The DOI matches its Crossref record; 29 of the 30 references it cites were found in a registry or an index.
Real-time continuous glucose monitoring in adults with type 1 diabetes and impaired hypoglycaemia awareness or severe hypoglycaemia treated with multiple daily insulin injections (HypoDE): a multicentre, randomised controlled trial
Abstract
Background The effectiveness of real-time continuous glucose monitoring (rtCGM) in avoidance of hypoglycaemia among high-risk individuals with type 1 diabetes treated with multiple daily insulin injections (MDI) is unknown. We aimed to ascertain whether the incidence and severity of hypoglycaemia can be reduced through use of rtCGM in these individuals. Methods The HypoDE study was a 6-month, multicentre, open-label, parallel, randomised controlled trial done at 12 diabetes practices in Germany. Eligible participants had type 1 diabetes and a history of impaired hypoglycaemia awareness or severe hypoglycaemia during the previous year. All participants wore a masked rtCGM system for 28 days and were then randomly assigned to 26 weeks of unmasked rtCGM (Dexcom G5 Mobile system) or to the control group (continuing with self-monitoring of blood glucose). Block randomisation with 1:1 allocation was done centrally, with the study site as the stratifying variable. Masking of participants and study sites was not possible. Control participants wore a masked rtCGM system during the follow-up phase (weeks 22-26). The primary outcome was the baseline-adjusted number of hypoglycaemic events (defined as glucose ≤3·0 mmol/L for ≥20 min) during the follow-up phase. The full dataset analysis comprised participants who wore the rtCGM system during the baseline and follow-up phases. The intention-to-treat analysis comprised all randomised participants. This trial is registered with ClinicalTria…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“CGM can reveal asymptomatic hypoglycemia and help identify patterns and precipitants of hypoglycemic events and provide alarms that can warn individuals of falling glucose so that they can intervene (150,151).”
From 6. Glycemic Goals, Hypoglycemia, and Hyperglycemic Crises: Standards of Care in Diabetes-2026. (2026) · cites this paper as [150]
In the citing paper
“Several clinical trials have not shown a reduction of IAH by using CGM despite a reduced incidence of level 3 hypoglycemia (101,112,124,126-128).”
In the citing paper
“Hypoglycemia with glucose levels below 3.0 mmol/L (54 mg/dL) occurs much more often than previously appreciated (46,101).”
In the citing paper
“Reductions in HbA1c have been reported with CGM use in people on multiple daily injection (MDI) therapy,19 and continuous subcutaneous insulin infusion therapy,20 with reduced time spent in hypoglycemia,20 and improved hypoglycemia awareness.21”
From Increased Time in Range and Fewer Missed Bolus Injections After Introduction of a Smart Connected Insulin Pen (2020) · cites this paper as [21]
In the citing paper
“The leading CGMs on market today are Dexcom (CA, USA), Medtronic (MN, USA) and Abbott (IL, USA) devices [2-5,19,31].”
From Wearables and the Medical Revolution (2018) · cites this paper as [19]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Self-citationBeck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Hypoglycemia in the Diabetes Control and Complications Trial
The Diabetes Control and Complications Trial Research Group (1997) · Diabetes · doi:10.2337/diab.46.2.271 · Cited by 746
Lind, M., Polonsky, W., Hirsch, I. B., Heise, T., Bolinder, J., Dahlqvist, S., Schwarz, E., Ólafsdóttir, A. F., Frid, A., Wedel, H., et al. (2017) · JAMA · doi:10.1001/jama.2016.19976 · Cited by 705
Clarke, W. L., Cox, D. J., Gonder-Frederick, L. A., Julian, D., Schlundt, D., & Polonsky, W. (1995) · Diabetes Care · doi:10.2337/diacare.18.4.517 · Cited by 651
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
the SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493
Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 Diabetes
Battelino, T., Phillip, M., Bratina, N., Nimri, R., Oskarsson, P., & Bolinder, J. (2011) · Diabetes Care · doi:10.2337/dc10-1989 · Cited by 490
Hypoglycaemia in diabetes mellitus: epidemiology and clinical implications
Frier, B. M. (2014) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2014.170 · Cited by 481
Cited by
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
Self-citation6. Glycemic Targets: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s006 · Cited by 1,403
6. Glycemic Targets: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s006 · Cited by 847
Holt, R. I. G., DeVries, J. H., Hess-Fischl, A., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, E., et al. (2021) · Diabetes Care · doi:10.2337/dci21-0043 · Cited by 699
6. Glycemic Targets: Standards of Care in Diabetes—2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s006 · Cited by 684
Metadata
- Authors
- Heinemann, L., Freckmann, G., Ehrmann, D., Faber-Heinemann, G., Guerra, S., Waldenmaier, D., & Hermanns, N.
- Affiliations
- Universität Ulm (DE)
- Forschungsinstitut der Diabetes Akademie Mergentheim (DE)
- Dexcom (United States) (US)
- Corresponding author
- Hermanns, Norbert
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2018-04
- Volume
- 391
- Issue
- 10128
- Pages
- 1367-1377
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2786804638
- Cited by
- 522
- References
- 30
- Citations by year
- 2026: 33 · 2025: 49 · 2024: 75 · 2023: 65 · 2022: 73 · 2021: 73 · 2020: 62 · 2019: 63 · 2018: 28
- FWCI
- 44.97
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Dexcom
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- real-time continuous glucose monitoring, type 1 diabetes, hypoglycemia, severe hypoglycemia, multiple daily insulin injections, hypoglycemia prevention, self-monitoring of blood glucose, adults with diabetes
- MeSH terms
- Adult, Awareness, Blood Glucose, Diabetes Mellitus, Type 1, Drug Administration Schedule, Female, Follow-Up Studies, Humans, Hypoglycemia, Hypoglycemic Agents, Injections, Subcutaneous, Insulin, Male, Middle Aged, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-time continuous glucose monitoring in adults with type 1 diabetes and impaired hypoglycaemia awareness or severe hypoglycaemia treated with multiple daily insulin injections (HypoDE): a multicentre, randomised controlled trial. https://app.cochat.ai/papers/10.1016/s0140-6736(18)30297-6
- The paper
- Heinemann, L., Freckmann, G., Ehrmann, D., Faber-Heinemann, G., Guerra, S., Waldenmaier, D., & Hermanns, N. (2018). Real-time continuous glucose monitoring in adults with type 1 diabetes and impaired hypoglycaemia awareness or severe hypoglycaemia treated with multiple daily insulin injections (HypoDE): a multicentre, randomised controlled trial. The Lancet. https://doi.org/10.1016/s0140-6736(18)30297-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.