Purpose Advanced morphology analysis and image-based hemodynamic simulations are increasingly used to assess the rupture risk of intracranial aneurysms (IAs). However, the accuracy of those results strongly depends on the quality of the vessel wall segmentation.Methods To evaluate state-of-the-art segmentation approaches, the Multiple Aneurysms AnaTomy CHallenge (MATCH) was announced. Participants carried out segmentation in three anonymized 3D DSA datasets (left and right anterior, posterior circulation) of a patient harboring five IAs. Qualitative and quantitative inter-group comparisons were carried out with respect to aneurysm volumes and ostia. Further, over- and undersegmentation were evaluated based on highly resolved 2D images. Finally, clinically relevant morphological parameters were calculated.Results Based on the contributions of 26 participating groups, the findings reveal that no consensus regarding segmentation software or underlying algorithms exists. Qualitative similarity of the aneurysm representations was obtained. However, inter-group differences occurred regarding the luminal surface quality, number of vessel branches considered, aneurysm volumes (up to 20%) and ostium surface areas (up to 30%). Further, a systematic oversegmentation of the 3D surfaces was observed with a difference of approximately 10% to the highly resolved 2D reference image. Particularly, the neck of the ruptured aneurysm was overrepresented by all groups except for one. Finally, morphology parameters (e.g., undulation and non-sphericity) varied up to 25%.Conclusions MATCH provides an overview of segmentation methodologies for IAs and highlights the variability of surface reconstruction. Further, the study emphasizes the need for careful processing of initial segmentation results for a realistic assessment of clinically relevant morphological parameters.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
A method for registration of 3-D shapes
Besl, P. J., & McKay, N. D. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121791 · Cited by 18,103
Object modelling by registration of multiple range images
Chen, Y., & Medioni, G. (1992) · Image and Vision Computing · doi:10.1016/0262-8856(92)90066-c · Cited by 3,154
The Physiological Principle of Minimum Work: I. The Vascular System and the Cost of Blood Volume
Murray, C. D. (1926) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.12.3.207 · Cited by 2,087
Meng, H., Tutino, V. M., Xiang, J., & Siddiqui, A. (2014) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3558 · Cited by 955
An image-based modeling framework for patient-specific computational hemodynamics
Antiga, L., Piccinelli, M., Botti, L., Ene-Iordache, B., Remuzzi, A., & Steinman, D. A. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0420-1 · Cited by 850
Hemodynamic–Morphologic Discriminants for Intracranial Aneurysm Rupture
Xiang, J., Natarajan, S. K., Tremmel, M., Ma, D., Mocco, J., Hopkins, L. N., Siddiqui, A. H., Levy, E. I., & Meng, H. (2011) · Stroke · doi:10.1161/strokeaha.110.592923 · Cited by 782
MORPHOLOGY PARAMETERS FOR INTRACRANIAL ANEURYSM RUPTURE RISK ASSESSMENT
Dhar, S., Tremmel, M., Mocco, J., Kim, M., Yamamoto, J., Siddiqui, A. H., Hopkins, L. N., & Meng, H. (2008) · Neurosurgery · doi:10.1227/01.neu.0000316847.64140.81 · Cited by 589
Cebral, J. R., Mut, F., Weir, J., & Putman, C. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2419 · Cited by 470
Quantified aneurysm shape and rupture risk
Raghavan, M. L., Ma, B., & Harbaugh, R. E. (2005) · Journal of Neurosurgery · doi:10.3171/jns.2005.102.2.0355 · Cited by 413
Cebral, J. R., Mut, F., Raschi, M., Scrivano, E., Ceratto, R., Lylyk, P., & Putman, C. M. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2398 · Cited by 390
Cited by
Li, G., Wang, H., Zhang, M., Tupin, S., Qiao, A., Liu, Y., Ohta, M., & Anzai, H. (2021) · Communications Biology · doi:10.1038/s42003-020-01638-1 · Cited by 165
Computational fluid dynamics as a risk assessment tool for aneurysm rupture
Murayama, Y., Fujimura, S., Suzuki, T., & Takao, H. (2019) · Neurosurgical FOCUS · doi:10.3171/2019.4.focus19189 · Cited by 113
Berg, P., Saalfeld, S., Voß, S., Beuing, O., & Janiga, G. (2019) · Neurosurgical FOCUS · doi:10.3171/2019.4.focus19181 · Cited by 103
Self-citationSteinman, D. A., & Pereira, V. M. (2019) · Neurosurgical FOCUS · doi:10.3171/2019.4.focus19123 · Cited by 73
Steinman, D. A., & Migliavacca, F. (2018) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-018-00393-z · Cited by 71
Metadata
- Authors
- Berg, P., Voß, S., Saalfeld, S., Janiga, G., Bergersen, A. W., Valen-Sendstad, K., Bruening, J., Goubergrits, L., Spuler, A., Cancelliere, N. M., Steinman, D. A., Pereira, V. M., Chiu, T. L., Tsang, A. C. O., Chung, B. J., Cebral, J. R., Cito, S., Pallarès, J., Copelli, G., Csippa, B., Paál, G., Fujimura, S., Takao, H., Hodis, S., Hille, G., Karmonik, C., Elias, S., Kellermann, K., Khan, M. O., Marsden, A. L., Morales, H. G., Piskin, S., Finol, E. A., Pravdivtseva, M., Rajabzadeh-Oghaz, H., Paliwal, N., Meng, H., Seshadhri, S., Howard, M., Shojima, M., Sugiyama, S.-I., Niizuma, K., Sindeev, S., Frolov, S., Wagner, T., Brawanski, A., Qian, Y., Wu, Y.-A., Carlson, K. D., Dragomir-Daescu, D., & Beuing, O.
- Affiliations
- Otto-von-Guericke-Universität Magdeburg (DE)
- Simula Research Laboratory (NO)
- Charité – Universitätsmedizin Berlin (DE)
- Helios Hospital Berlin-Buch (DE)
- University Health Network (CA)
- University of Toronto (CA)
- University of Hong Kong (HK)
- George Mason University (US)
- Universitat Rovira i Virgili (ES)
- University of Parma (IT)
- Budapest University of Technology and Economics (HU)
- Jikei University School of Medicine (JP)
- Texas A&M University – Kingsville (US)
- Houston Methodist (US)
- Stanford University (US)
- Universidad Mayor (CL)
- The University of Texas at San Antonio (US)
- University Hospital Schleswig-Holstein (DE)
- University at Buffalo, State University of New York (US)
- Medtronic (India) (IN)
- Synopsys (United States) (US)
- Saitama Medical University (JP)
- Tohoku University (JP)
- OTH Regensburg (DE)
- University Hospital Regensburg (DE)
- Macquarie University (AU)
- Mayo Clinic (US)
- University Hospital Magdeburg (DE)
- Corresponding author
- Berg, Philipp
- ORCID
- Berg, Philipp
- Voß, Samuel
- Saalfeld, Sylvia
- Janiga, Gábor
- Bergersen, Aslak W.
- Goubergrits, Leonid
- Spuler, Andreas
- Cancelliere, Nicole M.
- Steinman, David A.
- Chiu, Tin Lok
- Tsang, Anderson Chun On
- Chung, Bong Jae
- Cebral, Juan R.
- Cito, Salvatore
- Pallarès, Jordi
- Paál, György
- Fujimura, Soichiro
- Takao, Hiroyuki
- Hodis, Simona
- Karmonik, Christof
- Elias, Saba
- Khan, Muhammad Owais
- Marsden, Alison L.
- Morales, Hernán G.
- Finol, Ender A.
- Pravdivtseva, Mariya
- Rajabzadeh-Oghaz, Hamidreza
- Paliwal, Nikhil
- Meng, Hui
- Shojima, Masaaki
- Sugiyama, Shin-ichiro
- Niizuma, Kuniyasu
- Brawanski, Alexander
- Qian, Yi
- Beuing, Oliver
- Venue
- Cardiovascular Engineering and Technology
- Published
- 2018-09-06
- Volume
- 9
- Issue
- 4
- Pages
- 565-581
- ISSN
- 1869-408X (ISSN-L)
- 1869-4098
- OpenAlex
- W2891940995
- Cited by
- 79
- References
- 49
- Citations by year
- 2026: 1 · 2025: 8 · 2024: 16 · 2023: 8 · 2022: 11 · 2021: 11 · 2020: 9 · 2019: 13 · 2018: 1
- FWCI
- 5.77
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.springer.com/tdm (tdm)
- Locations
- Cardiovascular Engineering and Technology (publishedVersion)
- PubMed (publishedVersion)
- Rovira & Virgili repository (submittedVersion, cc-by)
- University of Regensburg Publication Server (University of Regensburg) (submittedVersion)
- Institutional Repositories DataBase (IRDB) (submittedVersion, cc-by-nc-nd)
- Funders
- Bundesministerium für Bildung und Forschung (13GW0095A)
- Deutsche Forschungsgemeinschaft (399581926)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Intracranial Aneurysms: Treatment and Complications
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cerebrovascular and Carotid Artery Diseases
- Keywords
- intracranial aneurysm, vessel wall segmentation, segmentation benchmark, aneurysm morphology, aneurysm volume, surface reconstruction, aneurysm rupture risk, 3D digital subtraction angiography, aneurysm neck
- MeSH terms
- Blood Flow Velocity, Intracranial Aneurysm, Cerebral Angiography, Cerebrovascular Circulation, Female, Hemodynamics, Humans, Middle Aged, Models, Cardiovascular, Predictive Value of Tests, Prognosis, Radiographic Image Interpretation, Computer-Assisted, Regional Blood Flow, Risk Factors, Stress, Mechanical, Subarachnoid Hemorrhage, Reproducibility of Results, Aneurysm, Ruptured, Risk Assessment, Middle Cerebral Artery, Imaging, Three-Dimensional, Patient-Specific Modeling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiple Aneurysms AnaTomy CHallenge 2018 (MATCH): Phase I: Segmentation. https://app.cochat.ai/papers/10.1007/s13239-018-00376-0
- The paper
- Berg, P., Voß, S., Saalfeld, S., Janiga, G., Bergersen, A. W., Valen-Sendstad, K., Bruening, J., Goubergrits, L., Spuler, A., Cancelliere, N. M., Steinman, D. A., Pereira, V. M., Chiu, T. L., Tsang, A. C. O., Chung, B. J., Cebral, J. R., Cito, S., Pallarès, J., Copelli, G., . . . Beuing, O. (2018). Multiple Aneurysms AnaTomy CHallenge 2018 (MATCH): Phase I: Segmentation. Cardiovascular Engineering and Technology. https://doi.org/10.1007/s13239-018-00376-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.