Abstract

INTRODUCTION: The present study was aimed to evaluate the performance and safety of the Glunovo® real-time continuous glucose monitoring system (CGMS) in monitoring interstitial fluid glucose in adult participants with diabetes (at least 18 years old) using venous blood glucose as control. METHODS: This was a multicenter, self-controlled clinical trial, conducted in participants with diabetes from China, between March 2019 to October 2019. The CGMS was used by all the participants for a 14-day wear-in period. The real-time glucose values measured by Glunovo® CGMS were compared with venous blood glucose values measured by the Entwicklung, Konstruktion und Fertigung (EKF) blood glucose detector. The primary outcomes were the consistency rate of CGMS readings and venous blood glucose values (20/20% standard). RESULTS: A total of 78 participants (41 men, 37 women) and 156 CGMS sensors were included in the study. Among the included participants, 25 and 53 participants had type 1 and type 2 diabetes, respectively, with median age of 52.50 years (range 32-62 years). The overall agreement rate (20/20%) was 89.71% (95% CI 89.18-90.24%). It was observed that 99.08% (95% CI 98.91-99.24%) and 99.82% (95% CI 99.74-99.89%) of the measuring points fell within the A + B zones of the Clarke error grid analysis and Parkes/consensus error grid analysis, respectively. The mean absolute relative difference was 10.30% ± 4.86%. The probability of a glucose measurement falling within a range, when stratified by venous glucose measurements, ranged from 7.14% for 19.44-22.22 mmol/L to 79.21% for 4.44-6.67 mmol/L. There were 73 (41.24%) and 27 (57.45%) successful CGMS alarms for hypoglycemic and hyperglycemic events, respectively. CONCLUSION: From the results, Glunovo® CGMS had excellent accuracy and limited clinical risk compared with venous blood glucose in the range of 2.2-22.2 mmol/L over 14 days.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s13300-021-01171-2

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Error grid analysis of paired sensor–reference values. a Clarke error grid analysis; b Parkes/consensus error grid analysis
Fig. 1 Error grid analysis of paired sensor–reference values. a Clarke error grid analysis; b Parkes/consensus error grid analysisCC BY-NC · PubMed Central
Fig. 2 Kaplan–Meier survival curve of sensor lifetime. The solid red line indicates survival rate; ‘ + ’ represents deletion; shaded region represents 95% CI of survival rate
Fig. 2 Kaplan–Meier survival curve of sensor lifetime. The solid red line indicates survival rate; ‘ + ’ represents deletion; shaded region represents 95% CI of survival rateCC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 11

Metadata

Authors
Meng, R., Gu, T., Yang, F., Liu, J., Sun, Q., & Zhu, D.
Affiliations
Nanjing Drum Tower Hospital (CN)
Corresponding author
Zhu, Dalong
Venue
Diabetes Therapy
Published
2021-10-26
Volume
12
Issue
12
Pages
3153-3165
ISSN
  • 1869-6953 (ISSN-L)
  • 1869-6961
OpenAlex
W3208736085
Cited by
11
References
28
Citations by year
2025: 1 · 2024: 6 · 2023: 3 · 2022: 1
FWCI
1.87
Type
journal article
Language
en
Open access
Licence
Locations
  • Diabetes Therapy (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
continuous glucose monitoring, interstitial glucose, diabetes mellitus, type 1 diabetes, type 2 diabetes, measurement accuracy, Clarke error grid, Chinese patients, device safety, self-controlled trial

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance Evaluation of the Glunovo® Continuous Blood Glucose Monitoring System in Chinese Participants with Diabetes: A Multicenter, Self-Controlled Trial. https://app.cochat.ai/papers/10.1007/s13300-021-01171-2
The paper
Meng, R., Gu, T., Yang, F., Liu, J., Sun, Q., & Zhu, D. (2021). Performance Evaluation of the Glunovo® Continuous Blood Glucose Monitoring System in Chinese Participants with Diabetes: A Multicenter, Self-Controlled Trial. Diabetes Therapy. https://doi.org/10.1007/s13300-021-01171-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.