec, S. K., Wang, Q., Syväjärvi, M., & Tiwari, A. (2023) · Journal of Energy Storage · doi:10.1016/j.est.2023.107919 · Cited by 32
Development of Flexible Electronic Biosensors for Healthcare Engineering
Zhao, Y. G., Yan, J., Cheng, J., Fu, Y., Zhou, J., Yan, J., & Guo, J. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3287291 · Cited by 30
“Lactate concentration reveals the body’s metabolism and movement level [202], and temperature can indicate body inflammation occurrences [203].”
BackgroundNanoarchitectonics of point-of-care diagnostics for sweat biomarkers analysis
Lin, X., Vasanth, A., Ashok, A., Phan, H., Koo, K. M., Amin, M. A., Kaneti, Y. V., Salomón, C., Hossain, M. S. A., Yamauchi, Y., et al. (2024) · Nano Materials Science · doi:10.1016/j.nanoms.2024.01.010 · Cited by 30
Alginate Bead Biosystem for the Determination of Lactate in Sweat Using Image Analysis
García-Rey, S., Ojeda, E., Gunatilake, U. B., Basabe‐Desmonts, L., & Benito‐Lopez, F. (2021) · Biosensors · doi:10.3390/bios11100379 · Cited by 29
“The main function of sweat is thermoregulation, leading to heat dissipation by water evaporation [1] in response to an increase in body core temperature.”
BackgroundMethodInfluentialA Simple and Sensitive Wearable SERS Sensor Utilizing Plasmonic-Active Gold Nanostars
Atta, S., Zhao, Y., Sanchez, S., & Vo‐Dinh, T. (2024) · ACS Omega · doi:10.1021/acsomega.4c05140 · Cited by 29
“54 We postulate that the low concentrations observed in our study were influenced by these factors.”
Towards a transdermal membrane biosensor for the detection of lactate in body fluids
Wang, Y., Ausri, I. R., Wang, Z., Derry, C., & Tang, X. S. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.127645 · Cited by 28
Sweat analysis for urea sensing: trends and challenges
Futane, A., Senthil, M., Jayashree, S., Srinivasan, A., Kalpana, R., & Narayanamurthy, V. (2023) · Analytical Methods · doi:10.1039/d3ay01089a · Cited by 28
Recent Advances in Self‐Powered Electrochemical Biosensors for Early Diagnosis of Diseases
Galstyan, V., D’Onofrio, I., Liboà, A., Giorgio, G. D., Vurro, D., Rovati, L. L., Tarabella, G., & D’Angelo, P. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202400395 · Cited by 27
Supercapacitor-powered wearable biosensor for continuous lactate monitoring from sweat
Asadian, E., Hekmat, F., Kahnamouei, M. H., Mohammadpour, R., Shahrokhian, S., & Sasanpour, P. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117226 · Cited by 27
Dual-gate thin film transistor lactate sensors operating in the subthreshold regime
Baek, S., Matsui, H., Mano, T., Park, J. A., Jo, Y., Lee, Y., Tokito, S., Kwon, J., & Jung, S. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114958 · Cited by 27
Emerging trends in wearable glove-based sensors: A review
Tsong, J. L., Robert, R., & Khor, S. M. (2023) · Analytica Chimica Acta · doi:10.1016/j.aca.2023.341277 · Cited by 27
Simultaneous detection of urea and lactate in sweat based on a wearable sweat biosensor
Yang, H., Ji, Y., Shen, K., Qian, Y., & Ye, C. (2023) · Biomedical Optics Express · doi:10.1364/boe.505004 · Cited by 26
A Flexible 3D Organic Preamplifier for a Lactate Sensor
Baek, S., Kwon, J., Mano, T., Tokito, S., & Jung, S. (2020) · Macromolecular Bioscience · doi:10.1002/mabi.202000144 · Cited by 26
Sweat rate and sweat composition following active or passive heat re-acclimation: A pilot study
Klous, L., de Ruiter, C. J., Alkemade, P., Daanen, H. A. M., & Gerrett, N. (2020) · Temperature · doi:10.1080/23328940.2020.1826287 · Cited by 26
Li, P., Kalambate, P. K., Harris, K. D., Jemere, A. B., & Tang, X. S. (2024) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2024.100455 · Cited by 25
Cai, J., Deng, W., Zhu, Z., Zheng, L., Sun, M., Ma, C., Bai, J., Bo, X., & Zhou, M. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c01624 · Cited by 24
The Potential of Biomarkers in the Early Detection of Pressure Ulcers
Bader, D. L., & Oomens, C. W. J. (2018) · Springer eBooks · doi:10.1007/978-1-4471-7413-4_1 · Cited by 24
Rajendran, J., Pei, X. M., Chakoma, S. M., Ghandehari, A., Negrete, J. A. T., Najafikhoshnoo, S., & Esfandyarpour, R. (2026) · Nature Biomedical Engineering · doi:10.1038/s41551-026-01670-2 · Cited by 25
Jia, Y., & Yan, B. (2023) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2023.122764 · Cited by 23
Interaction study of amino acid on novel Kagome phosphorene nanotube – A DFT outlook
Bhuvaneswari, R., Nagarajan, V., & Chandiramouli, R. (2020) · Computational and Theoretical Chemistry · doi:10.1016/j.comptc.2020.112903 · Cited by 22
Dual-Valved Skin-Interfaced Microfluidic Device for Programmed Time-Control Sweat Collection
Yang, J. H., David, U., Noh, Y. S., & Koh, A. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.134441 · Cited by 22
Novel Sweat-Based Wearable Device for Advanced Monitoring of Athletic Physiological Biometrics
Aguilar-Torán, J., Rabost-Garcia, G., Toinga-Villafuerte, S., Álvarez-Carulla, A., Colmena-Rubil, V., Fajardo-Garcia, A., Cardona-Bonet, A., Casals‐Terré, J., Muñoz-Pascual, X., Miribel‐Català, P. L., et al. (2023) · Sensors · doi:10.3390/s23239473 · Cited by 23
“The electronics capture the response of every sensor using custom analog instrumentations and the ADCs of the microcontroller.”
MethodAmperometric Measurements by a Novel Aerosol Jet Printed Flexible Sensor for Wearable Applications
Tonello, S., Fapanni, T., Bonaldo, S., Giorgi, G., Narduzzi, C., Paccagnella, A., Serpelloni, M., Sardini, E., & Carrara, S. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3225014 · Cited by 21
Dutkiewicz, E. P., Hsieh, K.-T., Urban, P. L., & Chiu, H. (2020) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfaa009 · Cited by 21
Multimodal Wearable Platform with Simultaneous Electrochemical and Biophotonic Sensing
Evert, B., Peterson, K., Songkakul, T., Bozkurt, A. Y., & Daniele, M. A.-A. (2025) · ACS Sensors · doi:10.1021/acssensors.4c03492 · Cited by 20
Debnath, S., Debnath, T., & Paul, M. (2025) · Sensors · doi:10.3390/s25216553 · Cited by 21
Wearable Sweat Management Technologies
Wei, L., Li, Z., Dai, Z., Ding, L., Wei, H., Li, J., Zhu, H., & Zhu, Y. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202301812 · Cited by 21
Ma, J., Li, H., Anwer, S., Umer, W., Antwi‐Afari, M. F., & Xiao, E. B. (2024) · International Journal of Occupational Safety and Ergonomics · doi:10.1080/10803548.2024.2330242 · Cited by 21
“Several studies have explored the elements of sweat to determine whether they can reflect the physiological state of individuals [74,75].”
Rink, S., Duerkop, A., & Baeumner, A. J. (2023) · Analysis & Sensing · doi:10.1002/anse.202200111 · Cited by 19
On-demand lactate monitoring towards assessing physiological responses in sedentary populations
Bhide, A., Lin, K., Muthukumar, S., & Prasad, S. (2021) · The Analyst · doi:10.1039/d1an00455g · Cited by 19
Simultaneous multi-location wireless monitoring of sweat lactate trends
Gillan, L., Teerinen, T., Suhonen, M., Kivimäki, L., & Alastalo, A. T. (2021) · Flexible and Printed Electronics · doi:10.1088/2058-8585/ac13c4 · Cited by 19
Paper‐Based Wearable Patches for Real‐Time, Quantitative Lactate Monitoring
Ruggeri, E., Matzeu, G., Vergine, A., Nicolao, G. D., & Omenetto, F. G. (2023) · Advanced Sensor Research · doi:10.1002/adsr.202300141 · Cited by 19
Monitoring blood lactate dynamics through sweat and interstitial fluid biofluids
Boscarino, T., Djassemi, O., Khan, M. I., Chaiya, N., Moonla, C., Choi, B., Chang, A., Schena, E., Pecchia, L., Piemonte, V., et al. (2025) · Talanta · doi:10.1016/j.talanta.2025.128985 · Cited by 18
Wu, X., Jin, D., Li, M., Luo, X., & Wang, L. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.110327 · Cited by 18
Primary pulmonary lymphoepithelioma-like carcinoma
Fan, Y., Li, C., Qin, J., & Lu, H. (2020) · Medical Oncology · doi:10.1007/s12032-020-1344-3 · Cited by 18
“This disease has little associations with smoking and gender, and the average patient age is reduced compared with those of other lung tumors [2].”
BackgroundZhou, L. (2021) · International Journal of Electrochemical Science · doi:10.20964/2021.10.54 · Cited by 18
An overview of healthcare monitoring by flexible electronics
Hu, J., Li, R., Liu, Y., & Su, Y. (2018) · Science China Physics Mechanics and Astronomy · doi:10.1007/s11433-018-9239-9 · Cited by 18
Yang, Q., Liao, J., Feng, L., Wang, S., Zhao, Z., Wang, J., Bu, Y., Zhang, D., & Zhang, D. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116194 · Cited by 17
HoloChemie - Sustainable Fabrication of Soft Biochemical Holographic Devices for Ubiquitous Sensing
Roy, S., Chowdhury, M.-U.-S., Noim, J. O., Pandey, R., & Nittala, A. S. (2024) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/3654777.3676448 · Cited by 17
“Lactate in sweat provides unique information about the general health status of the individual, including pressure ischemia and insufcient oxidative metabolism [13].”
Fatani, F., Rauf, S., Banerjee, A., & Shamim, A. (2025) · ACS Sensors · doi:10.1021/acssensors.5c00470 · Cited by 16
A Tube-Integrated Painted Biosensor for Glucose and Lactate
Shi, W., Luo, X., & Cui, Y. (2018) · Sensors · doi:10.3390/s18051620 · Cited by 16
“Lactate is another important biomedical indicator and can be detected in oral fluids or sweat [23,24], thus making it extremely suitable for building non-invasive biosensors.”
BackgroundKinetic changes in sweat lactate following fatigue during constant workload exercise
Okawara, H., Sawada, T., Nakashima, D., Maeda, Y., Minoji, S., Morisue, T., Katsumata, Y., Matsumoto, M., Nakamura, M., & Nagura, T. (2022) · Physiological Reports · doi:10.14814/phy2.15169 · Cited by 16
Axillary Microbiota Is Associated with Cognitive Impairment in Parkinson’s Disease Patients
Arıkan, M., Yıldız, Z., Demir, T. K., Yılmaz, N. H., Şen, A., Hanoğlu, L., & Yıldırım, S. (2022) · Microbiology Spectrum · doi:10.1128/spectrum.02358-21 · Cited by 17
“Propionate is a short-chain fatty acid in humans produced by microbial fermentation from lactate and is one of the main components of human sweat (22).”
BackgroundCollection of the Abstracts of the 2019Sp PMD: Translational Myology and Mobility Medicine
Carraro, U. (2019) · European Journal of Translational Myology · doi:10.4081/ejtm.2019.8155 · Cited by 17
Unsubstituted phenothiazine as a superior water-insoluble mediator for oxidases
Sekretareva, A., Vagin, M. Y., Beni, V., Turner, A. P. F., & Karyakin, A. A. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.09.071 · Cited by 16
“The dynamic range of the biosensor covers the physiological level of lactate in an exercise induced sweat (Derbyshire et al. 2012), which is attractive for sport medicine applications.”
BackgroundCheng, C., Ganguly, S., Li, P., & Tang, X. S. (2024) · Biosensors · doi:10.3390/bios14120584 · Cited by 15
“Elevated lactate levels in the body can rapidly disrupt fluid pH and lead to several adverse health consequences, including seizures, sepsis, renal failure, malignancies, cerebral stroke, and panic disorders [24].”
Single-Use Printed Biosensor for L-Lactate and Its Application in Bioprocess Monitoring
Theuer, L., Randek, J., Junne, S. G., Neubauer, P. B., Mandenius, C., & Beni, V. (2020) · Processes · doi:10.3390/pr8030321 · Cited by 15
“The majority of these rely on the use of enzymes such as lactate oxidase or lactate dehydrogenase incorporated in a supporting membrane [21].”
BackgroundNoninvasive Epidermal Metabolite Profiling
Stoffers, K. M., Cronkright, A. A., Huggins, G. S., & Baleja, J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c02274 · Cited by 14
Fluid-based wearable sensors: a turning point in personalized healthcare
VURAL, B., Uludağ, İ., İNCE, B., Özyurt, C., ÖZTÜRK, F., & Sezgintürk, M. K. (2023) · TURKISH JOURNAL OF CHEMISTRY · doi:10.55730/1300-0527.3588 · Cited by 14
“It has been reported that sweat glucose is related to blood glucose [50], and sweat lactate is potentially a sensitive marker of pressure ischemia [51].”
BackgroundPhysical exercise and skin microcirculation
Lenasi, H. (2014) · Periodicum Biologorum · Cited by 14
The Physiology of Thermoregulation in Exercise: A Brief Review
Lenasi, H., & Šijanec, J. (2023) · Southeastern European medical journal · doi:10.26332/seemedj.v7i1.275 · Cited by 14
Tasangtong, B., Sirichan, K., Hasoon, C., Nongkhai, P. ์., Rodthongkum, N., & Sameenoi, Y. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.135513 · Cited by 13
Supported NiO x Nanocatalysts on Graphene for Nonenzymatic Lactate Sensing
Gao, W., Guan, X., Wang, J., Heinig, N. F., Thomas, J. P., Zhang, L., Ding, K., & Leung, K. T. (2024) · ACS Applied Nano Materials · doi:10.1021/acsanm.3c06246 · Cited by 13
Lin, F., Anaya, D. V., Gong, S. P., Yap, L. W., Yan, L., Yong, Z., & Cheng, W. (2024) · ACS Sensors · doi:10.1021/acssensors.4c01635 · Cited by 14
Fundamental Study of a Wristwatch Sweat Lactic Acid Monitor
Konno, S., & Kudo, H. (2024) · Biosensors · doi:10.3390/bios14040187 · Cited by 12
“However, it cannot be measured based on the sweat rate, and its kinetics remain unclear [12,13].”
BackgroundEscalona-Villalpando, R. A., Viveros-Palma, K., Espinosa‐Lagunes, F. I., Morales, J. A. R., Arriaga, L. G., Macazo, F. C., Minteer, S. D., & García, J. L. (2022) · Biosensors · doi:10.3390/bios12111025 · Cited by 12
Nguenouho, O. S. B., Chevalier, A., Potelon, B., Quendo, C., Bénédicto, J., & Simon, B. M. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3312490 · Cited by 12
“Blood lactate is also a useful indicator for medical emergency teams: its level and clearance ratio are also well-known as useful parameters in the diagnosis and prognosis of septic patients [13], [14].”
BackgroundHighly sensitive on-skin flexible Sb2O3/Sb thin film pH sensor for real-time sweat sensing
Jaiswal, J., Mizushima, S., Kanno, S., Sasaki, K., Kabayama, K., Kaneda‐Nakashima, K., Tsuyuki, Y., & Tsuchiya, K. (2024) · Materials Research Bulletin · doi:10.1016/j.materresbull.2024.112795 · Cited by 13
Fluid-permeable enzymatic lactate sensors for micro-volume specimen
Kai, H., Kato, Y., Toyosato, R., & Nishizawa, M. (2018) · The Analyst · doi:10.1039/c8an00979a · Cited by 12
García-Rey, S., Gil-Hernández, E., Gunatilake, U. B., Basabe‐Desmonts, L., & Benito‐Lopez, F. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.133514 · Cited by 12
Okano, S., Nishizawa, H., Yui, J., & Nakamura, A. (2022) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-022-00482-6 · Cited by 11
“In addition to saliva, urine [17, 18] and sweat [19, 20] are also useful as specimens that can be collected noninvasively to determine lactate.”
BackgroundBioengineered Lactate Oxidase Mutants for Enhanced Electrochemical Performance at Acidic pH
García-Morales, R., Zárate‐Romero, A., Wang, J., & Vázquez-Duhalt, R. (2023) · ChemElectroChem · doi:10.1002/celc.202300296 · Cited by 11
Rocha, K. N., da Silva, J. A. F., & de Jesus, D. P. (2023) · Electrophoresis · doi:10.1002/elps.202300179 · Cited by 11
“These concentrations are similar to those found in the blood, making sweat suitable for clinical analysis because of the advantages mentioned earlier [4, 13].”
BackgroundHuynh, C., Brunelle, E., Agudelo, J., & Halámek, J. (2017) · Talanta · doi:10.1016/j.talanta.2017.04.016 · Cited by 11
Plasmonic wearable adhesive patch for a SERS-based sweat sensor
Puravankara, V., Morayi, A., Hanosh, S., & George, S. D. (2025) · RSC Advances · doi:10.1039/d5ra00529a · Cited by 10
Zhou, Q., Wang, D., Yang, Z., & Chen, X. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.114760 · Cited by 10
Methods of energy generation from the human body: a literature review
Al-Nabulsi, J., El-Sharo, S., Salawy, N., & Al-Doori, H. (2019) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2019.1658818 · Cited by 10
“The monitoring of sweat lactate can aid in the detection of pressure ischaemia, tissue perfusion, diagnosis of cystic fibrosis, diagnosis of Frey’s Syndrome and for diagnostic markers of panic disorder [89].”
MethodWearable Electronic Tongue for Non-Invasive Assessment of Human Sweat
Falk, M., Nilsson, E. J., Cirovic, S., Tudosoiu, B., & Shleev, S. (2021) · Sensors · doi:10.3390/s21217311 · Cited by 10
A Wearable Patch for Prolonged Sweat Lactate Harvesting and Sensing
Saha, T., Fang, J., Yokus, M. A., Mukherjee, S., Bozkurt, A. Y., Daniele, M. A.-A., Dickey, M. D., & Velev, O. D. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630881 · Cited by 10
“The earlier work in the literature has quantified sweat and blood lactate levels using various (and mostly colorimetric and electrochemical) sensing mechanisms [4,6,10,11].”
BackgroundMethodWang, R., Yang, X., Tian, F., Zhu, Z., Teng, P., Zhang, Y., Wen, X., Li, X., Guan, A., Wang, Y., et al. (2025) · Optics & Laser Technology · doi:10.1016/j.optlastec.2025.112975 · Cited by 9
Cai, J., Ma, C.-B., Bai, J., Bo, X., & Zhou, M. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.118474 · Cited by 9
Metadata
- Authors
- Derbyshire, P. J., Barr, H., Davis, F., & Higson, S. P. J.
- Affiliations
- Cranfield University (GB)
- Gloucestershire Royal Hospital (GB)
- Corresponding author
- Davis, Frank
- Venue
- The Journal of Physiological Sciences
- Publisher
- Elsevier BV
- Published
- 2012-11
- Volume
- 62
- Issue
- 6
- Pages
- 429-440
- ISSN
- 1880-6546 (ISSN-L)
- PMC
- PMC10717375
- OpenAlex
- W1963528082
- Cited by
- 280
- References
- 67
- Citations by year
- 2026: 23 · 2025: 31 · 2024: 38 · 2023: 40 · 2022: 27 · 2021: 29 · 2020: 34 · 2019: 17 · 2018: 16 · 2017: 8 · 2016: 9 · 2015: 2 · 2014: 3 · 2013: 2
- FWCI
- 0.24
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc-nd
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor, 4444 d)
- Locations
- The Journal of Physiological Sciences (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute for Health and Care Research (NF-SI-0611-10065)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
- Keywords
- sweat lactate, human sweat, sweating, acetylcholine, catecholamines, exercise-induced sweating, exercise intensity, inter-site variability, sex differences, age differences, physical fitness, climate change adaptation
- MeSH terms
- Adaptation, Physiological, Climate, Humans, Sweat, Sweating, Lactic Acid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.