Cited by 40Electrochemical sensors and biosensorsAdvanced Sensor and Energy Harvesting MaterialsAdvanced biosensing and bioanalysis techniques

Recent advances in flexible sweat glucose biosensors

Zhou, Wenbin, He, Qian, Ye, Haifeng, Ye, Changqing, Wu, Xing, Chu, Junhao·2021·Journal of Physics D: Applied Physics

Abstract

Continuous monitoring of the blood glucose levels is necessary for its diagnosis and treatment. In recent years, researchers have discovered a correlation between sweat glucose and blood glucose. The methodology of obtaining the value of blood glucose by detecting glucose in sweat is expected to replace conventional diabetes detection. Flexible sweat glucose biosensor owns the characteristics of stretchability, comfortability, and the capability of non-invasive and is a promising candidate for non-invasive diabetes monitoring. In this review, we summarize the latest developments in research and applications of the flexible sweat glucose biosensors based on enzyme and non-enzymatic detection methodologies. The correction methodologies, challenges and outlooks of the wearable sweat glucose biosensor technology are also be discussed.

Integrity signals

Registry

Crossref · 10.1088/1361-6463/ac14ef

Cites

186 of 186 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A correlation between sweat glucose and blood glucose exists, and obtaining blood glucose values by detecting glucose in sweat is expected to replace conventional diabetes blood glucose monitoring practices.

    “A correlation between sweat glucose and blood glucose exists and obtaining blood glucose values by detecting glucose in sweat is thus expected to replace conventional diabetes blood glucose monitoring practices 83,84”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Zhou, W., He, Q., Ye, H., Ye, C., Wu, X., & Chu, J.
Affiliations
  • East China Normal University (CN)
  • Fudan University (CN)
Corresponding author
  • Ye, Haifeng
  • Ye, Changqing
  • Wu, Xing
Venue
Journal of Physics D: Applied Physics
Published
2021-08-02
Volume
54
Issue
42
Pages
423001
ISSN
  • 0022-3727 (ISSN-L)
  • 1361-6463
OpenAlex
W3186285150
Cited by
40
References
186
Citations by year
2026: 4 · 2025: 10 · 2024: 9 · 2023: 10 · 2022: 7
FWCI
1.91
Type
journal article
Language
en
Open access
closed
Locations
Journal of Physics D Applied Physics (publishedVersion)
Funders
  • Open Research Projects of Zhejiang Lab (2021MC0AB06)
  • Projects of Science and Technology Commission of Shanghai Municipality (19ZR1473800)
  • Fundamental Research Funds for the Central Universities
  • “Shuguang Program” supported by Shanghai Education Development Foundation
  • National Natural Science Foundation of China (62074057)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
Keywords
flexible biosensors, non-invasive glucose monitoring, diabetes monitoring, blood glucose, non-enzymatic glucose sensing, wearable sensors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review